Marco Fronda

Dr. Marco Fronda

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
PDF file
MGMarco Gatti
Marco Gatti
FMFilippo Marchisio
Filippo Marchisio
MFMarco Fronda
Marco Fronda
OROsvaldo Rampado
Osvaldo Rampado
RFRiccardo Faletti
Riccardo Faletti
PFPaolo Fonio
Paolo Fonio
Objective: The aim of this study was to evaluate the impact on dose reduction and image quality of the new iterative reconstruction technique: adaptive statistical iterative reconstruction (ASIR-V). Methods: Fifty consecutive oncologic patients acted as case controls undergoing during their follow-up a computed tomography scan both with ASIR and ASIR-V. Each study was analyzed in a double-blinded fashion by 2 radiologists. Both quantitative and qualitative analyses of image quality were conducted. Results: Computed tomography scanner radiation output was 38% (29%–45%) lower (P < 0.0001) for the ASIR-V examinations than for the ASIR ones. The quantitative image noise was significantly lower (P < 0.0001) for ASIR-V. Adaptive statistical iterative reconstruction–V had a higher performance for the subjective image noise (P = 0.01 for 5 mm and P = 0.009 for 1.25 mm), the other parameters (image sharpness, diagnostic acceptability, and overall image quality) being similar (P > 0.05). Conclusions: Adaptive statistical iterative reconstruction–V is a new iterative reconstruction technique that has the potential to provide image quality equal to or greater than ASIR, with a dose reduction around 40%.

1 October 2021 in HPB
Verified
Journal Article
Closed access
CMCristina Mosconi
Cristina Mosconi
MCMarco Calandri
Marco Calandri
MMMariateresa Mirarchi
Mariateresa Mirarchi
GVGiulio Vara
Giulio Vara
ABAndrea D. Breatta
Andrea D. Breatta
RGRita Golfieri
Rita Golfieri

18 March 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
MFMarco Fronda
Marco Fronda
ABAndrea Doriguzzi Breatta
Andrea Doriguzzi Breatta
MGMarco Gatti
Marco Gatti
MCMarco Calandri
Marco Calandri
CMClaudio Maglia
Claudio Maglia
PFPaolo Fonio
Paolo Fonio
Objectives: To investigate the predictive value of four-phase contrast-enhanced CT (CECT) for early complete response (CR) to drug-eluting-bead transarterial chemoembolization (DEB-TACE), with a particular focus on the quantitatively assessed wash-in and wash-out. Methods: A retrospective analysis of preprocedural CECTs was performed for 129 HCC nodules consecutively subjected to DEB-TACE as first-line therapy. Lesion size, location, and margins were recorded. For the quantitative analysis, the following parameters were computed: contrast enhancement ratio (CER) and lesion-to-liver contrast ratio (LLC) as estimates of wash-in; absolute and relative wash-out (WOabs and WOrel) and delayed percentage attenuation ratio (DPAR) as estimates of wash-out. The early radiological response of each lesion was assessed by the mRECIST criteria and dichotomized in CR versus others (partial response, stable disease, and progressive disease). Results: All quantitatively assessed wash-out variables had significantly higher rates for CR lesions (WOabsp = 0.01, WOrelp = 0.01, and DPAR p = 0.00002). However, only DPAR demonstrated an acceptable discriminating ability, quantified by AUC = 0.80 (95% CI0.73–0.88). In particular, nodules with DPAR ≥ 120 showed an odds ratio of 3.3(1.5–7.2) for CR (p = 0.0026). When accompanied by smooth lesion margins, DPAR ≥ 120 lesions showed a 78% CR rate at first follow-up imaging. No significative association with CR was found for quantitative wash-in estimates (CER and LLC). Conclusions: Based on preprocedural CECT, the quantitative assessment of HCC wash-out is useful in predicting early CR after DEB-TACE. Among the different formulas for wash-out quantification, DPAR has the best discriminating ability. When associated, DPAR ≥ 120 and smooth lesion margins are related to relatively high CR rates. Key Points: • A high wash-out rate, quantitatively assessed during preprocedural four-phase contrast-enhanced CT (CECT), is a favorable predictor for early radiological complete response of HCC to drug-eluting-bead chemoembolization (DEB-TACE). • The arterial phase of CECT shows great dispersion of attenuation values among different lesions, even when a standardized protocol is used, limiting its usefulness for quantitative analyses. • Among the different formulas used to quantify the wash-out rate (absolute wash-out, relative wash-out, and delayed percentage attenuation ratio), the latter (DPAR), based only on the delayed phase, is the most predictive (AUC = 0.80), showing a significant association with complete response for values above 120.

