Ke Si

Prof. Ke Si

State Key Laboratory of Modern Optical Instrumentation, Department of Optical Engineering, Zhejiang University, Hangzhou 310027, China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2012 in Nature Photonics
Verified
Journal Article
Open access
PDF file
KSKe Si
Ke Si
RFReto Fiolka
Reto Fiolka
MCMeng Cui
Meng Cui
Fluorescence imaging has revolutionized biomedical research over the past three decades. Its high molecular specificity and unrivalled single-molecule-level sensitivity have enabled breakthroughs in a number of research fields. For in vivo applications its major limitation is its superficial imaging depth, a result of random scattering in biological tissues causing exponential attenuation of the ballistic component of a light wave. Here, we present fluorescence imaging beyond the ballistic regime by combining single-cycle pulsed ultrasound modulation and digital optical phase conjugation. We demonstrate a near-isotropic three-dimensional localized sound–light interaction zone. With the exceptionally high optical gain provided by the digital optical phase conjugation system, we can deliver sufficient optical power to a focus inside highly scattering media for not only fluorescence imaging but also a variety of linear and nonlinear spectroscopy measurements. This technology paves the way for many important applications in both fundamental biology research and clinical studies.

17 May 2019 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
XZXinpei Zhu
Xinpei Zhu
LHLimeng Huang
Limeng Huang
YZYao Zheng
Yao Zheng
YSYanchun Song
Yanchun Song
QXQiaoqi Xu
Qiaoqi Xu
WGWei Gong
Wei Gong
Significance: Most biological tissue is opaque, and the inside fine structures are invisible even with a microscope. Optical clearing methods can reduce the scattering and enable us to “look” inside the biological samples. Current optical clearing methods suffer from large time consumption, tissue distortion, and fluorescence quenching, which greatly limit their applications. Here, we describe a nontoxic ultrafast optical clearing method (FOCM), which could clarify 300-µm-thick brain slices within 2 min without morphology distortion. The fluorescence can be preserved up to 86% even after 11 d. Besides, the cheap reagents and easy operation makes our method have great potential to be widely used. Besides the brain slices, our method can also be applied to other biological tissues.

1 November 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
LHLejia Hu
Lejia Hu
SHShuwen Hu
Shuwen Hu
WGWei Gong
Wei Gong
KSKe Si
Ke Si
We present a learning-based Shack-Hartmann wavefront sensor (SHWS) to achieve the high-order aberration detection without image segmentation or centroid positioning. Zernike coefficient amplitudes of aberrations measured from biological samples are referred and expanded to generate the training datasets. With one SHWS pattern inputted, up to 120th Zernike modes could be predicted within 10.9 ms with 95.56% model accuracy by a personal computer. The statistical experimental results show that compared with traditional modal-based SHWS, the root mean squared error in phase residuals of this method is reduced by ∼40.54% and the Strehl ratio of the point spread functions is improved by ∼27.31%. The aberration detection performance of this method is also validated on a mouse brain slice with 300 µm thickness and the median improvement of peak-to-background ratio of this method is ∼30% to 40% compared with traditional SHWS. With the high detection accuracy, simple processes, fast prediction speed and good compatibility, this work offers a potential approach to improve the wavefront sensing ability of SHWS, which could be combined with an existing adaptive optics system and be further applied in biological applications.

30 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YYYang Yu
Yang Yu
JWJiahao Wang
Jiahao Wang
CNChan Way Ng
Chan Way Ng
YMYukun Ma
Yukun Ma
SMShupei Mo
Shupei Mo
HYHanry Yu
Hanry Yu
Current liver fibrosis scoring by computer-assisted image analytics is not fully automated as it requires manual preprocessing (segmentation and feature extraction) typically based on domain knowledge in liver pathology. Deep learning-based algorithms can potentially classify these images without the need for preprocessing through learning from a large dataset of images. We investigated the performance of classification models built using a deep learning-based algorithm pre-trained using multiple sources of images to score liver fibrosis and compared them against conventional non-deep learning-based algorithms - artificial neural networks (ANN), multinomial logistic regression (MLR), support vector machines (SVM) and random forests (RF). Automated feature classification and fibrosis scoring were achieved by using a transfer learning-based deep learning network, AlexNet-Convolutional Neural Networks (CNN), with balanced area under receiver operating characteristic (AUROC) values of up to 0.85–0.95 versus ANN (AUROC of up to 0.87–1.00), MLR (AUROC of up to 0.73–1.00), SVM (AUROC of up to 0.69–0.99) and RF (AUROC of up to 0.94–0.99). Results indicate that a deep learning-based algorithm with transfer learning enables the construction of a fully automated and accurate prediction model for scoring liver fibrosis stages that is comparable to other conventional non-deep learning-based algorithms that are not fully automated.

30 June 2020 in Optics Letters
Verified
Journal Article
Closed access
LHLejia Hu
Lejia Hu
SHShuwen Hu
Shuwen Hu
WGWei Gong
Wei Gong
KSKe Si
Ke Si
The conventional Shack–Hartmann wavefront sensor (SHWS) requires wavefront slope measurements of every micro-lens for wavefront reconstruction. In this Letter, we applied deep learning on the SHWS to directly predict the wavefront distributions without wavefront slope measurements. The results show that our method could provide a lower root mean square wavefront error in high detection speed. The performance of the proposed method is also evaluated on challenging wavefronts, while the conventional approaches perform insufficiently. This Letter provides a new approach, to the best of our knowledge, to perform direct wavefront detection in SHWS-based applications.

19 October 2012 in Scientific Reports
Verified
Journal Article
Open access
KSKe Si
Ke Si
RFReto Fiolka
Reto Fiolka
MCMeng Cui
Meng Cui
Optical microscopy has so far been restricted to superficial layers, leaving many important biological questions unanswered. Random scattering causes the ballistic focus, which is conventionally used for image formation, to decay exponentially with depth. Optical imaging beyond the ballistic regime has been demonstrated by hybrid techniques that combine light with the deeper penetration capability of sound waves. Deep inside highly scattering media, the sound focus dimensions restrict the imaging resolutions. Here we show that by iteratively focusing light into an ultrasound focus via phase conjugation, we can fundamentally overcome this resolution barrier in deep tissues and at the same time increase the focus to background ratio. We demonstrate fluorescence microscopy beyond the ballistic regime of light with a threefold improved resolution and a fivefold increase in contrast. This development opens up practical high resolution fluorescence imaging in deep tissues.