Mohsin Ali Raza

Dr. Mohsin Ali Raza


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Muhammad Umar Aslam KhanMuhammad Umar Aslam Khan
Muhammad Umar Aslam Khan
IIIqra Iqbal
Iqra Iqbal
MAM.N.M. Ansari
M.N.M. Ansari
Saiful Izwan Abd RazakSaiful Izwan Abd Razak
Saiful Izwan Abd Razak
MRMohsin Ali Raza
Mohsin Ali Raza
Norhana JusohNorhana Jusoh
Norhana Jusoh
The present research is based on the fabrication preparation of CS/PVA/GG blended hydrogel with nontoxic tetra orthosilicate (TEOS) for sustained paracetamol release. Different TEOS percentages were used because of their nontoxic behavior to study newly designed hydrogels’ crosslinking and physicochemical properties. These hydrogels were characterized using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and wetting to determine the functional, surface morphology, hydrophilic, or hydrophobic properties. The swelling analysis in different media, degradation in PBS, and drug release kinetics were conducted to observe their response against corresponding media. The FTIR analysis confirmed the components added and crosslinking between them, and surface morphology confirmed different surface and wetting behavior due to different crosslinking. In various solvents, including water, buffer, and electrolyte solutions, the swelling behaviour of hydrogel was investigated and observed that TEOS amount caused less hydrogel swelling. In acidic pH, hydrogels swell the most, while they swell the least at pH 7 or higher. These hydrogels are pH-sensitive and appropriate for controlled drug release. These hydrogels demonstrated that, as the ionic concentration was increased, swelling decreased due to decreased osmotic pressure in various electrolyte solutions. The antimicrobial analysis revealed that these hydrogels are highly antibacterial against Gram-positive (Staphylococcus aureus and Bacillus cereus) and Gram negative (Pseudomonas aeruginosa and Escherichia coli) bacterial strains. The drug release mechanism was 98% in phosphate buffer saline (PBS) media at pH 7.4 in 140 min. To analyze drug release behaviour, the drug release kinetics was assessed against different mathematical models (such as zero and first order, Higuchi, Baker–Lonsdale, Hixson, and Peppas). It was found that hydrogel (CPG2) follows the Peppas model with the highest value of regression (R2 = 0.98509). Hence, from the results, these hydrogels could be a potential biomaterial for wound dressing in biomedical applications.

16 September 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Muhammad Umar Aslam KhanMuhammad Umar Aslam Khan
Muhammad Umar Aslam Khan
ZBZahida Begum
Zahida Begum
MAM.N.M. Ansari
M.N.M. Ansari
Saiful Izwan Abd RazakSaiful Izwan Abd Razak
Saiful Izwan Abd Razak
MRMohsin Ali Raza
Mohsin Ali Raza
Mh Busra FauziMh Busra Fauzi
Mh Busra Fauzi
The composite hydrogels were produced using the solution casting method due to the non-toxic and biocompatible nature of chitosan (CS)/polyvinyl alcohol (PVA). The best composition was chosen and crosslinked with tetraethyl orthosilicate (TEOS), after which different amounts of graphene oxide (GO) were added to develop composite hydrogels. Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), atomic force microscopy (AFM) and contact angle was used to analyze the hydrogels. The samples were also evaluated for swelling abilities in various mediums. The drug release profile was studied in phosphate-buffered saline (PBS) at a pH of 7.4. To predict the mechanism of drug release, the data were fitted into kinetic models. Finally, antibacterial activity and cell viability data were obtained. FTIR studies revealed the successful synthesis of CS/PVA hydrogels and GO/CS/PVA in hydrogel composite. SEM showed no phase separation of the polymers, whereas AFM showed a decrease in surface roughness with an increase in GO content. 100 µL of crosslinker was the critical concentration at which the sample displayed excellent swelling and preserved its structure. Both the crosslinked and composite hydrogel showed good swelling. The most acceptable mechanism of drug release is diffusion-controlled, and it obeys Fick’s law of diffusion for drug released. The best fitting of the zero-order, Hixson-Crowell and Higuchi models supported our assumption. The GO/CS/PVA hydrogel composite showed better antibacterial and cell viability behaviors. They can be better biomaterials in biomedical applications.

