Toshiyuki Tateiwa

Dr. Toshiyuki Tateiwa

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Journal of Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
TTToshiyuki Tateiwa
Toshiyuki Tateiwa
TITsunehito Ishida
Tsunehito Ishida
TMToshinori Masaoka
Toshinori Masaoka
TSTakaaki Shishido
Takaaki Shishido
YTYasuhito Takahashi
Yasuhito Takahashi
KYKengo Yamamoto
Kengo Yamamoto
The purpose of the present study was to follow up Japanese patients with deep vein thrombosis (DVT) after total knee arthroplasty (TKA) and also to examine factors associated with residual thrombus within the sixth postoperative month. DVT evaluation was performed by noninvasive venous ultrasonography. We retrospectively reviewed 88 Japanese patients (88 knees) receiving primary unilateral TKA, who had no preoperative DVT. We examined the influence of the following four factors on postoperative DVT: (1) patient factors (age, sex, body height, body weight, and body mass index), (2) surgical factors (operation time, bleeding amount, avascularization time, and anesthesia method), (3) postoperative factors (bleeding amount, period to ambulation, period of venous foot pump use, and ratio of graduated compression stocking use), and (4) DVT conditional factors (location, length, number of vein branches, and the presence of >5 mm vasodilatation). The total prevalence of venous thromboembolism (VTE) was 62.5% (55 of the 88 patients). Among the 55 VTE patients, the rates of distal and proximal DVT were 96.4% and 3.6%, respectively. Bilateral DVT was found in 34.5%, while unilateral DVT on the surgical and nonsurgical sides were 52.7% and 12.7%, respectively. Asymptomatic pulmonary embolism was 1.8%. DVT was exacerbated in five patients (11.9%), of whom three showed additional thrombus formation. The remaining two patients had thrombus elongation or propagation from distal to proximal veins. In comparisons between thrombus-unresolved and -resolved groups within the sixth postoperative month, statistical significances were found in the incidence of bilateral DVT (50.0% vs. 15.4%, p = 0.02) and unilateral DVT (43.8% vs. 76.9%, p = 0.02). On the other hand, operation time (107.0 ± 17.3 min vs. 94.5 ± 11.9 min, p = 0.01) and avascularization time (99.8 ± 17.6 min vs. 88.0 ± 11.5 min, p = 0.01) in bilateral DVT patients were significantly longer than in unilateral ones. Our results suggest that an extended operation and avascularization time may be a risk factor for bilateral DVT and residual thrombus over 6 months.

29 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
MYMakiko Yorifuji
Makiko Yorifuji
Saverio AffatatoSaverio Affatato
Saverio Affatato
TTToshiyuki Tateiwa
Toshiyuki Tateiwa
YTYasuhito Takahashi
Yasuhito Takahashi
TSTakaaki Shishido
Takaaki Shishido
KYKengo Yamamoto
Kengo Yamamoto
The purpose of the present study was to compare the wear behavior of ceramic-on-vitamin-E-diffused crosslinked polyethylene (Vit-E XLPE) hip bearings employing the gold standard oxide ceramic, zirconia (ZrO2)-toughened alumina (Al2O3) (ZTA, BIOLOX®delta) and a new non-oxide ceramic, silicon nitride (Si3N4, MC2®). In vitro wear test was performed using a 12-station hip joint simulator. The test was carried out by applying the kinematic inputs and outputs as recommended by ISO 14242-1:2012. Vitamin-E-diffused crosslinked polyethylene (Vit-E XLPE) acetabular liners (E1®) were coupled with Ø28-mm ZTA and Si3N4 femoral heads. XLPE liner weight loss over 5 million cycles (Mc) of testing was compared between the two different bearing couples. Surface topography, phase contents, and residual stresses were analyzed by contact profilometer and Raman microspectroscopy. Vit-E XLPE liners coupled with Si3N4 heads produced slightly lower wear rates than identical liners with ZTA heads. The mean wear rates (corrected for fluid absorption) of liners coupled with ZTA and Si3N4 heads were 0.53 ± 0.24 and 0.49 ± 0.23 mg/Mc after 5 Mc of simulated gait, respectively. However, after wear testing, the ZTA heads retained a smoother topography and showed fewer surface stresses than the Si3N4 ones. Note that no statistically significant differences were found in the above comparisons. This study suggests that the tribochemically formed soft silica layer on the Si3N4 heads may have reduced friction and slightly lowered the wear of the Vit-E XLPE liners. Considering also that the toughness of Si3N4 is superior to ZTA, the present wear data represent positive news in the future development of long-lasting hip components.

12 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
TTToshiyuki Tateiwa
Toshiyuki Tateiwa
Elia MarinElia Marin
Elia Marin
ARAlfredo Rondinella
Alfredo Rondinella
MCMarco Ciniglio
Marco Ciniglio
WZwenliang zhu
wenliang zhu
KYKengo Yamamoto
Kengo Yamamoto
Zirconia-toughened alumina (ZTA) currently represents the bioceramic gold standard for load-bearing components in artificial hip joints. ZTA is long known for its high flexural strength and fracture toughness, both properties arising from a microscopic crack-tip shielding mechanism due to the stress-induced tetragonal-to-monoclinic (t→m) polymorphic transformation of zirconia. However, there have been concerns over the years regarding the long-term structural performance of ZTA since the t→m transformation also spontaneously occurs at the material’s surface under low-temperature environmental conditions with a concomitant degradation of mechanical properties. Spontaneous surface degradation has been extensively studied in vitro, but predictive algorithms have underestimated the extent of in vivo degradation observed in retrievals. The present research focused on burst-strength assessments of Ø28 mm ZTA femoral before and after long-term in vitro hydrothermal ageing according to ISO 7206-10. An average burst strength of 52 kN was measured for pristine femoral heads. This value was ~36% lower than results obtained under the same standard conditions by other authors. A further loss of burst strength (~13% in ultimate load) was observed after hydrothermal ageing, with increased surface monoclinic content ranging from ~6% to >50%. Nevertheless, the repetitively stressed and hydrothermally treated ZTA heads exceeded the minimum burst strength stipulated by the US Food and Drug Administration (FDA) despite severe test conditions. Lastly, Raman spectroscopic assessments of phase transformation and residual stresses on the fracture surface of the femoral heads were used to clarify burst-strength fluctuations and the effect of hydrothermal ageing on the material’s overall strength degradation.

