Liqin Chen

Dr. Liqin Chen


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Journal of Chromatography B
Verified
Journal Article
Closed access
Liqin ChenLiqin Chen
Liqin Chen
YTYi Tang
Yi Tang
BXBei Xu
Bei Xu
ZXZhen Xu
Zhen Xu
JSJun Shen
Jun Shen
WZWanqi Zhang
Wanqi Zhang

10 August 2022 in Canadian Journal of Infectious Diseases and Medical Microbiology
Verified
Journal Article
Open access
PDF file
YLYuting Liu
Yuting Liu
Liqin ChenLiqin Chen
Liqin Chen
YDYuping Duan
Yuping Duan
ZXZhen Xu
Zhen Xu
Staphylococci are major hospital-associated pathogens, and the dissemination of methicillin-resistant staphylococci in hospitals poses a great challenge for managing hospital-acquired infections. Little is known about the dissemination of staphylococci recovered from the hospital environment and personnel in China. In this study, antimicrobial susceptibility tests, mecA gene detection, SCCmec typing, and multilocus sequence typing (MLST) were performed to clarify the molecular epidemiology of staphylococci in a large hospital in Tianjin, China. One hundred and ninety-five staphylococci were recovered, and 94 of isolates were resistant to at least one antibiotic. Eighty-five staphylococci were mecA gene-positive, and 40 of them harbored SCCmec IV and V. The genotype of Staphylococcus aureus (S. aureus) was ST25, and the dominant genotype of methicillin-resistant Staphylococcus epidermidis (MRSE) was ST59. Three new sequence types were assigned as ST840, ST841, and ST842. One (2) frequently touched surface was contaminated by S. aureus, which suggested that environmental contamination occurred in the hospital in China. Nineteen (39) frequently touched surfaces were contaminated by methicillin-resistant coagulase-negative staphylococci (MRCoNS), and 46 of HP carried MRCoNS. Varied staphylococcal species and antimicrobial-resistance rates were observed between staphylococci that were recovered from hospital personnel and frequently touched surfaces. The transmission of MRSE and S. aureus between hospital personnel and frequently touched surfaces was detected. Hospital items and personnel may act as reservoirs of antimicrobial-resistant staphylococci, and cleaning strategies should be carried out to decrease the dissemination of antimicrobial-resistant staphylococci in hospitals in China.

ZXZhen Xu
Zhen Xu
Liqin ChenLiqin Chen
Liqin Chen
XCXiaowei Chen
Xiaowei Chen
ATAmei Tang
Amei Tang
DHDengmin Huang
Dengmin Huang
Zhongze FangZhongze Fang
Zhongze Fang
Millions of public shared bicycles (PSBs) have been launched in China, and PSBs are a potential reservoir of antimicrobial-resistant staphylococci. However, no national data to elucidate the dissemination, antimicrobial resistance and genotypes of staphylococci has been recovered from public shared bicycles located in different cities in China. Antimicrobial susceptibility, SCCmec types and sequence types of staphylococci were determined. A total of 146 staphylococci were recovered in this study, and 87% staphylococcal isolates were resistant to at least one antibiotic. In total, 29 (20%) staphylococcal isolates harbored mecA gene, and SCCmec types were determined as follows: SCCmec type II (n = 1), IV(n = 3), V (n = 4), VI (n = 1), VIII (n = 2), A/1 (n = 6), A/5 (n = 2), C/1 (n = 2), C/2 (n = 1), C/3 (n = 1), (n = 5) and Pseudo (ψ)-SCCmec (n = 1). Sequence types of 16 Staphylococcus epidermidis were determined, including ST10, ST17, ST59, ST60, ST65, ST130, ST184, ST262, ST283, ST337, ST360, ST454, ST567, ST820, ST878 and ST934. PSBs are a reservoir of diverse antimicrobial-resistant staphylococci, and staphylococcal species differences were observed in isolates that were recovered from public shared bicycles in the south and north of China. PSBs are a source of antimicrobial resistance and genetic diverse staphylococci.

12 October 2025 in Food Chemistry
Verified
Journal Article
Closed access
YZYuqing Zhao
Yuqing Zhao
ZQZiqian Qin
Ziqian Qin
YWYunyun Wang
Yunyun Wang
Liqin ChenLiqin Chen
Liqin Chen


7 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
TXTong Xu
Tong Xu
RZRui Zhang
Rui Zhang
YBYueling Bi
Yueling Bi
JLJingjing Li
Jingjing Li
XLXiaohuan Li
Xiaohuan Li
Zhongze FangZhongze Fang
Zhongze Fang
Bisphenols (BPs) are a class of endocrine disruptors widely existing in the environment. They have a great impact on human health owing to their environmental endocrine disrupting effects, chronic toxicity, neurotoxicity, cytotoxicity and genetic toxicity. In this paper, an on-line packed fiber solid phase extraction (PFSPE) coupling with column-switching HPLC-FLD determination method was developed for the determination of eight BPs in drinking water. The poly (dibenzo-18-crown-6-ether)/polystyrene composite nanofibers (PDB18C6/PS) were prepared by electrospinning and used as an adsorbent for the on-line PFSPE column. The on-line PFSPE-HPLC equipment contained a dual ternary pump and a switching valve to enable enrichment, purification, and analysis directly in the system. The results showed that the proposed on-line PFSPE-HPLC-FLD method realized the simultaneous separation and detection of eight BPs: BPF, BPE, BPA, BPB, BPAF, BPAP, BPC and BPZ. The curves of the target analytes were prepared with good correlation coefficient values (r2 > 0.998) in the range of 50–1000 pg/mL. The limit of detection (S/N = 3) was 20 pg/mL, the limit of quantitation (S/N = 10) is 50 pg/mL. The recoveries of eight BPs were 94.8–127.3%, and the intra-day precisions (RSD) were less than 10%. The PFSPE column made of the PDB18C6/PS composite nanofibers has stable properties and can be reused at least 200 times. In the detection of drinking water samples, BPZ was detected in nearly 80% of drinking water samples, and BPA, BPAP, BPF and BPAF were also detected in some water samples. This high level of integration and automation was achieved in pretreatment of eight BPs from water samples. The proposed simple, rapid, and practical method has been successfully applied to the detection of eight BPs in drinking water, which can provide powerful technical support for drinking water quality and safety monitoring.