Fusui Ji

Fusui Ji


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2018 in Clinical Research in Cardiology
Verified
Journal Article
Closed access
PDF file
XYXue Yu
Xue Yu
FJFusui Ji
Fusui Ji
FXFeng Xu
Feng Xu
WZWenduo Zhang
Wenduo Zhang
XWXinyue Wang
Xinyue Wang
FWFang Wang
Fang Wang

16 July 2022 in Journal of Autoimmunity
Verified
Journal Article
Closed access
YLYudong Liu
Yudong Liu
XYXue Yu
Xue Yu
WZWenduo Zhang
Wenduo Zhang
XZXuan Zhang
Xuan Zhang
MWMin Wang
Min Wang
FJFusui Ji
Fusui Ji

13 March 2021 in Cardiovascular Drugs and Therapy
Verified
Journal Article
Open access
PDF file
XYXue Yu
Xue Yu
XWXinyue Wang
Xinyue Wang
FJFusui Ji
Fusui Ji
WZWenduo Zhang
Wenduo Zhang
CYChenguang Yang
Chenguang Yang
FWFang Wang
Fang Wang
Background: Drug-coated balloon (DCB) has been proved efficacy for coronary small vessel disease, but data regarding outcomes of DCB in common de novo lesions (including reference vessel diameter more than 3.0mm) compared with new-generation drug-eluting stent (DES) are lacking. We hypothesized that a DCB-only strategy for coronary de novo lesions would be non-inferior to DES treatment on angiographic outcomes. Methods: In this randomized controlled trial, we compared the effect of DCB with DES on late lumen loss (LLL) at 9-month angiographic follow-up and 12-month major adverse cardiac events (MACEs), including death, non-fatal myocardial infarction, target lesion revascularization (TLR), and target vessel revascularization (TVR). Results: From July 2017 to July 2018, 288 consecutive patients with reference vessel diameter (RVD) between 2.25 and 4.0mm were screened. After proper pre-dilation, 170 patients were enrolled and randomized to the DCB and the DES groups at 1:1 ratio. Seven patients withdrew the consent forms during hospital stay (1 in DCB group, 6 in DES group). Two patients in DCB group underwent bailout stenting due to severe dissection after DCB release. The primary endpoint of 9-month LLL was −0.19±0.49mm with the DCB versus 0.03±0.64mm with the DES. The one-sided 97.5% upper confidence limit of the difference was −0.04mm, achieving non-inferiority of the DCB compared with the DES (P=0.019). The 12-month cumulative MACE rate was similar in the DCB and DES groups (2.44% vs. 6.33%, P=0.226). Conclusions: In this prospective study, the DCB only strategy for de novo lesion was non-inferior to the new-generation DES in terms of 9-month late lumen loss.

9 July 2010 in European Journal of Clinical Investigation
Verified
Journal Article
Closed access
PDF file
DDDa‐Peng Dai
Da‐Peng Dai
XZXiao‐Yang Zhou
Xiao‐Yang Zhou
YXYao Xiao
Yao Xiao
FXFeng Xu
Feng Xu
FSFu‐Cheng Sun
Fu‐Cheng Sun
JCJian-Ping Cai
Jian-Ping Cai

1 November 2002
Verified
Journal Article
Closed access
QHQing He
Qing He
ZYZhiming Yao
Zhiming Yao
XYXue Yu
Xue Yu
WQWanying Qu
Wanying Qu
FSFucheng Sun
Fucheng Sun
YQYijian Qian
Yijian Qian

1 August 2013 in SCIENTIA SINICA Informationis
Verified
Journal Article
Closed access
FJFusui Ji
Fusui Ji
JWJianKang WU
JianKang WU
WZWenDuo Zhang
WenDuo Zhang
BLBing Liu
Bing Liu
YSYingFei SUN
YingFei SUN
FWFang Wang
Fang Wang
It becomes a common understanding that central aortic systolic and/or pulse pressures (CAP) provide direct and accurate prediction for cardiovascular structural damage and cardiovascular outcomes. Existing methods for CAP measurement and estimation, namely, method based on general transfer function, and N-point moving averaging method, are rather empirical, and lack of theoretical foundation. Those methods also have inherent drawback that there are not personalized, and missing individual aortic characteristics. Here in this paper, we present a novel method of model-based central aortic pressure measurement and computing, referred to as MCAP. MCAP has solid theoretical foundation; a novel human aortic network model is proposed and developed based on viscous fluid mechanics theory. In MCAP, model parameters of individuals are computed from measured pulse wave of radial artery and brachial artery, the central aortic - radial artery transfer function is derived from the model, and finally, the central aortic pressure and pulse wave are obtained. We conducted an experiment at Cardiovascular Department of Beijing Hospital. Experimental results on 50 test cases have shown better performance of MCAP with comparison to GTF and N-point average method (rMCAP = 0:9667, rGTF = 0:9025, rNPMA = 0:8099). The MCAP accuracy (Mean(SBP/DBP) =3.9 mmHg/3.6 mmHg, Stdev (SBP/DBP) = 7.7 mmHg/2.9 mmHg) of central artery systolic pressure and diastolic pressure is up to the standard of AAMI (Mean≤65 mmHg, Stdev≤68 mmHg).