TAREK KAMMOUN

Dr. TAREK KAMMOUN


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
julien frandonjulien frandon
julien frandon
PAPhilippe Akessoul
Philippe Akessoul
TKTAREK KAMMOUN
TAREK KAMMOUN
Djamel DabliDjamel Dabli
Djamel Dabli
HFHélène de Forges
Hélène de Forges
Joel GREFFIERJoel GREFFIER
Joel GREFFIER
Microwave ablation systems allow for performing tumoral destruction in oncology. The objective of this study was to assess the early response and reliability of the microwave ablation zone size at one month for liver, kidney and lung lesions, as compared to the manufacturer’s charts. Patients who underwent microwave ablation with the EmprintTM ablation system for liver, kidney and lung lesions between June 2016 and June 2018 were retrospectively reviewed. Local response and ablation zone size (major, L, and minor, l, axes) were evaluated on the one-month follow-up imaging. Results were compared to the manufacturers’ charts using the Bland–Altman analysis. Fifty-five patients (mean age 68 ± 11 years; 95 lesions) were included. The one-month complete response was 94%. Liver ablations showed a good agreement with subtle, smaller ablation zones (L: −2 ± 5.7 mm; l: −5.2 ± 5.6 mm). Kidney ablations showed a moderate agreement with larger ablations for L (L: 8.69 ± 7.94 mm; l: 0.36 ± 4.77 mm). Lung ablations showed a moderate agreement, with smaller ablations for l (L: −5.45 ± 4.5 mm; l: −9.32 ± 4.72 mm). With 94% of early complete responses, the system showed reliable ablations for liver lesions, but larger ablations for kidney lesions, and smaller for lung lesions.

4 November 2022 in Cancers
Verified
Journal Article
Open access
PDF file
TKTAREK KAMMOUN
TAREK KAMMOUN
EPElodie Prévot
Elodie Prévot
CSChris Serrand
Chris Serrand
RPRomain Perolat
Romain Perolat
HFHélène de Forges
Hélène de Forges
julien frandonjulien frandon
julien frandon
Background: Percutaneous cryoablation with liquid nitrogen is a new technique being used in the treatment of some malignant tumors. Our objective was to assess its feasibility in the ablation of tumor lesions of various sizes and locations. Methods: This retrospective, monocentric study included all consecutive patients who underwent percutaneous cryoablation with liquid nitrogen between December 2019 and March 2021. Cryoablation was performed using 10G or 13G cryoprobes. The ablation volume was measured on post-treatment CT or MRI. Results: 22 patients (24 lesions) were included, 16 of whom were men (73%), while median age was 66 years. The lesions were located in the bone (42%), kidney (29%), soft tissue (17%), lung (8%), or liver (4%). It was feasible in all tumor locations and produced median ablation zones 25 mm in width and 35 mm in length, with a 23 min median freezing time. Freezing duration was correlated with the ice volume (p Spearman = 0.02), but not with the ablation volume (p = 0.11). The average difference between the ablation zone and ice ball sizes were −6.4 mm in width and −7.7 mm in length. Both ice and ablation volumes were larger when using the 10G probe as compared to when the 13G was used. No complications were reported. Discussion: We showed that this technique was safe and feasible in all organs tested. The freezing duration was correlated with the ice ball size, but not with the ablation zone.

Verified
Journal Article
Open access
PDF file
Joel GREFFIERJoel GREFFIER
Joel GREFFIER
Djamel DabliDjamel Dabli
Djamel Dabli
TKTAREK KAMMOUN
TAREK KAMMOUN
JGJean Goupil
Jean Goupil
LBLaure Berny
Laure Berny
julien frandonjulien frandon
julien frandon
Background: This study aimed to retrospectively analyze dosimetric indicators recorded since 2012 for thoracic, abdominal or pelvic embolizations to evaluate the contribution of new tools and technologies in dose reduction. Methods: Dosimetric indicators (dose area product (DAP) and air kerma (AK)) from 1449 embolizations were retrospectively reviewed from August 2012 to March 2022. A total of 1089 embolizations were performed in an older fixed C-Arm system (A1), 222 in a newer fixed C-Arm system (A2) and 138 in a 4DCT system (A3). The embolization procedures were gathered to compare A1, A2 and A3. Results: DAP were significantly lower with A2 compared to A1 for all procedures (median −50% ± 5%, p < 0.05), except for uterine elective embolizations and gonadal vein embolization. The DAP values were significantly lower with A3 than with A1 (p < 0.001). CT scan was used for guidance in 90% of embolization procedures. Conclusions: The last C-Arm technology allowed a median reduction of 50% of the X-ray dose. The implementation of a CT scan inside the IR room allowed for more precise 3D-guidance with no increase of the dose delivered.

