Noora Almarri

Ms. Noora Almarri

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2020 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Yu WuYu Wu
Yu Wu
Dai JiangDai Jiang
Dai Jiang
MHMaryam Habibollahi
Maryam Habibollahi
NANoora Almarri
Noora Almarri
ADAndreas Demosthenous
Andreas Demosthenous
Bioimpedance analysis is a non-invasive and inexpensive technology to investigate the electrical properties of biological tissues. The analysis requires demodulation to extract the real and imaginary parts of the impedance. Conventional systems use complex architectures such as I-Q demodulation. In this paper, a very simple alternative time-to-digital demodulation method or time stamp is proposed. It employs only three comparators to identify or stamp in the time domain, the crossing points of the excitation signal and the measured signal. In a CMOS proof of concept design, the accuracy of impedance magnitude and phase is 97.06% and 98.81% respectively over a bandwidth of 10 kHz to 500 kHz. The effect of fractional-N synthesis is analysed for the counter-based zero crossing phase detector obtaining a finer phase resolution (0.51 at 500 kHz) using a counter clock frequency (f_clk = 12.5 MHz). Because of its circuit simplicity and ease of transmitting the time stamps, the method is very suited to implantable devices requiring low area and power consumption.

26 August 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
FLFangqi Liu
Fangqi Liu
Yu WuYu Wu
Yu Wu
NANoora Almarri
Noora Almarri
MHMaryam Habibollahi
Maryam Habibollahi
HLHenry T Lancashire
Henry T Lancashire
ADAndreas Demosthenous
Andreas Demosthenous
This paper presents a fully implantable closed-loop device for use in freely moving rodents to investigate new treatments for motor neuron disease. The 0.18 µm CMOS integrated circuit comprises 4 stimulators, each featuring 16 channels for optical and electrical stimulation using arbitrary current waveforms at frequencies from 1.5 Hz to 50 kHz, and a bandwidth programmable front-end for neural recording. The implant uses a Qi wireless inductive link which can deliver >100 mW power at a maximum distance of 2 cm for a freely moving rodent. A backup rechargeable battery can support 10 mA continuous stimulation currents for 2.5 hours in the absence of an inductive power link. The implant is controlled by a graphic user interface with broad programmable parameters via a Bluetooth low energy bidirectional data telemetry link. The encapsulated implant is 40 mm × 20 mm × 10 mm. Measured results are presented showing the electrical performance of the electronics and the packaging method.

30 January 2023 in IEEE Open Journal of Circuits and Systems
Verified
Journal Article
Open access
NANoora Almarri
Noora Almarri
Dai JiangDai Jiang
Dai Jiang
PLPeter J. Langlois
Peter J. Langlois
MRMohamad Rahal
Mohamad Rahal
ADAndreas Demosthenous
Andreas Demosthenous
Battery-less active implantable devices are of interest because they offer longer life span and eliminate costly battery replacement surgical interventions. This is possible as a result of advances in inductive power transfer and development of power management circuits to maximize the overall power transfer and provide various voltage levels for multi-functional implantable devices. Rehabilitation therapy using optical stimulation of genetically modified peripheral neurons requires high current loads. Standard rectification topologies are inefficient and have associated voltage drops unsuited for miniaturized implants. This paper presents an integrated power management unit (PMU) for an optical-electrical stimulator to be used in the treatment of motor neurone disease. It includes a power-efficient regulating rectifier with a novel body biased high-speed comparator providing 3.3 V for the operation of the stimulator, a 3-stage latch-up charge pump with 12 V output for the input stage of the optical-electrical stimulator, and 1.8 V for digital control logic. The chip was fabricated in a 0.18 lm CMOS process. Measured results show that for a regulated output of 3.3 V delivering 30.3 mW power, the peak power conversion efficiency is 84.2% at 6.78 MHz inductive link tunable frequency reducing to 70.3% at 13.56 MHz. The charge pump with on chip capacitors has 90.9% measured voltage conversion efficiency.

Verified
Journal Article
Open access
PDF file
NANoora Almarri
Noora Almarri
PLPeter Langlois
Peter Langlois
Dai JiangDai Jiang
Dai Jiang
ADAndreas Demosthenous
Andreas Demosthenous
A power management unit (PMU) is an essential block for diversified multi-functional low-power Internet of Things (IoT) and biomedical electronics. This paper includes a theoretical analysis of a high current, single-stage ac-dc, reconfigurable, dual output, regulating rectifier consisting of pulse width modulation (PWM) and pulse frequency modulation (PFM). The regulating rectifier provides two independently regulated supply voltages of 1.8 V and 3.3 V from an input ac voltage. The PFM control feedback consists of feedback-driven regulation to adjust the driving frequency of the power transistors through adaptive buffers in the active rectifier. The PWM/PFM mode control provides a feedback loop to adjust the conduction duration accurately and minimize power losses. The design also includes an adiabatic charge pump (CP) to provide a higher voltage level. The adiabatic CP consists of latch-up and power-saving topologies to enhance its power efficiency. Simulation results show that the dual regulating rectifier has 94.3% voltage conversion efficiency with an ac input magnitude of 3.5 Vp. The power conversion efficiency of the regulated 3.3 V output voltage is 82.3%. The adiabatic CP has an overall voltage conversion efficiency (VCE) of 92.9% with a total on-chip capacitance of 60 pF. The circuit was designed using 180 nm CMOS technology.

19 October 2023
Verified
Conference Paper
Open access
MHMaryam Habibollahi
Maryam Habibollahi
JLJiayang Li
Jiayang Li
NANoora Almarri
Noora Almarri
Dai JiangDai Jiang
Dai Jiang
HLHenry T Lancashire
Henry T Lancashire
ADAndreas Demosthenous
Andreas Demosthenous
Versatility of neural interfaces is a key factor in the efficacy of bioelectronic solutions for treating neurological and cardiac disorders. High-density and highly selective interfaces demand a small form factor, resulting in very high electrode impedances that require a large compliance voltage. This paper presents the design of a low-noise, electrode-driving ASIC in 180-nm high-voltage CMOS technology to achieve concurrent stimulation and recording for vagus nerve interfaces. Inter-channel crosstalk is minimized using pole-shifting. The ASIC has a variable recording gain of 60 to 74 dB and programmable, stimulating currents of 4 to 124 μA, which account for variations in the electrode characteristics. The ASIC occupies an area of 2.31 mm 2 . Measured results show clear biphasic stimulus pulses ranging in widths from 10 to 500 μs. To address the impact of artifacts on biopotential recording, the recording amplifier has a very low input-referred noise of 2.92 μVrms over a variable bandwidth that ranges from 300 Hz to 1.4 kHz or 6.6 kHz with or without pole shifting, respectively.

19 October 2023
Verified
Conference Paper
Open access
TYTianyang Yao
Tianyang Yao
NANoora Almarri
Noora Almarri
Yu WuYu Wu
Yu Wu
Dai JiangDai Jiang
Dai Jiang
Richard BayfordRichard Bayford
Richard Bayford
ADAndreas Demosthenous
Andreas Demosthenous
This work presents a high-accuracy hand gesture recognition platform for robotic hand control. The platform consists of a flexible 8-electrode band, a high-performance electrical impedance tomography (EIT) system, a compact customised neural network deployed on a laptop and a robotic hand. The EIT system captures the bioimpedance features from muscle contraction and bone movement in the upper arm. After training, the customised neural network can predict hand gestures using bioimpedance features. The visitor will experience smooth control of a robotic hand by performing desired gestures using this demo platform.