Fernando Sebastian-Valles

Dr. Fernando Sebastian-Valles

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2020 in Nutrients
Verified
Journal Article
Open access
PDF file
ECElena Carrillo
Elena Carrillo
FSFernando Sebastian-Valles
Fernando Sebastian-Valles
CTCarolina Knott Torcal
Carolina Knott Torcal
MicroRNAs (MiRNAs) are small RNA molecules that can exert regulatory functions in gene expression. MiRNAs have been identified in diverse tissues and biological fluids, both in the context of health and disease. Breastfeeding has been widely recognized for its superior nutritional benefits; however, a number of bioactive compounds have been found to transcend these well-documented nutritional contributions. Breast milk was identified as a rich source of miRNAs. There has been increasing interest about their potential ability to transfer to the offspring as well as what their specific involvement is within the benefits of breast milk in the infant. In comparison to breast milk, formula milk lacks many of the benefits of breastfeeding, which is thought to be a result of the absence of some of these bioactive compounds. In recent years, the miRNA profile of breast milk has been widely studied, along with the possible transfer mechanisms throughout the infant’s digestive tract and the role of miRNA-modulated genes and their potential protective and regulatory functions. Nonetheless, to date, the current evidence is not consistent, as many methodological limitations have been identified; hence, discrepancies exits about the biological functions of miRNAs. Further research is needed to provide thorough knowledge in this field.

25 January 2024 in BMC Medicine
Verified
Journal Article
Open access
PDF file
FSFernando Sebastian-Valles
Fernando Sebastian-Valles
JMJulia Martínez-Alfonso
Julia Martínez-Alfonso
JMJose Alfonso Arranz Martin
Jose Alfonso Arranz Martin
JJJessica Jiménez-Díaz
Jessica Jiménez-Díaz
IAIñigo Hernando Alday
Iñigo Hernando Alday
MMMónica Marazuela
Mónica Marazuela
Background: This study investigates the association between socioeconomic status (SES) and glycemic control in individuals with type 1 diabetes (T1D) using flash glucose monitoring (FGM) devices within a public health system where these technologies are freely available and utilized according to recommended guidelines. Methods: A follow-up study of 1060 adults (mean age 47.4 ± 15.0 years, 49.0% women) with T1D, receiving care at three Spanish university hospitals that regularly employ the FGM system. SES was assessed using the Spanish Deprivation Index and the average annual net income per person. Glycemic data were collected over a 14-day follow-up period, including baseline glycated hemoglobin (HbA1c) levels prior to sensor placement, the last available HbA1c levels, and FGM-derived glucose metrics. Individuals with sensor usage time < 70% were excluded. Chronic micro and macrovascular complications related to diabetes were documented. Regression models, adjusted for clinical variables, were employed to determine the impact of SES on optimal sensor control (defined as time in range (TIR) ≥ 70% with time below range < 4%) and disease complications. Results: The average follow-up was of 2 years. The mean TIR and the percentage of individuals with optimal control were higher in individuals in the highest SES quartile (64.9% ± 17.8% and 27.9%, respectively) compared to those in the lowest SES quartile (57.8 ± 17.4% and 12.1%) (p < 0.001). Regression models showed a higher risk of suboptimal control (OR 2.27, p < 0.001) and ischemic heart disease and/or stroke (OR 3.59, p = 0.005) in the lowest SES quartile. No association was observed between SES and the risk of diabetic nephropathy and retinopathy. FGM system improved HbA1c levels across all SES quartiles. Although individuals in the highest SES quartile still achieved a significantly lower value at the end of the follow-up 55 mmol/mol (7.2%) compared to those in the lowest SES quartile 60 mmol/mol (7.6%) (p < 0.001), the significant disparities in this parameter between the various SES groups were significantly reduced after FGM technology use. Conclusions: Socioeconomic status plays a significant role in glycemic control and complications in individuals with T1D, extending beyond access to technology and its proper utilization. The free utilization of FGM technology helps alleviate the impact of social inequalities on glycemic control.

27 May 2024 in Pediatric Diabetes
Verified
Journal Article
Open access
PDF file
MRMarta Carolina Ruiz-Grao
Marta Carolina Ruiz-Grao
Ana Díez-FernandezAna Díez-Fernandez
Ana Díez-Fernandez
AMArthur Eumann Mesas
Arthur Eumann Mesas
Vicente Martinez VizcainoVicente Martinez Vizcaino
Vicente Martinez Vizcaino
ISIrene Sequí-Domínguez
Irene Sequí-Domínguez
MGMiriam Garrido-Miguel
Miriam Garrido-Miguel
Aim. To assess the incidence trends in type 1 diabetes among children and adolescents across Europe during the period from 1994 to 2022 using a systematic methodology. Materials and Methods. Cross-sectional or follow-up studies reporting population-based incidence rates (IRs) of European children and adolescents diagnosed aged <15 years with type 1 diabetes were included. The Mantel‒Haenszel or DerSimonian and Laird random-effects method was used to compute the pooled IR estimates and their 95% confidence intervals (CIs). Subgroup analyses were conducted by study year, biological sex, age group (0–4, 5−9, and 10–14 years), country, and European regions. Results. A total of 75 studies (219,331 children and adolescents aged 0–14 years) with data from 32 countries were included. Generally, a high overall rate of increase in type 1 diabetes incidence has been shown in most European countries from 1994 to 2022 in both sexes, with an overall increase from 10.85 (95% CI, 9.62–12.07) per 100,000 person-years from 1994 to 2003 to 20.96 (95% CI, 19.26–22.66) per 100,000 person-years from 2013 to 2022. Conclusions. There are substantial between-country differences in the current levels and trends of IR in type 1 diabetes in European children and adolescents. Our data suggest a worrying upward trend in most European countries.