28 October 2023 in Cancers
Verified
Journal Article
Open access
PDF file
BMBenjamin Moulin
Benjamin Moulin
TKTAREK KAMMOUN
TAREK KAMMOUN
RARegis Audoual
Regis Audoual
SDStéphane Droupy
Stéphane Droupy
VSVincent Servois
Vincent Servois
julien frandonjulien frandon
julien frandon
Kidney cancer accounts for 3% of adult malignancies and is increasingly detected through advanced imaging techniques, highlighting the need for effective treatment strategies. This retrospective study assessed the safety and efficacy of a new single-probe percutaneous cryoablation system using liquid nitrogen for treating T1a renal cancers. From May 2019 to May 2022, 25 consecutive patients from two academic hospitals, with a median age of 64.8 years [IQR 59; 75.5], underwent cryoablation for 26 T1a renal tumors. These tumors had a median size of 25.3 mm [20; 30.7] and a median RENAL nephrometry score, indicating tumor complexity, of 7 [5; 9]. No major complications arose, but three non-clinically relevant perirenal hematomas were detected on post-procedure CT scans. With a median follow-up of 795 days [573; 1020], the primary local control rate at one month stood was 80.8% (21 out of 26). The five recurrent lesions, which exhibited a higher renal score (p = 0.016), were treated again using cryoablation, achieving a secondary local control rate of 100%. No patient died, and the disease-free survival rate was 92% (23 out of 25). In conclusion, single-probe percutaneous cryoablation emerges as a promising modality for managing small renal masses. Notably, recurrence rates appear influenced by RENAL nephrometry scores, suggesting a need for further research to refine the technique.

Verified
Journal Article
Open access
PDF file
GBGhizlane Touimi Benjelloun
Ghizlane Touimi Benjelloun
MMMalek Mokbli
Malek Mokbli
TKTAREK KAMMOUN
TAREK KAMMOUN
SGSinda Ghabri
Sinda Ghabri
SSSkander Sammoud
Skander Sammoud
julien frandonjulien frandon
julien frandon
Background: Abdominal wall endometriosis (AWE) is a rare but debilitating condition, often occurring in surgical scars after Caesarean sections. It is characterized by cyclic pain and a palpable mass, significantly impacting patients’ quality of life. Traditional treatments, including hormonal therapy and surgery, have limitations, prompting interest in minimally invasive techniques such as cryoablation. This study evaluates the efficacy and safety of percutaneous image-guided single-probe cryoablation using liquid nitrogen for symptomatic AWE. Purpose: To evaluate the effectiveness and safety of percutaneous image-guided single-probe cryoablation using liquid nitrogen in treating symptomatic AWE lesions, with a primary objective to assess pain relief using the Visual Analog Scale (VAS). Materials and Methods: This retrospective, single-center study included 14 patients (23 lesions) treated with percutaneous cryoablation between September 2022 and April 2025. Clinical, imaging (MRI and ultrasound), and procedural data were analyzed. Pain scores (VAS scale) were assessed before treatment and at 3-month follow-up. Hydro- and/or carbo-dissection were used to protect adjacent structures. Response to treatment was evaluated with MRI and clinical follow-up. Statistical analysis was performed using median, range, and percentage calculations, with comparisons made using the Mann–Whitney test. Results: A total of 23 AWE lesions were treated in 14 patients (mean age: 39.6 years). The median lesion volume was 3546 mm3, with a range from 331 mm3 (8 × 4.6 × 9 mm) to 45,448 mm3 (46 × 26 × 38 mm). Most of the lesions were located in the muscle (69.6%, n = 16), while 17.4% (n = 4) involved both muscle and subcutaneous tissue, and 13.0% (n = 3) were purely subcutaneous. Among the 23 treated lesions, 8.7% (n = 2) appeared as purely hemorrhagic, 13.0% (n = 3) as fibrotic, and 78.3% (n = 18) were classified as mixed, based on imaging characteristics. Procedures were performed under general anesthesia in 65% of cases and under sedation in 35%. Hydrodissection was used in 48% of lesions, carbo-dissection in 4%, and combined hydro–carbo-dissection in 26%. A single 13G cryoprobe was used in 83% of cases, and a 10G probe in 17%. The median ablation time was 15 min (range: 6–28 min), and the median total procedure time was 93 min (range: 22–240 min). Pain scores significantly decreased from a median of 8/10 (range: 6–10) before treatment to 0/10 (range: 0–2) at follow-up (p < 0.0001). MRI follow-up confirmed complete coverage of the ablation zone and disappearance of hemorrhagic inclusions in all cases. Two patients (14%) required re-treatment, both with satisfactory outcomes. No peri- or post-procedural complications were observed, and no visible scars were noted. Conclusions: Percutaneous cryoablation using a single probe with liquid nitrogen is a safe and effective treatment for AWE, offering significant pain relief, minimal morbidity, and excellent cosmetic outcomes. It should be considered as part of multidisciplinary care. Further prospective studies with longer follow-up are warranted to confirm these findings.