19 February 2019 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
MRM. A. Ruffino
M. A. Ruffino
RFR. Faletti
R. Faletti
MFMarco Fronda
Marco Fronda
MGMarco Gatti
Marco Gatti
LBL. Bergamasco
L. Bergamasco
PFP. Fonio
P. Fonio

1 April 2020 in Medicine
Verified
Journal Article
Open access
MRMaria Antonella Ruffino
Maria Antonella Ruffino
MFMarco Fronda
Marco Fronda
SVSara Varello
Sara Varello
ADAndrea Discalzi
Andrea Discalzi
AMAndrea Mancini
Andrea Mancini
PFPaolo Fonio
Paolo Fonio
Endovascular treatment of arterial injuries with stent-graft is a reliable alternative approach in patients not suitable for embolization or at high risk for surgery. The aim of our study was to evaluate the efficacy and the safety of the BeGraft stent-graft, a low-profile balloon expandable covered stent, for emergency endovascular treatment of iatrogenic arterial injuries. Between August 2015 and September 2018, 34 consecutive patients (mean age 71 ± 12 years, 9 females) underwent implantation of BeGraft stent-grafts for iatrogenic arterial injuries (22 active bleedings, 11 pseudoaneurysms, and 1 enteric-iliac fistula). The primary endpoints were technical and clinical success and rates of major and minor complications. The secondary endpoint was the patency of the device during the follow-up. Imaging follow-up was performed by duplex ultrasound and/or computed tomography angiography (according to lesion site/target vessel), at 1-6-12-15 and 24 months. In all 34 patients (100%), the lesion or the defect was effectively excluded with a cumulative amount of 42 stent-grafts. The clinical success was documented in 30/34 patients (88.2%). Neither device- or procedure-related deaths, or major complications occurred. A minor complication was reported in 1 patient (2.9%), successfully treated during the same procedure. Thirty (88.2%) patients were available for a mean follow-up time of 390 ± 168 days (minimum 184, maximum 770), with no observed loss of patency, yielding a 100% Kaplan–Meier cumulative survival patency function. The percentage of patent patients was 30/30 at 6 months, 22/22 at 12 months, and 5/5 at 15 months. Endovascular treatment of iatrogenic arterial injuries with the BeGraft stent-graft is minimally invasive and effective, with good patency rate at midterm follow-up.

21 November 2018 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
RFRiccardo Faletti
Riccardo Faletti
MGMarco Gatti
Marco Gatti
ACAndrea Di Chio
Andrea Di Chio
MFMarco Fronda
Marco Fronda
MAMatteo Anselmino
Matteo Anselmino
PFPaolo Fonio
Paolo Fonio
The purpose of this study was to compare in vitro pineapple juice and a solution of concentrated pineapple juice with a paramagnetic contrast agent in order to determine the feasibility of using the solution of concentrated pineapple juice in vivo for oesophagus visualisation at magnetic resonance angiography (MRA) before the radiofrequency catheter ablation procedure for atrial fibrillation. The pineapple juice was concentrated by a microwave heating evaporation process performed in a domestic microwave oven. Five grams of modified potato starch for every 40 mL of concentrated pineapple juice were added to the concentrated pineapple juice in order to thicken the solution. The solution resulted visually and quantitatively as hyperintense as the contrast agent in vitro (ratio = 1.02). in vivo, no technical difficulties were encountered during the MRA acquisition and a complete enhanced oesophagus was obtained in 37/38 patients (97.4%). The volumetric analysis and the three-dimensional reconstruction were feasible; the quality was rated as diagnostic in every patient. The intensified oesophagus was successfully merged into the electro-anatomical maps in all the patients. In summary, we demonstrated that this technique allows a feasible and safe oesophagus visualisation during MRA.