Distance relay design is equipped with out-of-step tripping scheme to ensure correct distance relay operation during power swing. The out-of-step condition is a consequence result from unstable power swing. It requires proper detection of power swing to initiate a tripping signal followed by separation of unstable part from the entire power system. The distinguishing process of unstable swing from stable swing poses a challenging task. This paper presents an intelligent approach to detect power swing based on S-Transform signal processing tool. The proposed scheme is based on the use of S-Transform feature of active power at the distance relay measurement point. It is demonstrated that the proposed scheme is able to detect and discriminate the unstable swing from stable swing occurring in the system. To ascertain validity of the proposed scheme, simulations were carried out with the IEEE 39 bus system and its performance has been compared with the wavelet transform–based power swing detection scheme.
This paper presents Evolutionary Programming (EP) based optimisation technique for estimating synchronising torque coefficients, K s and damping torque coefficients, K d of a synchronous machine. These coefficients are used to identify the angle stability of a system. Initially, a Simulink model was utilised to generate the time domain response of rotor angle under various loading conditions. EP was then implemented to optimise the values of K s and K d within the same loading conditions. Result obtained from the experiment are very promising and revealed that it outperformed the Least Square (LS) and Artificial Immune System (AIS) methods during the comparative studies. Validation with respect to eigenvalues determination confirmed that the proposed technique is feasible to solve the angle stability problems.
As the load demand in a power system increases, power system operators struggle to maintain the power system to be operated within its acceptable limits. If no mitigation actions are taken, a power system may suffer from voltage collapse, which in turn leads to blackout. Flexible AC Transmission System (FACTS) devices can be employed to help improve the voltage profile of the power system. This paper presents the implementation of Chaotic Immune Symbiotic Organism Search (CISOS) optimization technique to solve optimal Thyristor Controlled Series Compensator (TCSC) in a power system for voltage profile improvement. Validation process are conducted on IEEE 26-bus RTS resulting in the capability of CISOS in solving the allocation problem with a better voltage profile. Comparative studies conducted with respect to Particle Swarm Optimization (PSO) and Evolutionary Programming (EP) has revealed the superiority of CISOS over PSO and EP in solving the optimal allocation problem by producing optimal solution with a better voltage profile. The results and information obtained from this study can help power system operator in terms of optimal compensation in power system as well as improving the operation of a power system.