Chien-Hung Yeh

Prof. Dr. Chien-Hung Yeh

School of Information and Electronics, Beijing Institute of Technology, Beijing 100081, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2018 in Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
PFPetra Fischer
Petra Fischer
CCChiung Chu Chen
Chiung Chu Chen
YCYa-Ju Chang
Ya-Ju Chang
Chien-Hung YehChien-Hung Yeh
Chien-Hung Yeh
APAlek Pogosyan
Alek Pogosyan
HTHuiling Tan
Huiling Tan
Gait disturbances in Parkinson's disease are commonly refractory to current treatment options and majorly impair patient's quality of life. Auditory cues facilitate gait and prevent motor blocks. We investigated how neural dynamics in the human subthalamic nucleus of Parkinsons's disease patients (14 male, 2 female) vary during stepping and whether rhythmic auditory cues enhance the observed modulation. Oscillations in the beta band were suppressed after ipsilateral heel strikes, when the contralateral foot had to be raised, and reappeared after contralateral heel strikes, when the contralateral foot rested on the floor. The timing of this 20–30 Hz beta modulation was clearly distinct between the left and right subthalamic nucleus, and was alternating within each stepping cycle. This modulation was similar, whether stepping movements were made while sitting, standing, or during gait, confirming the utility of the stepping in place paradigm. During stepping in place, beta modulation increased with auditory cues that assisted patients in timing their steps more regularly. Our results suggest a link between the degree of power modulation within high beta frequency bands and stepping performance. These findings raise the possibility that alternating deep brain stimulation patterns may be superior to constant stimulation for improving parkinsonian gait.SIGNIFICANCE STATEMENTGait disturbances in Parkinson's disease majorly reduce patients' quality of life and are often refractory to current treatment options. We investigated how neural activity in the subthalamic nucleus of patients who received deep brain stimulation surgery covaries with the stepping cycle. 20–30 Hz beta activity was modulated relative to each step, alternating between the left and right STN. The stepping performance of patients improved when auditory cues were provided, which went along with enhanced beta modulation. This raises the possibility that alternating stimulation patterns may also enhance beta modulation and may be more beneficial for gait control than continuous stimulation, which needs to be tested in future studies.

1 December 2019 in Neurobiology of Disease
Verified
Journal Article
Open access
CCChiung-Chu Chen
Chiung-Chu Chen
Chien-Hung YehChien-Hung Yeh
Chien-Hung Yeh
HCHsiao-Lung Chan
Hsiao-Lung Chan
YCYa-Ju Chang
Ya-Ju Chang
PTPo-Hsun Tu
Po-Hsun Tu
PBPeter Brown
Peter Brown
Freezing of gait (FOG) is a disabling clinical phenomenon often found in patients with advanced Parkinson's disease (PD). FOG impairs motor function, causes falls and leads to loss of independence. Whereas dual tasking that distracts patients' attention precipitates FOG, auditory or visual cues ameliorate this phenomenon. The pathophysiology of FOG remains unclear. Previous studies suggest that the basal ganglia are involved in the generation of FOG. Investigation of the modulation of neuronal activities within basal ganglia structures during walking is warranted. To this end, we recorded local field potentials (LFP) from the subthalamic nucleus (STN) while PD patients performed single-task gait (ST) or walked while dual-tasking (DT). An index of FOG (iFOG) derived from trunk accelerometry was used as an objective measure to differentiate FOG-vulnerable gait from normal gait. Two spectral activities recorded from the STN region were associated with vulnerability to freezing. Greater LFP power in the low beta (15-21 Hz) and theta (5-8 Hz) bands were noted during periods of vulnerable gait in both ST and DT states. Whereas the elevation of low beta activities was distributed across STN, the increase in theta activity was focal and found in ventral STN and/or substantia nigra (SNr) in ST. The results demonstrate that low beta and theta band oscillations within the STN area occur during gait susceptible to freezing in PD. They also add to the evidence that narrow band ~18 Hz activity may be linked to FOG.

11 March 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CLChen Lin
Chen Lin
HYHuei-Ming Yeh
Huei-Ming Yeh
Men-Tzung LoMen-Tzung Lo
Men-Tzung Lo
Chien-Hung YehChien-Hung Yeh
Chien-Hung Yeh
CWCheng-Yen Wang
Cheng-Yen Wang
YLYenn-Jiang Lin
Yenn-Jiang Lin
Monitoring fetal heart rate during pregnancy is essential to assist clinicians in making more timely decisions. Non-invasive monitoring of fetal heart activities using abdominal ECGs is useful for diagnosis of heart defects. However, the extracted fetal ECGs are usually too weak to be robustly detected. Thus, it is a necessity to enhance fetal R-peak since their peaks may hidden within the signal due to the immaturity of the fetal cardiovascular system. Therefore, to improve the detection of the fetal heartbeat, a novel fetal R-peak enhancement technique was proposed to statistically generate the weighting mask according to the distribution of the neighboring temporal intervals between each pair of peaks. Two set of simulations were designed to validate the reliability of the method: challenges with different levels of (1) noise contamination and (2) R-peak interval changing rate. The simulation results showed that the weighting mask improve the accuracy of the R-peak detection rate by 25% and decrease false alarm rate by 20% with white noise contamination, and ensure high R-peak detection rate (> 80%), especially with mild noise contamination (noise amplitude ratio < 1.5 and noise rate per minute < 25%). For those simulations with continuous R-peak intervals changing, the masking process can still effectively eliminate noise contamination especially when the amplitude of the sinusoidal fetal R-R intervals lower than 50msec. For the real fetus ECGs, detection rate was increasing by 3.498% whereas false alarm rate was decreasing by 3.933%. Next, we implement the fetal R-peak enhancement technique to investigate fractal regulation and multiscale entropy of the real fetal heartbeat intervals. Both scaling exponent (∼0.6 to ∼1 in scale 4-15) and entropy measure (scale 6-10) increase from with gestational ages (22-40 weeks). The results confirmed fractal slope and complexity of fetal heartbeat intervals can reflect the maturation of fetus organism.