15 March 2024 in Nutrition
Verified
Journal Article
Open access
VNVíctor Navas-Moreno
Víctor Navas-Moreno
FSFernando Sebastian-Valles
Fernando Sebastian-Valles
VRVíctor Rodríguez-Laval
Víctor Rodríguez-Laval
CKCarolina Knott-Torcal
Carolina Knott-Torcal
MMMónica Marazuela
Mónica Marazuela
MSMiguel Antonio Sampedro-Núñez
Miguel Antonio Sampedro-Núñez
Treatment with cystic fibrosis transmembrane conductance regulator (CFTR) modulators in individuals with cystic fibrosis (CF) has brought a significant change in forced expiratory volume in 1 second (FEV1) and clinical parameters. However, it also results in weight gain. The aim of our study is to evaluate the effect of CFTR modulator treatment on body composition, measured by computed tomography (CT). Adult subjects with CF under follow-up at La Princesa University Hospital were recruited. All of them were on elexacaftor-tezacaftor-ivacaftor (ELX/TEZ/IVA) treatment. Body composition analysis was conducted using CT scans and an open-source software. The results were then compared with bioimpedance estimations, as well as other clinical and spirometry data. Our sample consisted of 26 adult subjects. The fat mass compartments on CT scans correlated with similar compartments on bioimpedance, and normal-density muscle mass exhibited a strong correlation with phase angle. Higher levels of very low-density muscle prior to treatment were associated with lower final FEV1 and less improvement in FEV1 after therapy. We observed an increase in total body area (P < 0.001), driven by increases in total fat mass (P < 0.001), subcutaneous fat (P < 0.001), visceral fat (P = 0.002), and intermuscular fat (P = 0.022). The only muscle compartment that showed an increase after treatment was very low-density muscle (P = 0.032). CT scans represent an opportunity to assess body composition on CF. Combination treatment with CFTR modulators, leads to an improvement in FEV1 and to an increase in body mass in all compartments primarily at the expense of fat mass.

18 October 2023 in Clinical Nutrition
Verified
Journal Article
Closed access
CTCarolina Knott Torcal
Carolina Knott Torcal
FSFernando Sebastian-Valles
Fernando Sebastian-Valles
RMRosa Mª Giron Moreno
Rosa Mª Giron Moreno
JAJosé Carlos Martín- Adán
José Carlos Martín- Adán
JJJessica Jimenez-Diaz
Jessica Jimenez-Diaz
AAAlfonso Arranz-Martín
Alfonso Arranz-Martín

6 November 2023 in Acta Diabetologica
Verified
Journal Article
Open access
PDF file
FSFernando Sebastian-Valles
Fernando Sebastian-Valles
JMJulia Martínez-Alfonso
Julia Martínez-Alfonso
JMJose Alfonso Arranz Martin
Jose Alfonso Arranz Martin
JJJessica Jiménez-Díaz
Jessica Jiménez-Díaz
IAIñigo Hernando Alday
Iñigo Hernando Alday
MMMónica Marazuela
Mónica Marazuela
Aims: This study aimed to determine the minimum frequency of flash glucose monitoring (FGM) scans necessary for optimal glycemic control in patients with type 1 diabetes (T1D). Methods: Data were collected from 692 patients (47.5% female, with a median age of 47.4 years) who used FGM systems daily and recorded their clinical variables and device data. Results: Logistic regression models showed that performing more than 12 scans per day was associated with improved T1D control (OR = 4.22, p < 0.001) and a reduction in HbA1c (7.6 vs 7.0%, 60–53 mmol/mol p < 0.001). However, those performing less than 6 scans showed no improvement in HbA1c (7.9 vs 7.8%, 63–61 mmol/mol p = 0.514). Thirteen daily scans were determined as the optimal cutoff point for predicting optimal glycemic control using a maximally selected rank algorithm. Significant reductions were observed in mean glucose (< 0.001), coefficient of variation (< 0.001), HbA1c (< 0.001), and an increase in TIR (< 0.001) in patients who performed more than 12 daily scans. Conclusions: The results suggest that a higher frequency of daily scans by T1D patients using FGM systems leads to improved chronic glycemic control. The minimum recommended frequency for optimal control is 13 scans per day, and more than 6 daily scans are needed to improve HbA1c.