Zhao Yujie

Dr. Zhao Yujie


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2024 in Journal of Environmental Sciences
Verified
Journal Article
Closed access
XLXitong Li
Xitong Li
CZChuangchuang Zhang
Chuangchuang Zhang
AWAofan Wang
Aofan Wang
TZTieliang Zhang
Tieliang Zhang
ZHZeying He
Zeying He
QZQiwen Zhou
Qiwen Zhou

1 December 2018 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Closed access
JLJia-Feng Liu
Jia-Feng Liu
ZYZhao Yujie
Zhao Yujie
ZSZhi-Ting Song
Zhi-Ting Song
QZQi-Wen Zhou
Qi-Wen Zhou
XLXiaowei Liu
Xiaowei Liu
HFHong-Tao Fan
Hong-Tao Fan

16 January 2020 in Polish Journal of Environmental Studies
Verified
Journal Article
Closed access
RSRongguang Shi
Rongguang Shi
LYLi Yuan
Li Yuan
MCMing-Li Chen
Ming-Li Chen
XZXiangqun Zheng
Xiangqun Zheng
XLXiaowei Liu
Xiaowei Liu
ZZZongshan Zhao
Zongshan Zhao
In this study, 10 frequently used pesticides in apple orchards from the major apple production area of China were identified through 150 questionnaires. Based on Orbitrap high-resolution mass spectrometry, a method for detecting these pesticides in soils was developed. Typically, these compounds can be extracted from dry soil samples using dichloromethane: acetone (2:1, v:v) and purified by dispersive solid-phase extraction (PSA and C18). The qualitative and quantitative analyses can be undertaken by monitoring the MS1 precursor ions under full scan mode within a mass error of <5 ppm (resolution 120000). The recoveries ranged from 68.4% to 102.4% (SD<10.5%), the matrix effects induced signal fluctuation was less than 10%, and the intra- and inter-day precisions were all below 5%. For 14 surface soil samples randomly collected from an apple orchard in China, most pesticides presented the highest detection frequencies (100%), with imidacloprid and tebuconazole showing the highest residue levels (4.1-39.1 and 9.8-350.2 ng/g dry weight, respectively). Compared with previous methods for analyzing individual or several pesticides, the proposed method represents a promising means of investigating these frequently used pesticide residues in apple orchards in China.

26 June 2018 in Environmental Chemistry
Verified
Journal Article
Closed access
PDF file
HYHui Yao
Hui Yao
NYNan You
Nan You
HCHong-Guang Cao
Hong-Guang Cao
LKLi-Xia Kang
Li-Xia Kang
JWJin-Bao Wu
Jin-Bao Wu
YYYanli Yi
Yanli Yi
Environmental context: Low availability of calcium (Ca2+) in soils is one of the major factors in Ca2+ deficiency of plants and physiological plant disorders. A device based on functionalised silica was developed for in-situ measurement of the available Ca2+ in soils. Application of the proposed device to measure available Ca2+ may help to develop and improve agricultural practices. Calcium is an ion of particular interest due to its importance in plant nutrition and soil structure. A novel device of diffusion gradients in thin-films (DGT) based on the benzo-crown ether-functionalised silica (BCES) as the binding agent and the polyethersulfone (PES) membrane as diffusive layer (BCES-DGT) was developed for in-situ sampling of available calcium (Ca2+) in freshwater and soil samples. The performance characteristics of the BCES-DGT device were assessed. The BCES was prepared using the sol-gel process and characterised by Fourier transform infrared spectroscopy, scanning electron microscopy, thermal gravimetric analysis and N2 adsorption–desorption. Results evinced that BCES was obtained successfully with a rough wrinkled surface and good specific surface area of 111.3 m2 g-1. The diffusion coefficient of Ca2+ ions in PES membrane was found to be 1.23 × 10-6 cm2 s-1 at 25 °C and was independent of pH in the range of 3–10 and ionic strength (as pNaCl) from 1 to 3. The high binding capacity of BCES binding gel for Ca2+ ions was determined to be 9822.4 ± 452.9 µg Ca2+/disk and was conducive to the deployment of long-term or high concentration. The BCES-DGT device can accurately measure the concentrations of Ca2+ over wide ranges of ionic strengths (1–3 as pNaCl) and pH (5–10). There was no significant interference on the uptake of Ca2+ by the BCES-DGT device at the tolerance limits up to 500 for Mg2+, Li+, HCO3-, H2PO4-, NO3- and SO42-, 250 for Sr2+, 2000 for K+ and 50 for fulvic acid. The results from BCES-DGT device were in excellent agreement with those measured directly using ion selective electrode in several water and soil samples. Field application in river water indicated that a good agreement was obtained between BCES-DGT value and mean grab sample measurements of Ca2+ and that the relative standard deviation of BCES-DGT measurement (4.7 %) was superior to that of grab sample measurements (13.5 %), suggesting that BCES-DGT was reliable for in-situ sampling and measurement of available Ca2+ with good accuracy and precision.

1 January 2020 in Desalination and Water Treatment
Verified
Journal Article
Closed access
ZYZhao Yujie
Zhao Yujie
MXMin Xiao
Min Xiao
SZShan Zhao
Shan Zhao
HFHongtao Fan
Hongtao Fan

1 August 2006
Verified
Journal Article
Closed access
ZYZhao Yujie
Zhao Yujie
RSRong-Guang Shi
Rong-Guang Shi
ZBZhi-Peng Bai
Zhi-Peng Bai
XFXue-Qi Fu
Xue-Qi Fu
FLFeng-Zhi Liu
Feng-Zhi Liu
HGHuai-You Gao
Huai-You Gao