Eero Salli

Dr. Eero Salli

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2006 in NeuroImage
Verified
Journal Article
Closed access
LTL. Tillikainen
L. Tillikainen
ESEero Salli
Eero Salli
AKA. Korvenoja
A. Korvenoja
HAH.J. Aronen
H.J. Aronen

17 December 2022 in Polymers
Verified
Journal Article
Open access
PDF file
AMArto Merivaara
Arto Merivaara
EKElle Koivunotko
Elle Koivunotko
KMKalle Manninen
Kalle Manninen
TKTuomas Kaseva
Tuomas Kaseva
JMJulia Monola
Julia Monola
MYMarjo Yliperttula
Marjo Yliperttula
Nanofibrillated cellulose (NFC) hydrogel is a versatile biomaterial suitable, for example, for three-dimensional (3D) cell spheroid culturing, drug delivery, and wound treatment. By freeze-drying NFC hydrogel, highly porous NFC structures can be manufactured. We freeze-dried NFC hydrogel and subsequently reconstituted the samples into a variety of concentrations of NFC fibers, which resulted in different stiffness of the material, i.e., different mechanical cues. After the successful freeze-drying and reconstitution, we showed that freeze-dried NFC hydrogel can be used for one-step 3D cell spheroid culturing of primary mesenchymal stem/stromal cells, prostate cancer cells (PC3), and hepatocellular carcinoma cells (HepG2). No difference was observed in the viability or morphology between the 3D cell spheroids cultured in the freeze-dried and reconstituted NFC hydrogel and fresh NFC hydrogel. Furthermore, the 3D cultured spheroids showed stable metabolic activity and nearly 100% viability. Finally, we applied a convolutional neural network (CNN)-based automatic nuclei segmentation approach to automatically segment individual cells of 3D cultured PC3 and HepG2 spheroids. These results provide an application to culture 3D cell spheroids more readily with the NFC hydrogel and a step towards automatization of 3D cell culturing and analysis.

1 May 1999 in Clinical Neurophysiology
Verified
Journal Article
Closed access
HWHeidi Wikström
Heidi Wikström
RRRisto O. Roine
Risto O. Roine
OSOili Salonen
Oili Salonen
KLKatina Buch Lund
Katina Buch Lund
ESEero Salli
Eero Salli
JHJuha Huttunen
Juha Huttunen

24 February 2022 in Journal of Digital Imaging
Verified
Journal Article
Open access
PDF file
TMTeemu Mäkelä
Teemu Mäkelä
OÖOlli Öman
Olli Öman
LHLasse Hokkinen
Lasse Hokkinen
UWUlla Wilppu
Ulla Wilppu
ESEero Salli
Eero Salli
MKMarko Kangasniemi
Marko Kangasniemi
In stroke imaging, CT angiography (CTA) is used for detecting arterial occlusions. These images could also provide information on the extent of ischemia. The study aim was to develop and evaluate a convolutional neural network (CNN)–based algorithm for detecting and segmenting acute ischemic lesions from CTA images of patients with suspected middle cerebral artery stroke. These results were compared to volumes reported by widely used CT perfusion–based RAPID software (IschemaView). A 42-layer-deep CNN was trained on 50 CTA volumes with manually delineated targets. The lower bound for predicted lesion size to reliably discern stroke from false positives was estimated. The severity of false positives and false negatives was reviewed visually to assess the clinical applicability and to further guide the method development. The CNN model corresponded to the manual segmentations with voxel-wise sensitivity 0.54 (95% confidence interval: 0.44–0.63), precision 0.69 (0.60–0.76), and Sørensen–Dice coefficient 0.61 (0.52–0.67). Stroke/nonstroke differentiation accuracy 0.88 (0.81–0.94) was achieved when only considering the predicted lesion size (i.e., regardless of location). By visual estimation, 46% of cases showed some false findings, such as CNN highlighting chronic periventricular white matter changes or beam hardening artifacts, but only in 9% the errors were severe, translating to 0.91 accuracy. The CNN model had a moderately strong correlation to RAPID-reported Tmax > 10 s volumes (Pearson’s r = 0.76 (0.58–0.86)). The results suggest that detecting anterior circulation ischemic strokes from CTA using a CNN-based algorithm can be feasible when accompanied with physiological knowledge to rule out false positives.