6 August 2020 in Journal of Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Closed access
PDF file
MKMuhammad Umar Aslam Khan
Muhammad Umar Aslam Khan
MRMohsin Ali Raza
Mohsin Ali Raza
Saiful Izwan Abd RazakSaiful Izwan Abd Razak
Saiful Izwan Abd Razak
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
AHAdnan Haider
Adnan Haider
SASaira Aftab
Saira Aftab

1 December 2017 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
FGFaizan Ali Ghauri
Faizan Ali Ghauri
MRMohsin Ali Raza
Mohsin Ali Raza
MBMuhammad Saad Baig
Muhammad Saad Baig
SIShoaib Ibrahim
Shoaib Ibrahim

17 May 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Muhammad Umar Aslam KhanMuhammad Umar Aslam Khan
Muhammad Umar Aslam Khan
WAWafa Shamsan Al Arjan
Wafa Shamsan Al Arjan
MBMona Saad Binkadem
Mona Saad Binkadem
Hassan MehboobHassan Mehboob
Hassan Mehboob
AAadnan Afridi
adnan Afridi
RARashid Amin
Rashid Amin
Bone tissue engineering is an advanced field for treatment of fractured bones to restore/regulate biological functions. Biopolymeric/bioceramic-based hybrid nanocomposite scaffolds are potential biomaterials for bone tissue because of biodegradable and biocompatible characteristics. We report synthesis of nanocomposite based on acrylic acid (AAc)/guar gum (GG), nano-hydroxyapatite (HAp NPs), titanium nanoparticles (TiO2 NPs), and optimum graphene oxide (GO) amount via free radical polymerization method. Porous scaffolds were fabricated through freeze-drying technique and coated with silver sulphadiazine. Different techniques were used to investigate functional group, crystal structural properties, morphology/elemental properties, porosity, and mechanical properties of fabricated scaffolds. Results show that increasing amount of TiO2 in combination with optimized GO has improved physicochemical and microstructural properties, mechanical properties (compressive strength (2.96 to 13.31 MPa) and Young’s modulus (39.56 to 300.81 MPa)), and porous properties (pore size (256.11 to 107.42 μm) and porosity (79.97 to 44.32%)). After 150 min, silver sulfadiazine release was found to be ~94.1%. In vitro assay of scaffolds also exhibited promising results against mouse pre-osteoblast (MC3T3-E1) cell lines. Hence, these fabricated scaffolds would be potential biomaterials for bone tissue engineering in biomedical engineering.

25 October 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Muhammad Faheem MaqsoodMuhammad Faheem Maqsood
Muhammad Faheem Maqsood
MRMohsin Ali Raza
Mohsin Ali Raza
ZRZaeem Ur Rehman
Zaeem Ur Rehman
ATAsima Tayyeb
Asima Tayyeb
Muhammad Atif MakhdoomMuhammad Atif Makhdoom
Muhammad Atif Makhdoom
Muhammad Farooq KhanMuhammad Farooq Khan
Muhammad Farooq Khan
Clinical applications of bio-absorbable magnesium (Mg) and its alloys can be enhanced by increasing their corrosion resistance, using surface modification and functionality. In this study, we synthesized graphene oxide (GO) through improved Hummers’ method and deposited it on biodegradable AZ31B Mg alloy for further characterization. Different suspensions of GO were prepared in various solvents, like deionized water, ethanol, and acetone by ultra-sonication. Electrophoretic deposition (EPD) was used to develop GO coatings on AZ31B Mg using different GO suspensions. Effect of various solvents on corrosion behavior, as well as in vitro biocompatibility, was studied. The optimized EPD parameters were 3 volts and 90 s for coating. Different characterization techniques were used to study GO and prepared coatings. Atomic force microscopy found that the average thickness of GO was ~1 nm. Electrochemical behavior of coatings was studied through electrochemical impedance spectroscopy (EIS) and Tafel analysis in Ringer’s lactate solution. Tafel analysis revealed that GO coatings deposited by GO water suspension increased corrosion protection efficiency of AZ31B Mg alloy by ~94%. After 72 h incubation in MC3T3-E1 osteoblast cells extract, in vitro analysis was performed to determine the cell viability and biocompatibility of the GO- coated and bare Mg samples. GO coatings deposited by GO water suspension demonstrated ~2× cell viability, as well as nontoxicity and better biocompatibility compared to the bare and other GO-coated Mg samples.