Xin-Da Xu

Dr. Xin-Da Xu

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2022 in Biomolecules
Verified
Journal Article
Open access
PDF file
YZYu Zheng
Yu Zheng
XXXin-Da Xu
Xin-Da Xu
FCFanglu Chi
Fanglu Chi
NCNing Cong
Ning Cong
Ischemia-reperfusion (I/R) injury, uncommon among patients suffering from myocardial infarction, stroke, or acute kidney injury, can result in cell death and organ dysfunction. Previous studies have shown that different types of cell death, including apoptosis, necrosis, and autophagy, can occur during I/R injury. Pyroptosis, which is characterized by cell membrane pore formation, pro-inflammatory cytokine release, and cell burst, and which differentiates itself from apoptosis and necroptosis, has been found to be closely related to I/R injury. Therefore, targeting the signaling pathways and key regulators of pyroptosis may be favorable for the treatment of I/R injury, which is far from adequate at present. This review summarizes the current status of pyroptosis and its connection to I/R in different organs, as well as potential treatment strategies targeting it to combat I/R injury.

20 November 2015 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
PDF file
XNXiaorong Niu
Xiaorong Niu
YZYan Zhang
Yan Zhang
QZQing Zhang
Qing Zhang
XXXin-Da Xu
Xin-Da Xu
PHPeng Han
Peng Han
MXMin Xu
Min Xu
Objective: To investigate the relationship between hearing loss and vestibular dysfunction in patients with sudden sensorineural hearing loss (SSHL). Methods: Clinical data including the symptom of vertigo of 149 SSHL patients were investigated retrospectively. Pure tone audiometry, ocular vestibular-evoked myogenic potential (oVEMP) and cervical vestibular-evoked myogenic potential (cVEMP) evoked by air-conducted sound (ACS), and caloric test were employed for cochlear and vestibular function assessment. The relationship between hearing level and vestibular dysfunction was analyzed. Results: The pure tone averages (PTAs) (mean ± SD) of SSHL patients with and without vertigo were 88.81 ± 21.74 dB HL and 72.49 ± 21.88 dB HL (Z = −4.411, p = 0.000), respectively. The PTAs of SSHL patients with abnormal and normal caloric test were 84.71 ± 22.54 dB HL and 70.41 ± 24.07 dB HL (t = −2.665, p = 0.009), respectively. Conversely, vertigo and abnormal caloric results also happened more frequently in patients with profound hearing loss. However, no consistent tendency could be found among vestibular evoked myogenic potentials (VEMPs) responses or hearing loss. Conclusions: SSHL patients with vertigo or abnormal caloric test displayed worse hearing loss; and vice versa, vertigo and abnormal caloric results happened more frequently in SSHL patients with profound hearing loss.

1 August 2015 in Clinical Neurophysiology
Verified
Journal Article
Closed access
XXXin-Da Xu
Xin-Da Xu
XZXiao-Tong Zhang
Xiao-Tong Zhang
QZQing Zhang
Qing Zhang
JHJuan Hu
Juan Hu
YCYan-Fei Chen
Yan-Fei Chen
MXMin Xu
Min Xu

1 January 2016 in Hearing Research
Verified
Journal Article
Closed access
XXXin-Da Xu
Xin-Da Xu
CDChen-Ru Ding
Chen-Ru Ding
JYJing Yu
Jing Yu
ZHZhao Han
Zhao Han
JGJun Gu
Jun Gu
FCFanglu Chi
Fanglu Chi

1 June 2015 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
XXXin-Da Xu
Xin-Da Xu
QZQing Zhang
Qing Zhang
JHJuan Hu
Juan Hu
YZYan Zhang
Yan Zhang
YCYan-Fei Chen
Yan-Fei Chen
MXMin Xu
Min Xu

18 September 2015 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
PDF file
NGNa Gao
Na Gao
XXXin-Da Xu
Xin-Da Xu
FCFanglu Chi
Fanglu Chi
FZFan-Gang Zeng
Fan-Gang Zeng
QFQian-Jie Fu
Qian-Jie Fu
YJYe Jiang
Ye Jiang
Conclusion: This study described objective and subjective evaluations of the Nurotron® Venus™ Cochlear Implant System and indicated that this system produced a satisfactory performance. Objective: To observe the performance of the Nurotron® Venus™ cochlear implant (CI) system via electrophysiological and psychophysical evaluations. Methods: A 26-electrode CI system was specially designed. The performance of MRI in animal and cadaveric head experiments, EABR in cats experiment, the correlation between ESRT and C level, and psychophysics evaluations in clinical trials were observed. Results: In the animal and cadaveric head experiments, magnet dislocation could not be prevented in the 1.5 T MRI without removal of the internal magnet. The EABR was clearly elicited in cat experiment. In the clinical trial, the ESRT was strongly correlated with C level (p < 0.001). The human clinical trial involving 57 post-lingually deafened native Mandarin-speaking patients was performed. Residual hearing protection in the implanted ear at each audiometric frequency was observed in 27.5–46.3% patients post-operatively. A pitch ranking test revealed that place pitches were generally ordered from apical to basal electrodes. The recognitions of the perceptions of 301 disyllabic words, environment sounds, disyllabic words, and numerals were significantly better than the pre-operative performance and reached plateaus.