Losing a hand can significantly impact an individual’s physical and emotional well-being. Prosthetic hands can help restore some function and independence for individuals who have lost a hand. However, the prosthetic hands available on the market are prohibitively expensive, especially for developing countries, such as Indonesia. Commercial electronically powered prosthetic hands can be expensive, having prices ranging from $25,000 to $75,000 and annual maintenance costs ranging from $500 to $3000. In contrast, body-powered prosthetic hands are generally cheaper, ranging from $2000 to $10,000, but are still considered expensive for many people in developing countries. To make prosthetic hands more accessible, we have designed a body-powered prosthetic hand, “Karla”, using affordable materials and with as few components as possible. This report presents our proposed designs, the innovations, the parts in detail, and experiences using the designed prosthetic hand. The highlight of our design is a novel whippletree-like mechanism that utilizes the 3-D space to contract the fingers of the prosthetic hand.
19 March 2018 in IOP Conference Series: Materials Science and Engineering
A manufacture in Bandung produce kind of rubber-based product i.e. trim, rice rollers, shoe soles, etc. After penetrating the shoe soles market, the manufacture has met customer with tight quality control. Based on the past data, defect level of this product was 18.08% that caused the manufacture's loss of time and money. Quality improvement effort was done using six sigma method that included phases of define, measure, analyse, improve, and control (DMAIC). In the design phase, the object's problem and definition were defined. Delphi method was also used in this phase to identify critical factors. In the measure phase, the existing process stability and sigma quality level were measured. Fishbone diagram and failure mode and effect analysis (FMEA) were used in the next phase to analyse the root cause and determine the priority issues. Improve phase was done by designing alternative improvement strategy using 5W1H method. Some improvement efforts were identified, i.e. (i) modifying design of the hanging rack, (ii) create pantone colour book and check sheet, (iii) provide pedestrian line at compound department, (iv) buying stop watch, and (v) modifying shoe soles dies. Some control strategies for continuous improvement were proposed such as SOP or reward and punishment system.
Hippotherapy is a popular rehabilitation method for children with cerebral palsy (CP), which is done by riding an actual horse or a horse riding simulator (HRS) device. Riding a real horse is more expensive than using an HRS device due to its high maintenance cost. However, most HRS devices commonly sold in the market are designed as exercise devices, not rehabilitation devices. Most of them are designed to simulate a horse’s walk, trot, canter, or gallop gait at various speeds. Hippotherapy aims to improve the walking ability of CP patients. Therefore, the device should aim to replicate the walking gait of a healthy human, the end goal of hippotherapy. This problem motivates us to design and build a specialized HRS device replicating the walking gait of a healthy human that is suitable for hippotherapy, which is achievable by simulating a horse walking gait with several adjustments. We first studied and observed the walking gait cycle of a horse, then analyzed and derived a formulation of it. We then continue by designing an HRS device using a single electrical rotational motor and mechanical means to replicate the walking gait of a horse, then tune it to an extent to replicate a human walking gait. To measure the performance of our design, we compare the gait of the user when riding our device versus walking.
1 August 2019 in IOP Conference Series: Materials Science and Engineering
Muslim in Indonesia uses a lot of water to do an ablution activity, and it is not caused by wasteful character of Indonesia's Muslim society, but because of the design of conventional water tap is not intended to conserve water in ablution activity. To solve the problem, a conceptional Muslim ablution eco water tap design was made. The concept of the product is, it has a mechanical based system to create an auto shutdown mechanism. Thus, the water usage for ablution is predicted can be decreased. However, after the first design alpha prototype is built, faults of the design are directly detected. Thus, this paper tries to analyze the first design alpha prototype and suggest a refinement to create the second design. In this paper, two deficiencies from the first design are identified and a second design is proposed.
One of the biggest challenges in arm prosthesis design is to resemble normal hand functionality. Some of arm prosthesis try to mimic all hand movement, while other try to produce several main hand grip patterns. We design a Versatile Gripping Technology (VGT) from a basic whippletree mechanism to produce main hand grip patterns in arm prosthesis. VGT development is the result of abstraction, negation, and systemic variation process of existing solution. To validate VGT, we test it to produce six pattern of hand grip from Southampton Hand Assessment Procedure. VGT capable to produce lateral, power, tip, extension, and spherical grip. In other hand, VGT including the thumb movement and it only use one simple shape moving part. Thus, VGT is effective and efficient. With this result, we argue that abstraction, negation, and systemic variation process of existing solution can create a novel solution and it is applicable in another problem or domain.