Shivaraj Yellappa

Dr. Shivaraj Yellappa


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Applied Surface Science
Verified
Journal Article
Closed access
MMMallappa Mahanthappa
Mallappa Mahanthappa
NKNagaraju Kottam
Nagaraju Kottam
SYShivaraj Yellappa
Shivaraj Yellappa

1 September 2016 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
MMMallappa Mahanthappa
Mallappa Mahanthappa
SYShivaraj Yellappa
Shivaraj Yellappa
NKNagaraju Kottam
Nagaraju Kottam
CVChiranjeevi Srinivasa Rao Vusa
Chiranjeevi Srinivasa Rao Vusa

19 February 2018 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
MMMallappa Mahanthappa
Mallappa Mahanthappa
NKNagaraju Kottam
Nagaraju Kottam
SYShivaraj Yellappa
Shivaraj Yellappa
The simultaneous electroanalysis of acetaminophen (AC), guanine (G) and adenine (A) was successfully achieved on the zinc sulphide nanoparticles-modified carbon paste electrode (ZnS NPs/CPE) in phosphate buffer solution (PBS). Zinc sulphide nanoparticles (ZnS NPs) were prepared through a simple co-precipitation method and characterized via various spectroscopic techniques. The detailed studies confirmed that the as-synthesized ZnS NPs grew as high-density crystalline structures and they exhibit good electrocatalytic properties. The proposed method is selective and sensitive toward the development of an electrochemical sensor. The modified electrode showed acceptable reproducibility and stability under optimal conditions with high-accessible surface area and antifouling properties. The as-synthesized ZnS NPs enhanced the oxidation peak current and reduced the peak potential of AC, G and A. Furthermore, the sensor showed two linear ranges over the concentration from 1 to 15 μM and 15 to 120 μM. Based on the calibration plot, the limit of detection (LOD) was calculated and found to be 0.041, 0.036 and 0.031 μM for AC, G and A, respectively.

20 June 2017 in Journal of the Chinese Chemical Society
Verified
Journal Article
Closed access
PDF file
RJRamu Jagadish
Ramu Jagadish
SYShivaraj Yellappa
Shivaraj Yellappa
MMMallappa Mahanthappa
Mallappa Mahanthappa
KCKothapalli Bannoth Chandrasekhar
Kothapalli Bannoth Chandrasekhar

11 September 2017 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
MMMallappa Mahanthappa
Mallappa Mahanthappa
MSMohammed Azharuddin Savanur
Mohammed Azharuddin Savanur
BPBijesh Puthusseri
Bijesh Puthusseri
SYShivaraj Yellappa
Shivaraj Yellappa

19 July 2024 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
JRJagadish Ramu
Jagadish Ramu
SRSubramaniyan Ramasundaram
Subramaniyan Ramasundaram
SYShivaraj Yellappa
Shivaraj Yellappa
LGLavanya Gunamalai
Lavanya Gunamalai
TKTapas Kamilya
Tapas Kamilya
Vishwanath R SVishwanath R S
Vishwanath R S
Diabetes mellitus is considered a serious medical issue that is the leading cause of mortality worldwide. Hence, there is a huge demand for developing efficient, reliable, and inexpensive non-enzymatic glucose sensors that can rapidly and accurately monitor glucose levels in physiological fluids. Herein, we developed an efficient and robust Ni/NiO@C composite as an electrocatalyst, which is synthesized via a simple co-precipitation method followed by a controlled annealing treatment. The resulting Ni/NiO@C composite has a spherical structure, yielding the salient features of large surface area, high structural void porosity, accessible surface-active edges, and redox-active centers of Ni2+/Ni3+ which could effectively improve the electrocatalytic oxidation for the detection of glucose. The detailed investigation revealed the electrochemical oxidation of glucose situated at 0.48 V with a wide linear range over the concentration from 0.5 μM to 2.0 mM. Based on the calibration plot, the limit of detection (LOD) and sensitivity were calculated to be 0.061 μM, and 9.73 μA cm−2 μM−1, respectively. The designed sensor's electroanalytical performance was effectively validated for the investigation of target species in actual samples. This work offers insights into the synergistic electrocatalytic activity of precious metal and enzyme-free catalysts for use in clinical diagnostics for the analysis of glucose molecules.