Shyh-Jen Wang

Dr. Shyh-Jen Wang


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2007 in Scientometrics
Verified
Journal Article
Closed access
PDF file
Shyh-Jen WangShyh-Jen Wang
Shyh-Jen Wang

Verified
Journal Article
Open access
PDF file
KHKai Hsia
Kai Hsia
CLChih hsun Lin
Chih hsun Lin
HLHsinyu Lee
Hsinyu Lee
WCWei-Min Chen
Wei-Min Chen
Chao-Ling YaoChao-Ling Yao
Chao-Ling Yao
Jenher LuJenher Lu
Jenher Lu
Background: S1P has been shown to improve the endothelialization of decellularized vascular grafts in vitro. Here, we evaluated the potential of tissue-engineered vascular grafts (TEVGs) constructed by ECs and S1P on decellularized vascular scaffolds in a rat model. Methods: Rat aorta was decellularized mainly by 0.1% SDS and characterized by histology. Rat ECs, were seeded onto decellularized scaffolds, and the viability of the ECs was evaluated by biochemical assays. Then, we investigated the in vivo patency rate and endothelialization for five groups of decellularized vascular grafts (each n = 6) in a rat abdominal aorta model for 14 days. The five groups included (1) rat allogenic aorta (RAA); (2) decellularized RAA (DRAA); (3) DRAA with S1P (DRAA/S1P); (4) DRAA with EC recellularization (DRAA/EC); and (5) DRAA with S1P and EC recellularization (DRAA/EC/S1P). Results: In vitro, ECs were identified by the uptake of Dil-Ac-LDL. S1P enhanced the expression of syndecan-1 on ECs and supported the proliferation of ECs on decellularized vascular grafts. In vivo, RAA and DRAA/EC/S1P both had 100% patency without thrombus formation within 14 days. Better endothelialization, more wall structure maintenance and less inflammation were noted in the DRAA/EC/S1P group. In contrast, there was thrombus formation in the DRAA, DRAA/S1P and DRAA/EC groups. Conclusion: S1P could inhibit thrombus formation to improve the patency rate of EC-covered decellularized vascular grafts in vivo and may play an important role in the construction of TEVGs.

1 May 2007 in Applied Ergonomics
Verified
Journal Article
Closed access
BCBao-Chi Chang
Bao-Chi Chang
BHBiing-Shiun Huang
Biing-Shiun Huang
CCChing-Kong Chen
Ching-Kong Chen
Shyh-Jen WangShyh-Jen Wang
Shyh-Jen Wang

1 November 2020 in The American Journal of Medicine
Verified
Journal Article
Closed access
KCKuan-Lin Chen
Kuan-Lin Chen
Shyh-Jen WangShyh-Jen Wang
Shyh-Jen Wang
CCChien Chuang
Chien Chuang
LHLi-Ying Huang
Li-Ying Huang
FCFang-Yao Chiu
Fang-Yao Chiu
WCWei-Ming Chen
Wei-Ming Chen

1 May 2008 in Nature Biotechnology
Verified
Journal Article
Closed access
PDF file
Shyh-Jen WangShyh-Jen Wang
Shyh-Jen Wang

1 March 2011 in Journal of Medical Screening
Verified
Journal Article
Open access
WLWen Huei Liao
Wen Huei Liao
SYShuenn-Tsong Young
Shuenn-Tsong Young
CLChiang-Feng Lien
Chiang-Feng Lien
Shyh-Jen WangShyh-Jen Wang
Shyh-Jen Wang
Objective: The purpose of this study was to develop a cost-effective and easy to use audiometer to monitor progressive hearing change in school-aged children. Design: The hardware of the audiometer developed included a computer, an external sound blaster and a headphone The hearing screening software was developed to control the pure tone sound level with modulability in the range of 0-45 dB HL at 1, 2, 4 and 0.5 kHz frequencies. Thirty sixth-grade children, aged 12-13 years old, were randomly divided into two groups for a hearing test in a conference room. Testing for one group was performed by a person with experience and the other group was examined by a graduate student who was not familiar with the device. After the hearing test, all children were immediately screened using a clinical diagnostic audiometer in a soundproof room by an audiologist. Results: Most of the threshold dB values obtained by the audiometer in a conference room (55 ears, 93.2%) were significantly greater than those obtained by the clinical audiometer in a soundproof room. Most of the differences between these two measurements were within 5 dB (94.9%). Only 5.1% had a discrepancy within the maximum range of 10 dB. The correlation and intraclass correlation coefficients between the two measurements were 0.861 and 0.929, respectively. The results also indicated that the experience level of the screening personnel did not affect the testing. Conclusion: The newly developed audiometer is quite cost-effective and can be easily operated. The threshold dB values obtained by the audiometer developed in a conference room were comparable with the results of a clinical audiometer in a soundproof room. The audiometer developed could measure the hearing threshold values and, therefore, be useful in monitoring progressive hearing change in school-aged children.