Health visitors (HVs) and environmental health officers (EHOs) are the healthcare workers (HCWs) who, in the Italian National Health Service, mainly operate in the prevention departments of local health authorities, guaranteeing the territorial activities specifically declared with the respective professional profiles. During the SARS-CoV-2 pandemic, it was necessary to reallocate all HCWs supporting Hygiene and Public Health Services involved on the front lines of the emergency, in order to perform preventive activities and to take immediate action to fight the spread of the virus. By means of an IT survey consisting of three sections, this study investigated how 960 HVs and EHOs dealt with this reallocation, with the shifting in service assignment, and with the perceived level of fatigue and pressure, through the application of skills acquired from university training. The synergy among the preventive health professions, the ability to work in a multi-professional team, and the complementary training of HCWs represent the main strengths for overcoming future public health challenges, aimed at protecting human health.
Nitrous oxide has a proven clinical efficacy in conscious sedation. At certain environmental concentrations it may pose a health risk to chronically exposed healthcare workers. The present pilot study aims at evaluating the exposure to nitrous oxide of dental ambulatory personnel of a pediatric hospital. A descriptive study design was conducted in two phases: a bibliographic analysis on the environmental safety policies and a gas concentration analysis in the dental ambulatories of a pediatric hospital, detected every 6 months from December 2013 to February 2017 according to law provisions. The surveys were carried out using for gas analysis a photoacoustic spectrometer Innova-B&K “Multi-gas monitor model 1312” and Innova-B&K “Multi-sampler model 1309”. The biological analysis and monitoring have been carried out on staff urine. The analyses were performed during 11 dental outpatient sessions on pediatric patients. All the patients were submitted to the same dental procedures, conservative care and dental extractions. The pediatric patients were 47 (23 males, 24 females; age range 3–17 years; mean age 6,63, SD ± 2,69) for a mean of 4,27 (SD ± 1,49) per session., The mean environmental concentration of nitrous oxide during the sessions was 24.7 ppm (SD ±16,16). A correlation was found between urinary nitrous oxide concentration of dentists (Pearson’s correlation 0.786; p = 0.007) and dental assistants urines (Pearson’s correlation 0.918; p < 0.001) and environmental concentrations of nitrous oxide. Weak negative correlations were found between age and sex of patients and environmental concentrations of nitrous oxide. The mean values of the biological monitoring data referring to all the outpatient sessions are lower than the reference values foreseen in accordance to the regulations in force on nitrous oxide concentration. The mean environmental concentration values recorded in our study are below the limit of 50 ppm considered as a reference point, a value lower than those reported in other similar surveys. The results of the present study provide a contribution to the need to implement technical standards, criteria and system requirements for the dental ambulatories, to date not yet completely defined, and cannot be assimilated to the ones established for the surgical rooms.
The Prevention Technician in the Environment and Workplaces (PTEW) is a health professional who works in the identification, assessment, and management of risk in living and working places. The PTEW implements specific corrective actions at reducing exposure levels to chemicals such as formaldehyde. The aim of this report was to update the formaldehyde risk assessment document (RAD). The risk assessment process was divided into three steps as follows: (1) preliminary data collection, (2) an on-site visit to identify the use patterns and process, and (3) application of the algorithm to calculate the exposure levels of healthcare workers. In addition, with the introduction of closed-circuit systems, 23 devices were evaluated to identify possible airborne dispersion of formaldehyde. The algorithm was applied in 31 hospital units and the results allowed us to classify the staff in two levels of exposure for each hospital unit; healthcare workers were classified as “exposed” or “potentially exposed.” Most of the HCWs are categorized as potentially exposed, and only workers working in laboratories are considered to be exposed. The results showed that devices must be used properly according to the user manual. To increase the level of worker safety, we have proposed to introduce closed-circuit safe handling systems and keeping the duration and intensity of exposure at the lowest possible levels according to the “ALARA” principle. The assignment of the Italian PTEW is to achieve excellence in the levels of health and safety of patients and hospital workers by pursuing a shared mission: improving the quality of public health.
