Hans Meine

Dr. Hans Meine

Fraunhofer Institute for Digital Medicine, Bremen, Germany
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2023 in Medical Image Analysis
Verified
Journal Article
Open access
MWMartin Wagner
Martin Wagner
BMBeat-Peter Müller-Stich
Beat-Peter Müller-Stich
AKAnna Kisilenko
Anna Kisilenko
DTDuc Tran
Duc Tran
PHPatrick Heger
Patrick Heger
SBSebastian Bodenstedt
Sebastian Bodenstedt
Surgical workflow and skill analysis are key technologies for the next generation of cognitive surgical assistance systems. These systems could increase the safety of the operation through context-sensitive warnings and semi-autonomous robotic assistance or improve training of surgeons via data-driven feedback. In surgical workflow analysis up to 91% average precision has been reported for phase recognition on an open data single-center video dataset. In this work we investigated the generalizability of phase recognition algorithms in a multicenter setting including more difficult recognition tasks such as surgical action and surgical skill. To achieve this goal, a dataset with 33 laparoscopic cholecystectomy videos from three surgical centers with a total operation time of 22 h was created. Labels included framewise annotation of seven surgical phases with 250 phase transitions, 5514 occurences of four surgical actions, 6980 occurences of 21 surgical instruments from seven instrument categories and 495 skill classifications in five skill dimensions. The dataset was used in the 2019 international Endoscopic Vision challenge, sub-challenge for surgical workflow and skill analysis. Here, 12 research teams trained and submitted their machine learning algorithms for recognition of phase, action, instrument and/or skill assessment. F1-scores were achieved for phase recognition between 23.9% and 67.7% (n = 9 teams), for instrument presence detection between 38.5% and 63.8% (n = 8 teams), but for action recognition only between 21.8% and 23.3% (n = 5 teams). The average absolute error for skill assessment was 0.78 (n = 1 team). Surgical workflow and skill analysis are promising technologies to support the surgical team, but there is still room for improvement, as shown by our comparison of machine learning algorithms. This novel HeiChole benchmark can be used for comparable evaluation and validation of future work. In future studies, it is of utmost importance to create more open, high-quality datasets in order to allow the development of artificial intelligence and cognitive robotics in surgery.

1 March 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
AMAnneke Meyer
Anneke Meyer
GCGrzegorz Chlebus
Grzegorz Chlebus
MRMarko Rak
Marko Rak
DSDaniel Schindele
Daniel Schindele
MSMartin Schostak
Martin Schostak
CHChristian Hansen
Christian Hansen

20 May 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GCGrzegorz Chlebus
Grzegorz Chlebus
Hans MeineHans Meine
Hans Meine
STSmita Thoduka
Smita Thoduka
NANasreddin Abolmaali
Nasreddin Abolmaali
BGBram van Ginneken
Bram van Ginneken
ASAndrea Schenk
Andrea Schenk
To compare manual corrections of liver masks produced by a fully automatic segmentation method based on convolutional neural networks (CNN) with manual routine segmentations in MR images in terms of inter-observer variability and interaction time. For testing, patient’s precise reference segmentations that fulfill the quality requirements for liver surgery were manually created. One radiologist and two radiology residents were asked to provide manual routine segmentations. We used our automatic segmentation method Liver-Net to produce liver masks for the test cases and asked a radiologist assistant and one further resident to correct the automatic results. All observers were asked to measure their interaction time. Both manual routine and corrected segmentations were compared with the reference annotations. The manual routine segmentations achieved a mean Dice index of 0.95 and a mean relative error (RVE) of 4.7%. The quality of liver masks produced by the Liver-Net was on average 0.95 Dice and 4.5% RVE. Liver masks resulting from manual corrections of automatically generated segmentations compared to routine results led to a significantly lower inter-observer variability (mean per case absolute RVE difference across observers 0.69%) when compared to manual routine ones (2.75%). The mean interaction time was 2 min for manual corrections and 10 min for manual routine segmentations. The quality of automatic liver segmentations is on par with those from manual routines. Using automatic liver masks in the clinical workflow could lead to a reduction of segmentation time and a more consistent liver volume estimation across different observers.

