The new postoperative free flap monitoring system combines visible-light and infrared techniques to overcome the limitations of our previous study, such as resistance to illumination change, patients with large movements, and the infrared images being too blurry to identify the boundary. In the visible-light system, the Mask region-based convolutional neural networks (RCNN) was adopted to segment the region of the free flap, and these time-course visible images were aligned using our proposed image registration method. Then, the registered visible images were projected onto the infrared image by the coordinate transformation. The analysis method adopted the residual factor analysis to extract the more unvarnished specific factors. The experiments were divided into two parts. In image processing, the accuracy of the coordinate transformation has a mean error of 1.78 pixels and a standard deviation of 0.98 pixels. The segmentation results showed excellent performance in the most severe case with apparent motion and rotation, covered by gauze and the ventilator, as well as illumination variation. The dice coefficient is 0.9551 ± 0.0158, and the Hausdorff distance is 2.3943 ± 0.3921 pixels. The image registration results also reveal that the Canny edge of the deformed image was superimposed onto the reference image well. In circulatory compromise detection, the vascular congestion was detected much earlier than manual observation, and the classified type of occlusion was the same as the clinical reports. Therefore, the dual-camera monitoring system provides a reliable tool for the surgeon to hold onto the chance of repairing the free flap with vascular obstruction.
Microvascular free flap surgery has been a reliable reconstruction method, but some flaps may have circulatory compromise within five to seven days of surgery. Besides, many auxiliary devices are expensive and complex to operate. Therefore, most of the medical personnel still use the manual observation. To decrease heavy workload on medical personnel, the monitoring system was developed to analyze the color variation of free flap by a visible-light camera with advantages such as fast operation, low cost, noninvasive behavior, and contactless and nonradiative operation would be also needed for patients. The proposed system was mainly comprised of a longitudinal image registration without markers and a circulatory compromise detection, which were aiming to reduce the deformation from patients’ motion and eliminate the influence of illumination variation from the surrounding, respectively. In the clinical trial, the performance assessment of image registration reveals that the average and the standard variation of dice similarity coefficient (DSC) can reach 0.959 and 0.011, respectively. The relationship among the situation of blood perfusion and the results of circulatory compromise detection at flap was summarized and shown that the detection system not only determined the moment of vascular occlusion but also the type of occlusion. In addition, vascular congestion was even detected much earlier than manual observation. Therefore, our monitoring system is expected to relieve the workload on medical personnel and could be a reliable tool for the surgeon to hold onto the chance of repairing the free flap with vascular obstruction.
19 February 2025 in Expert Systems with Applications
The automated marker-free longitudinal Infrared (IR) breast image registration overcomes several challenges like no anatomic fiducial markers on the body surface, blurry boundaries, heat pattern variation by environmental and physiological factors, nonrigid deformation, etc, has the ability of quantitative pixel-wise analysis with the heat energy and patterns change in a time course study. To achieve the goal, scale-invariant feature transform, Harris corner, and Hessian matrix were employed to generate the feature points as anatomic fiducial markers, and hybrid genetic algorithm and particle swarm optimization minimizing the matching errors was used to find the appropriate corresponding pairs between the 1st IR image and the n th IR image. Moreover, the mechanism of the IR spectrogram hardware system has a high level of reproducibility. The performance of the proposed longitudinal image registration system was evaluated by the simulated experiments and the clinical trial. In the simulated experiments, the mean difference of our system is 1.64 mm, which increases 57.58% accuracy than manual determination and makes a 17.4% improvement than the previous study. In the clinical trial, 80 patients were captured several times of IR breast images during chemotherapy. Most of them were well aligned in the spatiotemporal domain. In the few cases with evident heat pattern dissipation and spatial deviation, it still provided a reliable comparison of vascular variation. Therefore, the proposed system is accurate and robust, which could be considered as a reliable tool for longitudinal approaches to breast cancer diagnosis.
The automated marker-free longitudinal Infrared (IR) breast image registration overcomes several challenges like no anatomic fiducial markers on the body surface, blurry boundaries, heat pattern variation by environmental and physiological factors, nonrigid deformation etc., has the ability of quantitative pixel-wise analysis with the heat energy and patterns change in a time course study. To achieve the goal, Scale invariant feature transform (SIFT), Harris corner and Hessian matrix were employed to generate the feature points as anatomic fiducial markers, and hybrid genetic algorithm and particle swarm optimization (GA-PSO) minimizing the matching errors was used to find the appropriate corresponding pairs between the 1st IR image and the nth IR image. Moreover, the mechanism of the IR spectrogram hardware system has a high level of reproducibility. The performance of proposed longitudinal image registration system was evaluated by the simulated experiments and the clinical trial. In the simulated experiments, the mean difference of our system is 1.64 mm, which increases 57.58% accuracy than manual determination and makes 17.4% improvement than the previous study. In the clinical trial, 80 patients were captured several times of IR breast images during chemotherapy. Most of them were well aligned in the spatiotemporal domain. In the few cases with evident heat pattern dissipation and spatial deviation, it still provided the reliable comparison of vascular variation. Therefore, the proposed system is accurate and robust, which could be considered as a reliable tool for longitudinal approaches of breast cancer diagnosis.
28 August 2024 in Computer Methods and Programs in Biomedicine