Honda Hsu

Dr. Honda Hsu


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
CCChien-Hwa Chang
Chien-Hwa Chang
CHChieh-Chi Huang
Chieh-Chi Huang
HHHonda Hsu
Honda Hsu
CLChih-Ming Lin
Chih-Ming Lin
SHShih-Ming Huang
Shih-Ming Huang

27 October 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
HHHonda Hsu
Honda Hsu
KLKun-Hua Lee
Kun-Hua Lee
Riya KarmakarRiya Karmakar
Riya Karmakar
Arvind MukundanArvind Mukundan
Arvind Mukundan
RARehan Samirkhan Attar
Rehan Samirkhan Attar
Hsiang-Chen WangHsiang-Chen Wang
Hsiang-Chen Wang
Background/Objectives: Breast cancer (BC) has emerged as a significant threat among female malignancies, resulting in approximately 670,000 fatalities. The capacity to identify BC has advanced over the past two decades because of deep learning (DL), machine learning (ML), and artificial intelligence. The early detection of BC is crucial; yet, conventional diagnostic techniques, including MRI, mammography, and biopsy, are costly, time-intensive, less sensitive, incorrect, and necessitate skilled physicians. This narrative review will examine six novel imaging approaches for BC diagnosis. Methods: Optical coherence tomography (OCT) surpasses existing approaches by providing non-invasive, high-resolution imaging. Raman Spectroscopy (RS) offers detailed chemical and structural insights into cancer tissue that traditional approaches cannot provide. Photoacoustic Imaging (PAI) provides superior optical contrast, exceptional ultrasonic resolution, and profound penetration and visualization capabilities. Hyperspectral Imaging (HSI) acquires spatial and spectral data, facilitating non-invasive tissue classification with superior accuracy compared to grayscale imaging. Contrast-Enhanced Spectral Mammography (CESM) utilizes contrast agents and dual energy to improve the visualization of blood vessels, enhance patient comfort, and surpass standard mammography in sensitivity. Multispectral Imaging (MSI) enhances tissue classification by employing many wavelength bands, resulting in high-dimensional images that surpass the ultrasound approach. The imaging techniques studied in this study are very useful for diagnosing tumors, staging them, and guiding surgery. They are not detrimental to morphological or immunohistochemical analysis, which is the gold standard for diagnosing breast cancer and determining molecular characteristics. Results: These imaging modalities provide enhanced sensitivity, specificity, and diagnostic accuracy. Notwithstanding their considerable potential, the majority of these procedures are not employed in standard clinical practices. Conclusions: Validations, standardization, and large-scale clinical trials are essential for the real-time application of these approaches. The analyzed studies demonstrated that the novel modalities displayed enhanced diagnostic efficacy, with reported sensitivities and specificities often exceeding those of traditional imaging methods. The results indicate that they may assist in early detection and surgical decision-making; however, for widespread adoption, they must be standardized, cost-reduced, and subjected to extensive clinical trials. This study offers a concise summary of each methodology, encompassing the methods and findings, while also addressing the many limits encountered in the imaging techniques and proposing solutions to mitigate these issues for future applications.

1 October 2014 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
CHChieh-Chi Huang
Chieh-Chi Huang
CCChien-Hwa Chang
Chien-Hwa Chang
HHHonda Hsu
Honda Hsu
CCChih-Hung Mark Chiu
Chih-Hung Mark Chiu
CLChih-Ming Lin
Chih-Ming Lin
SCSou-Hsin Chien
Sou-Hsin Chien

23 April 2014 in Microsurgery
Verified
Journal Article
Closed access
PDF file
JLJiunn‐Tat Lee
Jiunn‐Tat Lee
PCPeir‐Rong Chen
Peir‐Rong Chen
HHHonda Hsu
Honda Hsu
MWMeng‐Si Wu
Meng‐Si Wu
LCLi‐Fu Cheng
Li‐Fu Cheng
SCSou‐Hsin Chien
Sou‐Hsin Chien

1 December 2012 in Annals of Plastic Surgery
Verified
Journal Article
Closed access
HHHonda Hsu
Honda Hsu
SCSou-Hsin Chien
Sou-Hsin Chien
CWChien-Hsing Wang
Chien-Hsing Wang
LCLi-Fu Cheng
Li-Fu Cheng
CLChih Lin
Chih Lin
JLJiunn-Tat Lee
Jiunn-Tat Lee
We describe our experience in expanding the use of pedicled anterolateral thigh and vastus lateralis myocutaneous flaps. A total of 33 patients underwent 34 flaps between March 2003 and January 2012. The defects included 18 ischial, 3 trochanteric, 5 lower abdomen, 2 perineogenital, 1 groin, and 5 knee defects. There were 29 proximal pedicled (2 of which were preexpanded), 3 distal pedicled, and 2 propeller flaps. Complications included 1 total necrosis, 1 partial necrosis, 3 wound dehiscence in recipient site, 1 hematoma, and 1 donor-site dehiscence. The total flap survival rate was 94%. There were no donor-site morbidities except poor cosmesis in the skin-grafted sites. Pedicled anterolateral thigh flap is highly versatile with a wide arc of rotation. A proximal pedicled flap can be used for lower abdomen, perineogenital, ischial, and trochanteric defects and the distal pedicled or a propeller flap for knee and proximal lower leg defects.

1 June 2018 in Annals of Plastic Surgery
Verified
Journal Article
Closed access
YYYa-Hui Msc Yen
Ya-Hui Msc Yen
CLChih-Ming Lin
Chih-Ming Lin
HHHonda Hsu
Honda Hsu
YCYing-Chen Bsc Chen
Ying-Chen Bsc Chen
WLWan-Yu Bsc Li
Wan-Yu Bsc Li
CHChieh-Chi Huang
Chieh-Chi Huang
Background The traditional method of skin graft fixation is with tie-over bollus dressing. The use of splints in the extremities for skin graft fixation is a common practice. However, these splints are heavy and uncomfortable and contribute considerably to our overall medical waste. Hydrofiber (Aquacel® Extra) has a strong fluid absorption property and fixates well to the underlying wound once applied. In this study, we used hydrofiber for fixation, avoiding the use of splints after skin grafting. Methods A total of 56 patients reconstructed with split-thickness skin graft that was fixated only with hydrofiber between March 2015 and March 2016 were included in this retrospective study. Results There were 44 men and 12 women with a mean age of 61 ± 18 years. The defect size ranged from 1 × 1 cm for fingertips to 30 × 12 cm for lower limb defects. The average defect size was 61 ± 78 cm2. The mean skin graft take was 96% ± 6%. Because splints were not required, we saved around 48 kg of medical waste over the space of 1 year. Conclusions The use of hydrofiber for skin graft fixation was effective and technically very simple. Splints were not required with this method, decreasing the medical waste created and increasing patient comfort. We suggest that this is an excellent alternative for skin graft fixation while at the same time decreasing our carbon footprint as surgeons.