Nathawut Choengchan

Dr. Nathawut Choengchan


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Talanta
Verified
Journal Article
Closed access
AMArjnarong Mathaweesansurn
Arjnarong Mathaweesansurn
STSuthathip Thongrod
Suthathip Thongrod
PKPutthiporn Khongkaew
Putthiporn Khongkaew
CPChutima Matayatsuk Phechkrajang
Chutima Matayatsuk Phechkrajang
PWPrapin Wilairat
Prapin Wilairat
NCNathawut Choengchan
Nathawut Choengchan

1 October 2006 in Analytica Chimica Acta
Verified
Journal Article
Closed access
NCNathawut Choengchan
Nathawut Choengchan
TMT. Mantim
T. Mantim
PWP. Wilairat
P. Wilairat
PDP.K. Dasgupta
P.K. Dasgupta
SMS. Motomizu
S. Motomizu
DND. Nacapricha
D. Nacapricha

1 January 2021 in Talanta
Verified
Journal Article
Closed access
ALAurachat Lert-Itthiporn
Aurachat Lert-Itthiporn
PSPongpichet Srikritsadawong
Pongpichet Srikritsadawong
NCNathawut Choengchan
Nathawut Choengchan

1 February 2015 in Talanta
Verified
Journal Article
Closed access
NCNathawut Choengchan
Nathawut Choengchan
TMT. Mantim
T. Mantim
PIP. Inpota
P. Inpota
DND. Nacapricha
D. Nacapricha
PWP. Wilairat
P. Wilairat
NMNoppawan Phumala Morales
Noppawan Phumala Morales

1 February 2018 in Analytical Sciences
Verified
Journal Article
Closed access
PDF file
PIPrawpan Inpota
Prawpan Inpota
KSKamil Strzelak
Kamil Strzelak
RKRobert Koncki
Robert Koncki
WSWisaroot Sripumkhai
Wisaroot Sripumkhai
WJWutthinan Jeamsaksiri
Wutthinan Jeamsaksiri
DNDuangjai Nacapricha
Duangjai Nacapricha
A microfluidic method with front-face fluorometric detection was developed for the determination of total inorganic iodine in drinking water. A polydimethylsiloxane (PDMS) microfluidic device was employed in conjunction with the Sandell-Kolthoff reaction, in which iodide catalyzed the redox reaction between Ce(IV) and As(III). Direct alignment of an optical fiber attached to a spectrofluorometer was used as a convenient detector for remote front-face fluorometric detection. Trace inorganic iodine (IO3- and I-) present naturally in drinking water was measured by on-line conversion of iodate to iodide for determination of total inorganic iodine. On-line conversion efficiency of iodate to iodide using the microfluidic device was investigated. Excellent conversion efficiency of 93 - 103% (%RSD = 1.6 - 11%) was obtained. Inorganic iodine concentrations in drinking water samples were measured, and the results obtained were in good agreement with those obtained by an ICP-MS method. Spiked sample recoveries were in the range of 86%(+/- 5) - 128%(+/- 8) (n = 12). Interference of various anions and cations were investigated with tolerance limit concentrations ranging from 10(-6) to 2.5 M depending on the type of ions. The developed method is simple and convenient, and it is a green method for iodine analysis, as it greatly reduces the amount of toxic reagent consumed with reagent volumes in the microfluidic scale.

10 February 2018 in Analytical Sciences
Verified
Journal Article
Closed access
PDF file
NCNathawut Choengchan
Nathawut Choengchan
BPBangerdsuk Poontong
Bangerdsuk Poontong
AMArjnarong Mathaweesansurn
Arjnarong Mathaweesansurn
NMNoppadol Maneerat
Noppadol Maneerat
SMShoji Motomizu
Shoji Motomizu
DNDuangjai Nacapricha
Duangjai Nacapricha
A new design of membraneless gas-diffusion unit with dual acceptor channels for separation, collection and simultaneous determination of two volatile analytes in liquid sample is presented. The unit is comprised of three parallel channels in a closed module. A sample is aspirated into the central channel and two kinds of reagents are introduced into the other two channels. Two analytes are isolated from the sample matrix by diffusion into head-space and absorbed into the specific reagents. Non-absorbed vapor is released by opening the programmable controlled lid. The unit was applied to liquors for measurement of ethanol and acetaldehyde using reverse flow injection. Dichromate and nitroprusside were exploited as reagents for colorimetric detection of ethanol and acetaldehyde, respectively. Good linearity ranges (r2 >0.99) with high precision (RSD <2%) and high accuracy (recovery: 90 – 105%) were achieved. The results were compared to the results by GC-FID and no significant difference was observed by paired t-test (95% confidence).