24 April 2020 in Journal of Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
TTToshiyuki Tateiwa
Toshiyuki Tateiwa
KEKenji Endo
Kenji Endo
YMYuji Matsuoka
Yuji Matsuoka
TITsunehito Ishida
Tsunehito Ishida
TSTakaaki Shishido
Takaaki Shishido
KYKengo Yamamoto
Kengo Yamamoto
It is important to understand postoperative global sagittal spinal alignment after total hip arthroplasty (THA) to prevent not only the following hip complications but also progressing lumbar degeneration. The purpose of this study was to progress the analysis of the global sagittal spinal alignment between before and after THA in patients without large lower limbs discrepancy. The subjects were 87 patients with bilateral hip osteoarthritis (OA) before unilateral primary THA. We measured sagittal vertical axis (SVA), lumbar lordotic angle, sacral slope, pelvic tilt (PT), and pelvic incidence (PI) and compared the postoperative change of those parameters. Excluded criteria were Crowe classification types II, III, and IV and more than 10 mm of leg length difference, spinal scoliosis (Cobb angle > 25°), and lumbar kyphosis. The correlation coefficient between preoperative factors and postoperative sagittal alignments revealed that postoperative SVA has correlation with age (r = 0.46, p < 0.008) and preoperative PT (r = 0.42, p = 0.015). Postoperative PT had a correlation with preoperative PI (r = 0.46, p = 0.007). The change of PT after operation had negative correlation to preoperative PT (r = −0.47, p < 0.01) and PI (r = −0.38, p = 0.03). Multiple regression analysis revealed that the change of PT = 4.979 − 0.235 × preoperative PT (p < 0.05). Therefore, when preoperative PT was less than 20°, the postoperative PT would become larger than the preoperative one. (1) In patient with hip OA without large lower limbs discrepancy, the postoperative PT after THA correlated with PI. (2) The postoperative change of PT was influenced by preoperative PT.

1 September 2015 in Therapeutics and Clinical Risk Management
Verified
Journal Article
Open access
PDF file
TTToshiyuki Tateiwa
Toshiyuki Tateiwa
YTYasuhito Takahashi
Yasuhito Takahashi
TITsunehito Ishida
Tsunehito Ishida
KKKosuke Kubo
Kosuke Kubo
TMToshinori Masaoka
Toshinori Masaoka
KYKengo Yamamoto
Kengo Yamamoto
It has been recognized that perioperative hemostasis management after joint-replacement surgery for hemophilia patients is complicated and cumbersome, due to the necessity of rigorous monitoring for clotting-factor levels throughout the infusion. Between 2005 and 2014, we examined seven patients with hemophilia A (ten joints: six hips and four knees) receiving total hip or knee arthroplasty (THA or TKA) for hemophilic arthropathy. One male patient (31 years old) showed an intra-articular hematoma formation after THA (case 1). In another male patient (46 years old) receiving TKA, the postoperative trough factor VIII level became lower significantly than reference levels (80%–100% for the 5–10 postoperative days) recommended by the guidelines from the Japanese Society on Thrombosis and Hemostasis, despite sufficient coagulant based on the guidelines being administered (case 2). In the latter patient, deep infection and hematoma formation were observed postoperatively. In this article, we provide a detailed clinical report regarding these two complication cases at the early postoperative periods, and the management of bleeding control for hemophilia patients is discussed.

1 October 2021 in Arthroplasty Today
Verified
Journal Article
Open access
TITsunehito Ishida
Tsunehito Ishida
TTToshiyuki Tateiwa
Toshiyuki Tateiwa
YTYasuhito Takahashi
Yasuhito Takahashi
RTReisuke H. Takahashi
Reisuke H. Takahashi
KSKeiji Sano
Keiji Sano
KYKengo Yamamoto
Kengo Yamamoto
We present a rare case of symptomatic adverse local tissue reaction in a 54-year-old female patient who had undergone total hip arthroplasty with ceramic-on-ceramic bearing. Inflammatory periarticular mass and osteolysis developed in the absence of cobalt chrome alloy interfaces and a modular neck component. On the pathologic images, there was no clear evidence of gross metal staining of tissues, metal corrosion, and ceramic or metal wear particles. However, there were impingement scars on the titanium alloy femoral neck and acetabular cup associated with a high combined anteversion angle of 75° (stem: 40° and cup: 35°), suggesting titanium debris release in vivo. Immunohistochemical staining proved a predominant infiltration of CD4+ T cells and the corresponding IL-17A response to metal. We conclude that neck-rim impingement may lead to the development of adverse local tissue reaction (periarticular mass and osteolysis) due to a metal hypersensitivity with the production of proinflammatory cytokines (IL-17A) by CD4+ T cells even in ceramic-on-ceramic total hip arthroplasty.