Background: Smartphones in medical settings pose infection risks due to harbouring pathogenic bacteria. Aim: This pilot study assessed the effectiveness duration of sanitization methods, focusing on 70% isopropyl alcohol wipes and ultraviolet-C (UVC) boxes, aiming to obtain preliminary data on the reduction in total bacterial load 3 h post-sanitization. Methods: A randomized monocentric trial with two intervention arms (wipes and UVC boxes) was designed. As participants, healthcare workers from three wards at Fondazione Policlinico Universitario 'A. Gemelli' IRCCS Hospital were recruited, stratified by ward, and block randomized within each ward to control confounders. Findings: Seventy-one healthcare workers, mostly nurses (62%) were included in the study. Initial bacterial load reduction was significant with both disinfection techniques, but after 3 h both methods showed increased bacterial levels, with wipes displaying potentially higher residual efficacy ( P 1 / 4 0.056). To adequately size a trial (89% power, significance level 0.05) for assessing the residual efficacy of alcohol-impregnated wipes compared with UVC boxes at 3 h post-sanitization, 503 professionals per group were required. Conclusion: This study highlights the necessity for guidelines on hospital smartphone sanitization and educational initiatives for healthcare workers and patients. Further studies, adequately sized, are necessary to determine optimal sanitization intervals and assess pathogen transmission risks. 2024 The Author(s). Published by Elsevier Ltd on behalf of The Healthcare Infection Society. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Legionella colonization of water systems represents a potential hazard for humans within healthcare facilities. It is possible to contain its spread through continuous disinfection systems and the correct management and maintenance of the systems. The hygienic and sanitary quality of the water cannot be ignored in an evaluation of the management and energy costs. The Fondazione Policlinico Universitario A. Gemelli IRCCS in Rome has installed the “ME.SI. MR ACS” (MEthod of SavIngs Maximum eneRgy for hot water) device, which allows the system to activate, when necessary, avoiding continuous water recirculation. The objectives of this study are to evaluate the health and hygiene quality of the hospital water network and to evaluate the thermal and electrical energy savings and chlorine dioxide consumption, with and without this device in operation. This study involved three phases of microbiological sampling in the facility under study: ME.SI. MR ACS device installed but not running, with the boilers’ setpoint temperature at 60 °C; device running with the boilers’ setpoint temperature at 60 °C; and device in operation with the boilers’ setpoint temperature at 45 °C. The microbiological analyses were carried out in accordance with the ISO standard. The data show a constant absence of Legionella spp. in all samples. The application of ME.SI. MR ACS on the hot water recirculation circuit leads to a reduction in the daily consumption of electrical and thermal energy of 68.6% and 48.6%, respectively, for a savings of approximately EUR 23,000/year per circuit. Furthermore, with the device in operation, there is a 50% reduction in the chlorine dioxide consumption with a savings of EUR 11,500/year. ME.SI. MR ACS guarantees thermal and electrical energy savings associated with a reduction in chlorine dioxide consumption, maintaining the hygienic and sanitary quality of the water network.
There are 22 different degree courses related to the Healthcare Professions in the Italian university system, which are divided into four areas. “Healthcare Professions of Prevention” is the fourth area and it is fundamental for the National Health Service. In particular, in this pandemic emergency situation, the contribution of the Prevention Technicians in the Environment and Workplaces (PTEW) is essential in the field and workplace management. The “Core Competence” of the PTEW is to carry out, with professional autonomy, prevention, verification, and control activities in the field of hygiene and safety of living and working environments. In the hospitals, the indications provided by national and/or regional authorities are implemented through procedures on good hygiene practices developed by PTEW (e.g., hand hygiene, “respiratory tract hygiene,” environmental hygiene, social distancing, and use of Personal Protective Equipment). One of the activities is the health surveillance on the field by population monitoring. The protocols foreseen for the “in-flow of workers” involve a wider control between social life and work. The PTEW will use a Check List divided into 3 macro phases: Entry, Activity Context, and Exit, defining each behavior of the work phases with a constant presence of verification of the procedures. The PTEW will be a Leader on the topics of education, training, and persuasion, considering a New Principle that “transforms the worker as active part in the application and diffusion of the safety measures”.