Vitaliy Atamaniuk

Mr. Vitaliy Atamaniuk

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2024 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
VAVitaliy Atamaniuk
Vitaliy Atamaniuk
ŁHŁukasz Hańczyk
Łukasz Hańczyk
JCJun Chen
Jun Chen
APAndrii Pozaruk
Andrii Pozaruk
MOMarzanna Obrzut
Marzanna Obrzut
BOBogdan Obrzut
Bogdan Obrzut

23 August 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MOMarzanna Obrzut
Marzanna Obrzut
VAVitaliy Atamaniuk
Vitaliy Atamaniuk
RERichard L. L Ehman
Richard L. L Ehman
MYMeng Yin
Meng Yin
MCMarian Cholewa
Marian Cholewa
Bogdan ObrzutBogdan Obrzut
Bogdan Obrzut
Purpose: Magnetic resonance elastography (MRE) has been established as the most accurate noninvasive technique for diagnosing liver fibrosis. Recent publications have suggested that the measurement of splenic stiffness is useful in setting where portal hypertension may be present. The goal of the current study was to compile normative data for MRE-assessed stiffness measurements of the spleen in young adults. Materials and Methods: A total of 100 healthy young Caucasian volunteers (65 females and 35 males) in the age range of 20 to 32 years were enrolled in this study. The participants reported no history of chronic spleen and liver disease, normal alcohol consumption, and a normal diet. The MRE data were acquired by using a 1.5 T whole-body scanner and a 2D GRE pulse sequence with 60 Hz excitation. Spleen stiffness was calculated as a weighted mean of stiffness values in the regions of interest manually drawn by the radiologist on three to five spleen slices. Results: Mean spleen stiffness was 5.09 ± 0.65 kPa for the whole group. Male volunteers had slightly higher splenic stiffness compared to females: 5.28 ± 0.78 vs. 4.98 ± 0.51 kPa, however, this difference was not statistically significant (p = 0.12). Spleen stiffness did not correlate with spleen fat content and liver stiffness but a statistically significant correlation with spleen volume was found. Conclusions: The findings of this study provide normative values for 2D MRE-based measurement of spleen stiffness in young adults, a basis for assessing the value of this biomarker in young patients with portal system pathologies.

18 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VAVitaliy Atamaniuk
Vitaliy Atamaniuk
JCJun Chen
Jun Chen
MOMarzanna Obrzut
Marzanna Obrzut
KGKevin J. Glaser
Kevin J. Glaser
ŁHŁukasz Hańczyk
Łukasz Hańczyk
MCMarian Cholewa
Marian Cholewa
Parotid glands are one of the most common sites for salivary gland tumors. Conventional imaging techniques have limited usefulness in the quantitative assessment of the parotid glands, making it difficult to differentiate between healthy tissue and tumors, as well as between benign and malignant tumors. Magnetic resonance elastography (MRE) is a non-invasive technique that may potentially overcome these limitations. Nevertheless, due to the size of the parotid gland, increased elastographic resolution is required. This may be achieved by applying shear waves at higher frequencies. However, it also results in stronger attenuation, making the illumination of the parotid challenging. Here, we describe a novel passive driver tailored to the anatomy of the human face, which minimizes the distance shear waves need to travel from the source to the area of interest and thus decreases shear wave attenuation, making high-frequency shear wave MRE feasible.

9 March 2026 in NMR in Biomedicine
Verified
Journal Article
Closed access
VAVitaliy Atamaniuk
Vitaliy Atamaniuk
APAndrii Pozaruk
Andrii Pozaruk
MMMichał Madera
Michał Madera
MWMikołaj Wcisło
Mikołaj Wcisło
BOBogdan Obrzut
Bogdan Obrzut
MOMarzanna Obrzut
Marzanna Obrzut

9 October 2023 in NMR in Biomedicine
Verified
Journal Article
Closed access
MOMarzanna Obrzut
Marzanna Obrzut
VAVitaliy Atamaniuk
Vitaliy Atamaniuk
RERichard L. Ehman
Richard L. Ehman
MYMeng Yin
Meng Yin
MCMarian Cholewa
Marian Cholewa
BOBogdan Obrzut
Bogdan Obrzut

Verified
Journal Article
Open access
PDF file
APAndrii Pozaruk
Andrii Pozaruk
VAVitaliy Atamaniuk
Vitaliy Atamaniuk
KPKamlesh Pawar
Kamlesh Pawar
ACAlexandra Carey
Alexandra Carey
JCJeremy Cheng
Jeremy Cheng
GEGary F Egan
Gary F Egan
This study evaluated the hypothesis that 68Ga-PSMA-11 PET SUV, obtained via an advanced DL approach, correlates better with MR ADC maps than values from conventional PET-MR. Additionally, we aimed to identify the optimal SUV threshold for maximum correlation with ADC values. A cohort of 32 prostate cancer patients underwent CT and corresponding PET-MR imaging. The dataset underwent K-fold cross-validation, dividing it into four folds. In each fold, 24 patients were used for training, and 8 for validation to create DL models. ADC maps from 27 out of 32 patients were successfully aligned with T2 images for detailed analysis, revealing an inverse correlation (ρ = −0.20 to −0.51) between ADC and SUV values in prostate cancer zones. Statistically significant differences in mean SUV values were observed between PETMRI and PETDL. DL-based SUV values show a stronger correlation with ADC than conventional PET-MR values in our investigation.