Marcel Elias Zughaib

Marcel Elias Zughaib


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2018 in Cardiology Research and Practice
Verified
Journal Article
Open access
PDF file
STSunit Tolia
Sunit Tolia
ZKZubair Khan
Zubair Khan
GGGunjan Gholkar
Gunjan Gholkar
MZMarcel Elias Zughaib
Marcel Elias Zughaib
Background. Routine ambulatory echocardiographic estimates of left ventricular (LV) filling pressures are not cost-effective and are occasionally fraught with anatomic, physiologic as well as logistical limitations. The use of implantable hemodynamic devices such as CardioMEMS Heart Failure (HF) System has been shown to reduce HF-related readmission rates by remote monitoring of LV filling pressures. Little is known about the correlation between CardioMEMS and echocardiography-derived estimates of central hemodynamics. Methods. We performed a prospective, single-center study enrolling seventeen participants with New York Heart Association functional class II-III HF and preimplanted CardioMEMS sensor. Simultaneous CardioMEMS readings and a limited echocardiogram were performed at individual clinic visits. Estimated left atrial pressure (LAP) by echocardiogram was calculated by the Nagueh formula. Linear regression was used as a measure of agreement. Variability between methods was evaluated by Bland–Altman analysis. Results. Mean age was 74 ± 9 years; 59% (10/17) were males. LV systolic dysfunction was present in 76% (13/17) of subjects. Mean PAdP was 18 ± 4 mmHg and 19 ± 5 mmHg for CardioMEMS and echocardiographic-derived estimates, respectively, with a significant correlation between both methods (r2=0.798,  p≤0.001). Conclusions. Our study illustrates a direct linear correlation between PAdP measured by CardioMEMS and simultaneous measurement of LV filling pressures derived by echocardiography.

28 May 2018 in Journal of International Medical Research
Verified
Journal Article
Open access
MAMahmoud Assaad
Mahmoud Assaad
RSRobby Singh
Robby Singh
SSSinan Sarsam
Sinan Sarsam
ABAbbie Bowen
Abbie Bowen
MZMarcel Elias Zughaib
Marcel Elias Zughaib
Introduction: Congestive heart failure is a leading cause of cardiovascular mortality and morbidity in the United States and places a significant economic burden on the health care system. The CHAMPION trial showed significant reductions in heart failure hospitalizations and length of stay as well as improvements in quality of life among patients who underwent implantation of the CardioMEMS device (CardioMEMS Inc., Atlanta, GA, USA). While the benefits of the device have been well demonstrated, we explored the “pseudo-placebo” effect of device placement on patients’ lifestyle modifications. Methods: Thirty patients with the CardioMEMS device were contacted for a follow-up survey that included questions about lifestyle modifications, symptomatic and dietary improvement, increased physical activity, and changes in their cardiac medication regimen. Results: Dyspnea improved in 57% of patients, 70% of patients improved their diet, and 43% increased their physical activity. Only 7% of patients found it difficult to transmit the data. Discussion: The CHAMPION trial showed numerous benefits for patients who underwent CardioMEMS device placement. In our study, we found that device placement also resulted in a “pseudo-placebo” effect with most patients making positive lifestyle modifications.

11 February 2020 in Case Reports in Cardiology
Verified
Journal Article
Open access
PDF file
RSRobby Singh
Robby Singh
SSSanto Scarfone
Santo Scarfone
MZMarcel Elias Zughaib
Marcel Elias Zughaib
Introduction. Cardiovascular disease is a leading cause of morbidity and mortality with heart failure constituting a large portion of this spectrum. Heart failure patients have 90-day readmission rates of nearly 41% associated with a high expense. Numerous strategies to reduce readmissions have been attempted with the CardioMEMS pulmonary artery pressure monitoring system as one of the more successful ones. As this device becomes used more frequently, it is important to recognize procedural complications. We present of a rare complication where a patient underwent successful device placement and was subsequently found to have dampened waveforms which were due to device migration. Case Report. A 79-year-old male underwent successful CardioMEMS placement due to recurrent heart failure hospitalizations. 6 months later, the transmitted waveforms appeared dampened, and repeat angiography revealed a device that had migrated. Rather than abandoning the device, it was recalibrated and continued to transmit data and helped manage the patient’s heart failure. Conclusion. CardioMEMS is a cost-effective tool to help reduce heart failure hospitalizations. Device migration is a rare complication and can lead to inaccurate data. However, as seen in this case, the device can be successfully recalibrated and can continue to be utilized to help reduce heart failure admissions.

