In this work, singular spectrum analysis is employed to process vibration signals resulting from rolling bearings. A monitoring indicator is defined from the fact that the structure of a signal recorded from a bearing becomes more complex when the bearing becomes defective. This can be explained by the nonstationarity and the nonlinearity induced by the defect. The effects of operating parameters such as load and speed on the indicator are studied. Results demonstrate that the indicator defined in this paper is less sensitive to these parameters than the rms value, a traditional vibratory indicator.
19 March 2007 in Journal of Vibration and Acoustics
Among the advanced techniques of the predictive maintenance, the vibratory analysis proves to be very effective, in particular, for monitoring rotating components such as the bearings. Their damage creates cyclic efforts which are at the origin of the processing of vibratory measurements. This processing can be made by temporal methods, frequential methods, or by time-scale methods using the wavelets for 2 decades. The wavelet transform is a very effective processing, however, the difficulties of application and interpretation of the results slow down their employment. The determination of the parameters of the wavelets makes its use all the more difficult. Moreover, the use of these time-scale methods is very expensive in time computation. This paper proposes a wavelet adapted to the mechanical shock response of a structure with degrees of freedom. In addition, we developed a procedure for analysis of signals by this wavelet which makes it possible to accelerate the process and to improve detection in the case of disturbed signals. This methodology is compared with the traditional time-scale methods and is implemented to detect defects of different sizes on outer rings and inner rings of ball bearings.
Metabolic syndrome (MetS) is a cluster of metabolic abnormalities that increases the cardiovascular risk. Regular physical exercise can promote benefits, but the MetS individuals are demotivated to perform it. Thus, new possibilities are important as an alternative intervention. The whole-body vibration can be considered an exercise modality and would be a safe and low-cost strategy to improve functional parameters of individuals in different clinical conditions. The aim of this exploratory study was to assess effects of whole-body vibration on functional parameters of MetS individuals. The hypothesis of this work was that the whole-body vibration could improve the functionality of MetS individuals. Twenty-two individuals performed the intervention. The vibration frequency varied from 5 to 14 Hz and the peak-to-peak displacements, from 2.5 to 7.5 mm. Each session consisted of one minute-bout of working time followed by a one minute-bout of passive rest in each peak-to-peak displacement for three-times. The whole-body vibration protocol was applied twice per week for 5 weeks. Data from the trunk flexion, gait speed, sit-to-stand test and handgrip strength were collected. Physiological parameters (blood pressure and heart rate) were also evaluated. The Wilcoxon Rank test and Student t-test were used. No significant changes (p > 0.05) were observed in physiological parameters (arterial blood pressure and heart rate). Significant improvements were found in trunk flexion (p = 0.01), gait speed (p = 0.02), sit-to-stand test (p = 0.005) and handgrip strength (p = 0.04) after the whole-body vibration. In conclusion, whole-body vibration may induce biological responses that improve functional parameters in participants with MetS without interfering in physiological parameters, comparing before and after a 5-week whole-body vibration protocol. Register in the Registro Brasileiro de Ensaios Clínicos (ReBEC) with the number RBR 2bghmh (June 6th, 2016) and UTN: U1111–1181-1177. (virgula).
The musculo-skeletal response of athletes to various activities during training exercises has become a critical issue in order to optimize their performance and minimize injuries. However, dynamic and kinematic measures of an athlete’s activity are generally limited by constraints in data collection and technology. Thus, the choice of reliable and accurate sensors is crucial for gathering data in indoor and outdoor conditions. The aim of this study is to validate the use of the accelerometer of a high sampling rate ( ) Inertial Measurement Unit (IMU) in the frame of running activities. To this end, two validation protocols are imposed: a classical one on a shaker, followed by another one during running, the IMU being attached to a test subject. For each protocol, the response of the IMU Accelerometer (IMUA) is compared to a calibrated industrial accelerometer, considered as the gold standard for dynamic and kinematic data collection. The repeatability, impact of signal frequency and amplitude (on shaker) as well as the influence of speed (while running) are investigated. Results reveal that the IMUA exhibits good repeatability. Coefficient of Variation CV is on the shaker and while running. However, the shaker test shows that the IMUA is affected by the signal frequency (error exceeds beyond ), an observation confirmed by the running test. Nevertheless, the IMUA provides a reliable measure in the range 0–100 Hz, i.e., the most relevant part in the energy spectrum over the range 0–150 Hz during running. In our view, these findings emphasize the validity of IMUs for the measurement of acceleration during running.