S M Shafiul Alam

Dr. S M Shafiul Alam

Energy & Environment Science & Technology, Idaho National Laboratory, Idaho Falls, ID 83415, USA
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2014 in Signal, Image and Video Processing
Verified
Journal Article
Closed access
PDF file
ADAnindya Bijoy Das
Anindya Bijoy Das
MBMohammed Imamul Hassan Bhuiyan
Mohammed Imamul Hassan Bhuiyan
S M Shafiul AlamS M Shafiul Alam
S M Shafiul Alam

9 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
Jianhua ZhangJianhua Zhang
Jianhua Zhang
AHAdarsh Hasandka
Adarsh Hasandka
JWJin Wei-Kocsis
Jin Wei-Kocsis
S M Shafiul AlamS M Shafiul Alam
S M Shafiul Alam
TETarek Elgindy
Tarek Elgindy
BHBri-Mathias Hodge
Bri-Mathias Hodge
Wired and wireless communications both play an important role in the blend of communications technologies necessary to enable future smart grid communications. Hybrid networks exploit independent mediums to extend network coverage and improve performance. However, whereas individual technologies have been applied in simulation networks, as far as we know there is only limited attention that has been paid to the development of a suite of hybrid communication simulation models for the communications system design. Hybrid simulation models are needed to capture the mixed communication technologies and IP address mechanisms in one simulation. To close this gap, we have developed a suite of hybrid communication system simulation models to validate the critical system design criteria for a distributed solar Photovoltaic (PV) communications system, including a single trip latency of 300 ms, throughput of 9.6 Kbps, and packet loss rate of 1%. The results show that three low-power wireless personal area network (LoWPAN)-based hybrid architectures can satisfy three performance metrics that are critical for distributed energy resource communications.

6 December 2022 in Energy Reports
Verified
Journal Article
Open access
MRMohammad Roni
Mohammad Roni
TMThomas Mosier
Thomas Mosier
BLBinghui Li
Binghui Li
S M Shafiul AlamS M Shafiul Alam
S M Shafiul Alam
VDVenkat Durvasulu
Venkat Durvasulu
Vishvas Hiren ChalishazarVishvas Hiren Chalishazar
Vishvas Hiren Chalishazar

12 August 2019 in IET Smart Grid
Verified
Journal Article
Open access
PDF file
TZTodd Zhen
Todd Zhen
TETarek Elgindy
Tarek Elgindy
S M Shafiul AlamS M Shafiul Alam
S M Shafiul Alam
BHBri-Mathias Hodge
Bri-Mathias Hodge
CLCarl D. Laird
Carl D. Laird
Evolving power systems with increasing renewables penetration, along with the development of the smart grid, calls for improved communication networks to support these distributed generation sources. Automatic and optimal placement of communication resources within the advanced metering infrastructure is critical to provide a high‐performing, reliable, and resilient power system. Three network design formulations based on mixed‐integer linear and non‐linear programming approaches are proposed to minimise network congestion by optimising residual buffer capacity through the placement of data concentrators and network routeing. Results on a case study show that the proposed models improve network connectivity and robustness, and increase average residual buffer capacity. Maximising average residual capacity alone, however, results in both oversaturated and underutilised nodes, while maximising either minimum residual capacity or total reciprocal residual capacity can yield much‐improved network load allocation. Consideration of connection redundancy improves network reliability further by ensuring quality‐of‐service in the event of an outage. Analysis of multi‐period network expansion shows that the models do not deviate significantly from optimal when used progressively (within 5% deviation), and are effective for utility planners to use for smart grid expansion.

17 October 2023 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
AMAndrew G. Miles
Andrew G. Miles
YCYacine Chakhchoukh
Yacine Chakhchoukh
S M Shafiul AlamS M Shafiul Alam
S M Shafiul Alam
This paper examines the impact of false data injection (FDI) cyber-attacks on distribution system state estimation (DSSE) and the resulting distribution locational marginal price (DLMP) in power markets. Two robust high-breakdown regression estimators, namely S- and MM- estimators, are implemented to provide resistance against FDI attacks targeting measurements and grid topology, creating leverage points. The introduced estimators are compared to the weighted least squares (WLS) with a bad data detection and rejection module (BDD) and the robust Huber M-estimator. The proposed estimators are shown to be effective and compare favorably to both existing Huber M- and the WLS with BDD in the presence of topology FDI attacks. Both the S- and MM-estimators provide good performance in the case of clean and corrupted measurements. Their performance is comparable in this case to the Huber M- and the WLS, followed by a BDD module. The simulation considered a modified distribution IEEE 13 and 34-bus systems where the impact of FDI attack scenarios is shown on the state and the DLMP pricing in the presence of distributed generation.

20 June 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
YOYemi Ojo
Yemi Ojo
S M Shafiul AlamS M Shafiul Alam
S M Shafiul Alam
WBW. Hill Balliet
W. Hill Balliet
TMThomas M. Mosier
Thomas M. Mosier
This paper proposes a control architecture for frequency, current, and voltage control that facilitates using battery storage to improve the response of standalone small hydropower plants. The frequency controller uses rate-of-change of frequency and frequency-Watt-based generations to produce active power commands. The distinctive feature of the controller design is that it nicely integrates response to frequency change with constraints on frequency and state of battery to enable power injections. The current and voltage control scheme allows incorporating the frequency controller. The distinctive feature of this controller is that it incorporates a bounded integral control strategy that guarantees stability. Results on the stability of the hydropower plant with proposed scheme are presented and robust ways to choose the controller gains are investigated via root locus analysis. Simulations performed show that: the hydropower plant response is significantly improved with battery storage using the proposed scheme; the load carrying capability of the hydropower plant is significantly improved with battery storage; the proposed scheme has the capability to recharge the battery; and the proposed control scheme gives improved performance.