Siqi Lin

Prof. Siqi Lin

Faculty of Architecture, Civil and Transportation Engineering, Beijing University of Technology, Beijing 100124, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Thin-Walled Structures
Verified
Journal Article
Closed access
Xi-Feng YanXi-Feng Yan
Xi-Feng Yan
YZYan-Gang Zhao
Yan-Gang Zhao
Siqi LinSiqi Lin
Siqi Lin

1 January 2018 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
LHLiusheng He
Liusheng He
YZYangang Zhao
Yangang Zhao
Siqi LinSiqi Lin
Siqi Lin

1 October 2018 in Engineering Structures
Verified
Journal Article
Closed access
Siqi LinSiqi Lin
Siqi Lin
YZYan-Gang Zhao
Yan-Gang Zhao
LHLiusheng He
Liusheng He

1 February 2018 in Engineering Structures
Verified
Journal Article
Closed access
YZYan-Gang Zhao
Yan-Gang Zhao
Siqi LinSiqi Lin
Siqi Lin
ZLZhao-Hui Lu
Zhao-Hui Lu
TSTakasuke Saito
Takasuke Saito
LHLiusheng He
Liusheng He

1 September 2019 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
Siqi LinSiqi Lin
Siqi Lin
YZYan-Gang Zhao
Yan-Gang Zhao

18 April 2019 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
LHLiusheng He
Liusheng He
Siqi LinSiqi Lin
Siqi Lin
HJHuanjun Jiang
Huanjun Jiang
Concrete-filled steel tube (CFST) columns are increasingly used in composite construction. Under axial compression, the steel tube will sustain partial axial force and meanwhile provides the confinement to the infill concrete. The high axial strength capacity of CFST columns is largely related to the confinement provided by the steel tube. Extensive studies on CFST columns have been conducted. Nevertheless, how to quantify the efficiency of confinement effect in CFST columns using concrete with different strength grades is still missing. To address this issue, a series of compressive loading tests on CFST columns were conducted in present study. The variable parameters studied include concrete strength and diameter-to-thickness ratio of the steel tube. Six CFST stub columns in total were designed and tested under uniaxial compression. Axial strength, stress state in the steel tube, confined concrete strength and confining pressure acting on the infill concrete were carefully investigated. Test results show that the confinement factor (defined as the ratio of the nominal strength of empty steel tube to that of the unconfined concrete) is the most dominant factor influencing the confinement effect, and a larger confinement factor gives higher confinement effect. The low-strength concrete exhibits better performance of ductility and confinement compared with the high-strength concrete. The index of equivalent confining pressure was used to quantify the level of passive confinement provided by the steel tube in CFST columns. Based on the test results, a method to quickly quantify the confining pressure provided by the steel tube was proposed.