1 January 2016 in International Journal of Cardiology
Verified
Journal Article
Closed access
BPBrijesh Patel
Brijesh Patel
MAMahmoud Assaad
Mahmoud Assaad
STSunit Tolia
Sunit Tolia
MBMuhammad Bajwa
Muhammad Bajwa
MZMarcel Elias Zughaib
Marcel Elias Zughaib

23 October 2019 in Cardiology Research and Practice
Verified
Journal Article
Open access
PDF file
RSRobby Singh
Robby Singh
MNMoumita Naidu
Moumita Naidu
YBYousef Bader
Yousef Bader
DFDavid Freeman
David Freeman
MZMarcel Elias Zughaib
Marcel Elias Zughaib
Background. Transesophageal echocardiogram (TEE) is a valuable tool in healthcare today with its ease of use, ability to visualize important structures not seen on transthoracic echocardiogram (TTE), and the relatively lower cost of TEE, high yield, and no significant radiation exposure. The American Society of Echocardiography (ASE) has developed an appropriate use criteria for use of TTE and TEE, which outline various scenarios where a TEE is indicated as an initial diagnostic testing modality and when it is useful as an adjunctive test in hopes of decreasing inappropriate use. Using these criteria as a guide, we devised a quality assessment study to investigate how well TEEs performed at our institution fit the appropriate use criteria specifically for the diagnostic workup of infective endocarditis. Methods. A retrospective chart review was performed for all TEEs performed in 2017 with the indication of endocarditis. Baseline patient characteristics, presence of bacteremia, and the quality of the TTE preceding the TEE were noted, as well as whether a vegetation, abscess, or perforation was visualized. We also determined if there was a cardiology consultation placed prior to TEE and if the patient had met the definition for endocarditis as defined by the Duke criteria. Finally, we made note of the TEE findings and assessed whether the TEE met appropriate use criteria developed by the American Society of Echocardiography. Results. A total of 50 patients who underwent TEE with the indication of “endocarditis” were identified. 36% of the TTEs prior to the TEE were rated as good quality, 40% as adequate, 4% as fair, 4% as suboptimal, 12% as technically difficult, and 4% were not rated. Vegetations were visualized on 12% of TTEs, 6% of patients had a prosthetic valve, and 6% had a cardiac device. In 20% of the cases, there was no cardiology consultation prior to the TEE and in 20% of the cases, there was no documented bacteremia. 26% of patients met the Duke criteria for endocarditis prior to TEE. Only 36% of TEEs revealed evidence of infection and of the patients with no evidence of infection, only 38% met appropriate use criteria. Overall, only 56% of patients met appropriate use criteria for TEE. Conclusion. Transesophageal echocardiography is a valuable tool in a modern physician’s arsenal for managing a variety of diseases and conditions. However, the procedure is not without associated risks and its ease of use and widespread adoption has led to frequent questionable appropriateness of use of the test. Only 56% of the TEEs performed in our analysis met appropriate use. More awareness and education is needed for the appropriate use criteria for transesophageal echocardiography as outlined by the ASE to help reduce patient exposure to procedure related complications and to decrease medical costs on unnecessary procedures.

15 January 2019 in Cardiology Research and Practice
Verified
Journal Article
Open access
PDF file
RSRobby Singh
Robby Singh
MZMarcel Elias Zughaib
Marcel Elias Zughaib
Background. As the number of procedures using contrast media continues to rise, the ensuing complications place an ever increasing burden on the healthcare system. Contrast-induced nephropathy (CIN) is a common postprocedural complication after cardiac catheterization. Objectives. The purpose of our study was to evaluate the impact of physician behavioral modification on reducing the amount of contrast used during the procedure. Methods. All patients who underwent procedures in the cardiac catheterization laboratory from January 2013 to August 2016 were identified in addition to the total contrast used during the procedure, the type of procedure performed, and the operator performing the procedure. A new addition was made to the preprocedure checklist in September-October 2013 in the form of maximum allowed contrast for the patient. Results. A total of 12,118 cases were identified. Across all procedures, the mean contrast used during the 8 months prior to the intervention was 118 ml per procedure. Mean contrast used per procedure for the first year after the revised timeout was 105 ml, for the second year was 106 ml, and for the third year was 99 ml. Conclusion. A significant reduction in radiocontrast use across all operators and procedures after the introduction of a revised timeout procedure that was seen, which is a change that was sustained over a period of three years. With this straightforward intervention involving physician behavioral modification, patients were exposed to less of the nephrotoxic contrast and were consequently at a lower risk of developing dose-depended CIN and other associated complications.