14 March 2022 in The Journal of Pediatrics
Verified
Journal Article
Open access
JKJuho Kuula
Juho Kuula
JMJuha Martola
Juha Martola
AHAntti Hakkarainen
Antti Hakkarainen
KRKatri Räikkönen
Katri Räikkönen
SSSauli Savolainen
Sauli Savolainen
NLNina Lundbom
Nina Lundbom
Objectives To assess radiographic brain abnormalities and investigate volumetric differences in adults born preterm at very low birth weight (<1500 g), using siblings as controls. Study design We recruited 79 adult same-sex sibling pairs with one born preterm at very low birth weight and the sibling at term. We acquired 3-T brain magnetic resonance imaging from 78 preterm participants and 72 siblings. A neuroradiologist, masked to participants' prematurity status, reviewed the images for parenchymal and structural abnormalities, and FreeSurfer software 6.0 was used to conduct volumetric analyses. Data were analyzed by linear mixed models. Results We found more structural abnormalities in very low birth weight participants than in siblings (37% vs 13%). The most common finding was periventricular leukomalacia, present in 15% of very low birth weight participants and in 3% of siblings. The very low birth weight group had smaller absolute brain volumes (-0.4 SD) and, after adjusting for estimated intracranial volume, less gray matter (-0.2 SD), larger ventricles (1.5 SD), smaller thalami (-0.6 SD), caudate nuclei (-0.4 SD), right hippocampus (-0.4 SD), and left pallidum (-0.3 SD). We saw no volume differences in total white matter (-0.04 SD; 95% CI, -0.13 to 0.09). Conclusions Preterm very low birth weight adults had a higher prevalence of brain abnormalities than their termborn siblings. They also had smaller absolute brain volumes, less gray but not white matter, and smaller volumes in several gray matter structures.

21 July 2022 in BMC Bioinformatics
Verified
Journal Article
Open access
PDF file
TKTuomas Kaseva
Tuomas Kaseva
BOBahareh Omidali
Bahareh Omidali
EHEero Hippeläinen
Eero Hippeläinen
TMTeemu Mäkelä
Teemu Mäkelä
UWUlla Wilppu
Ulla Wilppu
ESEero Salli
Eero Salli
Background: The segmentation of 3D cell nuclei is essential in many tasks, such as targeted molecular radiotherapies (MRT) for metastatic tumours, toxicity screening, and the observation of proliferating cells. In recent years, one popular method for automatic segmentation of nuclei has been deep learning enhanced marker-controlled watershed transform. In this method, convolutional neural networks (CNNs) have been used to create nuclei masks and markers, and the watershed algorithm for the instance segmentation. We studied whether this method could be improved for the segmentation of densely cultivated 3D nuclei via developing multiple system configurations in which we studied the effect of edge emphasizing CNNs, and optimized H-minima transform for mask and marker generation, respectively.Results: The dataset used for training and evaluation consisted of twelve in vitro cultivated densely packed 3D human carcinoma cell spheroids imaged using a confocal microscope. With this dataset, the evaluation was performed using a cross-validation scheme. In addition, four independent datasets were used for evaluation. The datasets were resampled near isotropic for our experiments. The baseline deep learning enhanced marker-controlled watershed obtained an average of 0.69 Panoptic Quality (PQ) and 0.66 Aggregated Jaccard Index (AJI) over the twelve spheroids. Using a system configuration, which was otherwise the same but used 3D-based edge emphasizing CNNs and optimized H-minima transform, the scores increased to 0.76 and 0.77, respectively. When using the independent datasets for evaluation, the best performing system configuration was shown to outperform or equal the baseline and a set of well-known cell segmentation approaches.Conclusions: The use of edge emphasizing U-Nets and optimized H-minima transform can improve the marker-controlled watershed transform for segmentation of densely cultivated 3D cell nuclei. A novel dataset of twelve spheroids was introduced to the public.