Makiko Nishikawa

Dr. Makiko Nishikawa


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2022 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
TKToshiya Kariyasu
Toshiya Kariyasu
HYHidenori Yamaguchi
Hidenori Yamaguchi
MNMakiko Nishikawa
Makiko Nishikawa
HMHaruhiko Machida
Haruhiko Machida

21 November 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
TKToshiya Kariyasu
Toshiya Kariyasu
HMHaruhiko Machida
Haruhiko Machida
TYTsuneo Yamashiro
Tsuneo Yamashiro
KFKeita Fukushima
Keita Fukushima
MKMasamichi Koyanagi
Masamichi Koyanagi
TSToru Satoh
Toru Satoh
Background: Lung subtraction CT (LSCT), the subtraction of noncontrast CT from CT pulmonary angiography (CTPA) without spatial misregistration, is easily applicable by utilizing a software-based deformable image registration technique without additional hardware and permits the evaluation of lung perfusion as iodine accumulation, similar to that observed in perfusion lung single photon emission CT (PL-SPECT). The aim of this study was to use LSCT to newly assess the quantitative correlation between the CT value on LSCT and radioactive count on PL-SPECT as a reference and validate the quantification of lung perfusion by measuring the CT value in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: We prospectively enrolled 47 consecutive patients with CTEPH undergoing both LSCT and PL-SPECT; we used noncontrast CT, CTPA, and LSCT to measure CT values and PL-SPECT to measure radioactive counts in areas representing three different perfusion classes—no perfusion defect, subsegmental perfusion defect, and segmental perfusion defect; we compared CT values on noncontrast CT, CTPA, and LSCT and radioactive counts on PL-SPECT among the three classes, then assessed the correlation between them. Results: Both the CT values and radioactive counts differed significantly among the three classes (p < 0.01 for all) and showed weak correlation (ρ = 0.38) by noncontrast CT, moderate correlation (ρ = 0.61) by CTPA, and strong correlation (ρ = 0.76) by LSCT. Conclusions: The CT value measurement on LSCT is a novel quantitative approach to assess lung perfusion in CTEPH and only correlates strongly with radioactive count measurement on PL-SPECT.

20 July 2022 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
PDF file
TKToshiya Kariyasu
Toshiya Kariyasu
HYHidenori Yamaguchi
Hidenori Yamaguchi
MNMakiko Nishikawa
Makiko Nishikawa
HMHaruhiko Machida
Haruhiko Machida
A 70-year-old man presenting with acute chest pain was transferred to our hospital. Emergent blood tests showed elevated levels of creatine kinase (CK; 691 IU/L; the reference range, 50–195 IU/L), CK-MB (54 IU/L; the reference range, 0–25 IU/L), and troponin I (35.18 ng/mL; the reference range, 0–0.06 ng/mL); however, no abnormalities were identified on electrocardiogram (ECG; Supplementary image online ) and transthoracic echocardiogram. Under a clinical diagnosis of acute coronary syndrome, emergent catheter coronary angiography (CCA) was performed using a total iodine contrast media (CM) dose of approximately 90 mL, but the culprit lesion could not be identified. Immediately following the CCA, ECG-gated cardiac dual-energy computed tomography (DECT) was performed without CM re-injection or any other special preparation. Iodine density imaging (Panels A and B) revealed late iodine enhancement (LIE) representing acute myocardial infarction (AMI) localized in the interventricular septum more clearly than virtual monochromatic imaging at 70 keV (Panels C and D), which offers similar image contrast to single-energy CT at 120 kVp. The CCA was reviewed to identify a contrast filling defect representing thrombus in the first septal branch (Panel E and see Supplementary data online , Video S1). Due to the small infarct size, the patient was conservatively treated. Three months later, cardiac magnetic resonance (CMR) confirmed late gadolinium enhancement (LGE) in the interventricular septum (Panels F and G), as also shown in the DECT.