28 June 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
WSWenbin Shi
Wenbin Shi
Chien-Hung YehChien-Hung Yeh
Chien-Hung Yeh
YHYang Hong
Yang Hong
The purpose of this study is to introduce a method in quantifying cross-frequency information transfer to characterize directional couplers between irregular oscillations in complex systems. Importantly, the method should be able to reflect the intrinsic mechanism of interacting oscillations faithfully. Six types of interacting oscillators, including phase-amplitude, amplitude-amplitude, and component-amplitude cross-frequency transfer entropy as well as their inverse transfer entropies, are within our scope in untangling the brain connectivity. Challenges with nonlinear and nonstationary patterns are designed to validate the robustness of the proposed method. We suggest this approach could be effective in identifying driving and responding elements of interacting oscillators across different time scales. Meanwhile, an atlas of interacting oscillators in sleep is constructed. High-frequency amplitude can inversely drive low-frequency phase stronger than the standard phase-amplitude coupling, and the low-frequency amplitude can be the driving force to the high-frequency amplitude in addition to the low-frequency phase. Unlike the standard phase-amplitude coupling, the proposed cross-frequency transfer entropy is applicable to quantify the interactions across phases, amplitudes, or even the components without methodological adjustments. Meanwhile, the exploration of causal relationship enables the identification of the driving force of information flow.

11 October 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
JLJuntong Lyu
Juntong Lyu
WSWenbin Shi
Wenbin Shi
CZChuting Zhang
Chuting Zhang
Chien-Hung YehChien-Hung Yeh
Chien-Hung Yeh
Accurate sleep staging evaluates the quality of sleep, supporting the clinical diagnosis and intervention of sleep disorders and related diseases. Although previous attempts to classify sleep stages have achieved high classification performance, little attention has been paid to integrating the rich information in brain and heart dynamics during sleep for sleep staging. In this study, we propose a generalized EEG and ECG multimodal feature combination to classify sleep stages with high efficiency and accuracy. Briefly, a hybrid features combination in terms of multiscale entropy and intrinsic mode function are used to reflect nonlinear dynamics in multichannel EEGs, along with heart rate variability measures over time/frequency domains, and sample entropy across scales are applied for ECGs. For both the max-relevance and min-redundancy method and principal component analysis were used for dimensionality reduction. The selected features were classified by four traditional machine learning classifiers. Macro-F1 score, macro-geometric mean, and Cohen kappa value are adopted to evaluate the classification performance of each class in an imbalanced dataset. Experimental results show that EEG features contribute more to wake stage classification while ECG features contribute more to deep sleep stages. The proposed combination achieves the highest accuracy of 84.3% and the highest kappa value of 0.794 on the support vector machine in the ISRUC-S3 dataset, suggesting the proposed multimodal features combination is promising in accuracy and efficiency compared to other state-of-the-art methods.

17 January 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YWYining Wang
Yining Wang
WSWenbin Shi
Wenbin Shi
Chien-Hung YehChien-Hung Yeh
Chien-Hung Yeh
Objective : This paper presents a novel method to quantify cardiopulmonary dynamics for automatic sleep apnea detection by integrating the synchrosqueezing transform (SST) algorithm with the standard cardiopulmonary coupling (CPC) method. Methods: Simulated data were designed to validate the reliability of the proposed method, with varying levels of signal bandwidth and noise contamination. Real data were collected from the Physionet sleep apnea database, consisting of 70 single-lead ECGs with expert-labeled apnea annotations on a minute-by-minute basis. Three different signal processing techniques applied to sinus interbeat interval and respiratory time series include short-time Fourier transform, continuous Wavelet transform, and synchrosqueezing transform, respectively. Subsequently, the CPC index was computed to construct sleep spectrograms. Features derived from such spectrogram were used as input to five machine- learning-based classifiers including decision trees, support vector machines, k-nearest neighbors, etc. Results: The simulation results showed that the SST-CPC method is robust to both noise level and signal bandwidth, outperforming Fourier-based and Wavelet-based approaches. Meanwhile, the SST-CPC spectrogram exhibited relatively explicit temporal-frequency biomarkers compared with the rest. Furthermore, by integrating SST-CPC features with common-used heart rate and respiratory features, accuracies for per-minute apnea detection improved from 72% to 83%, validating the added value of CPC biomarkers in sleep apnea detection. Conclusion: The SST-CPC method improves the accuracy of automatic sleep apnea detection and presents comparable performances with those automated algorithms reported in the literature. Significance: The proposed SST-CPC method enhances sleep diagnostic capabilities, and may serve as a complementary tool to the routine diagnosis of sleep respiratory events.