1 October 2018 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
AHAnnika Hänsch
Annika Hänsch
MSMichael Schwier
Michael Schwier
TGTobias Gass
Tobias Gass
TMTomasz Morgas
Tomasz Morgas
BHBenjamin Haas
Benjamin Haas
HHHorst K. Hahn
Horst K. Hahn
High radiation dose on organs at risk (OAR) during radiotherapy (RT) treatment can have severe side effects. An important set of OAR during treatment of head and neck cancer are the parotid glands, which are a type of salivary glands that are very sensitive to radiation. The most common radiation-induced side effect on the parotid glands is xerostomia (dry mouth), which can significantly decrease life quality.1 Therefore, modern radiotherapy planning requires accurate segmentation of target structures and OAR for precise and highly localized dose planning.2 As manual segmentation of the planning images is very time-consuming and user-dependent, radiotherapy planning could highly benefit from automatic methods for contouring. However, fully automatic segmentation of the parotid glands from computed tomography (CT) images is difficult due to their high variability in shape and appearance and often low soft-tissue contrast to surrounding structures. Because of their anatomical location, they are also prone to be affected by dental metal artifacts.

1 October 2014 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
FHFrank Heckel
Frank Heckel
JMJan Hendrik Moltz
Jan Hendrik Moltz
Hans MeineHans Meine
Hans Meine
BGBenjamin Geisler
Benjamin Geisler
AKAndreas Kießling
Andreas Kießling
HHHorst K. Hahn
Horst K. Hahn
Efficient segmentation editing tools are important components in the segmentation process, as no automatic methods exist that always generate sufficient results. Evaluating segmentation editing algorithms is challenging, because their quality depends on the user’s subjective impression. So far, no established methods for an objective, comprehensive evaluation of such tools exist and, particularly, intermediate segmentation results are not taken into account. We discuss the evaluation of editing algorithms in the context of tumor segmentation in computed tomography. We propose a rating scheme to qualitatively measure the accuracy and efficiency of editing tools in user studies. In order to objectively summarize the overall quality, we propose two scores based on the subjective rating and the quantified segmentation quality over time. Finally, a simulation-based evaluation approach is discussed, which allows a more reproducible evaluation without the need for human input. This automated evaluation complements user studies, allowing a more convincing evaluation, particularly during development, where frequent user studies are not possible. The proposed methods have been used to evaluate two dedicated editing algorithms on 131 representative tumor segmentations. We show how the comparison of editing algorithms benefits from the proposed methods. Our results also show the correlation of the suggested quality score with the qualitative ratings.

6 January 2022 in IEEE Access
Verified
Journal Article
Open access
GCGrzegorz Chlebus
Grzegorz Chlebus
ASAndrea Schenk
Andrea Schenk
HHHorst K. Hahn
Horst K. Hahn
BGBram Van Ginneken
Bram Van Ginneken
Hans MeineHans Meine
Hans Meine
Semantic segmentation neural networks require pixel-level annotations in large quantities to achieve a good performance. In the medical domain, such annotations are expensive because they are time-consuming and require expert knowledge. Active learning optimizes the annotation effort by devising strategies to select cases for labeling that are the most informative to the model. In this work, we propose an uncertainty slice sampling (USS) strategy for the semantic segmentation of 3D medical volumes that selects 2D image slices for annotation and we compare it with various other strategies. We demonstrate the efficiency of USS on a CT liver segmentation task using multisite data. After five iterations, the training data resulting from USS consisted of 2410 slices (4% of all slices in the data pool) compared to 8121(13%), 8641(14%), and 3730(6%) slices for uncertainty volume (UVS), random volume (RVS), and random slice (RSS) sampling, respectively. Despite being trained on the smallest amount of data, the model based on the USS strategy evaluated on 234 test volumes significantly outperformed models trained according to the UVS, RVS, and RSS strategies and achieved a mean Dice index of 0.964, a relative volume error of 4.2%, a mean surface distance of 1.35mm, and a Hausdorff distance of 23.4mm. This was only slightly inferior to 0.967, 3.8%, 1.18mm, and 22.9mm achieved by a model trained on all available data. Our robustness analysis using the 5 th percentile of Dice and the 95 th percentile of the remaining metrics demonstrated that USS not only resulted in the most robust model compared to other strategies, but also outperformed the model trained on all data according to the 5 th percentile of Dice (0.946 vs. 0.945) and the 95 th percentile of mean surface distance (1.92mm vs. 2.03mm).