Cardiovascular disease is a major cause of death worldwide. New diagnostic tools are needed to provide early detection and intervention to reduce mortality and increase both the duration and quality of life for patients with heart disease. Seismocardiography (SCG) is a technique for noninvasive evaluation of cardiac activity. However, the complexity of SCG signals introduced challenges in SCG studies. Renewed interest in investigating the utility of SCG accelerated in recent years and benefited from new advances in low-cost lightweight sensors, and signal processing and machine learning methods. Recent studies demonstrated the potential clinical utility of SCG signals for the detection and monitoring of certain cardiovascular conditions. While some studies focused on investigating the genesis of SCG signals and their clinical applications, others focused on developing proper signal processing algorithms for noise reduction, and SCG signal feature extraction and classification. This paper reviews the recent advances in the field of SCG.
Accurate estimation of seismocardiographic (SCG) signal features can help successful signal characterization and classification in health and disease. This may lead to new methods for diagnosing and monitoring heart function. Time-frequency distributions (TFD) were often used to estimate the spectrotemporal signal features. In this study, the performance of different TFDs (e.g., short-time Fourier transform (STFT), polynomial chirplet transform (PCT), and continuous wavelet transform (CWT) with different mother functions) was assessed using simulated signals, and then utilized to analyze actual SCGs. The instantaneous frequency (IF) was determined from TFD and the error in estimating IF was calculated for simulated signals. Results suggested that the lowest IF error depended on the TFD and the test signal. STFT had lower error than CWT methods for most test signals. For a simulated SCG, Morlet CWT more accurately estimated IF than other CWTs, but Morlet did not provide noticeable advantages over STFT or PCT. PCT had the most consistently accurate IF estimations and appeared more suited for estimating IF of actual SCG signals. PCT analysis showed that actual SCGs from eight healthy subjects had multiple spectral peaks at 9.20 ± 0.48, 25.84 ± 0.77, 50.71 ± 1.83 Hz (mean ± SEM). These may prove useful features for SCG characterization and classification.
Artificial heart valves may dysfunction, leading to thrombus and/or pannus formations. Computational fluid dynamics is a promising tool for improved understanding of heart valve hemodynamics that quantify detailed flow velocities and turbulent stresses to complement Doppler measurements. This combined information can assist in choosing optimal prosthesis for individual patients, aiding in the development of improved valve designs, and illuminating subtle changes to help guide more timely early intervention of valve dysfunction. In this computational study, flow characteristics around a bileaflet mechanical heart valve were investigated. The study focused on the hemodynamic effects of leaflet immobility, specifically, where one leaflet does not fully open. Results showed that leaflet immobility increased the principal turbulent stresses (up to 400%), and increased forces and moments on both leaflets (up to 600% and 4000%, respectively). These unfavorable conditions elevate the risk of blood cell damage and platelet activation, which are known to cascade to more severe leaflet dysfunction. Leaflet immobility appeared to cause maximal velocity within the lateral orifices. This points to the possible importance of measuring maximal velocity at the lateral orifices by Doppler ultrasound (in addition to the central orifice, which is current practice) to determine accurate pressure gradients as markers of valve dysfunction.
Pneumothorax (PTX) is an abnormal accumulation of air between the lung and the chest wall. It is a relatively common and potentially life-threatening condition encountered in patients who are critically ill or have experienced trauma. Auscultatory signs of PTX include decreased breath sounds during the physical examination. The objective of this exploratory study was to investigate the changes in sound transmission in the thorax due to PTX in humans. Nineteen human subjects who underwent video-assisted thoracic surgery, during which lung collapse is a normal part of the surgery, participated in the study. After subjects were intubated and mechanically ventilated, sounds were introduced into their airways via an endotracheal tube. Sounds were then measured over the chest surface before and after lung collapse. PTX caused small changes in acoustic transmission for frequencies below 400 Hz. A larger decrease in sound transmission was observed from 400 to 600 Hz, possibly due to the stronger acoustic transmission blocking of the pleural air. At frequencies above 1 kHz, the sound waves became weaker and so did their changes with PTX. The study elucidated some of the possible mechanisms of sound propagation changes with PTX. Sound transmission measurement was able to distinguish between baseline and PTX states in this small patient group. Future studies are needed to evaluate this technique in a wider population.
19 March 2018 in Journal of Biomechanical Engineering
Inspiratory flow in a multigeneration pig lung airways was numerically studied at a steady inlet flow rate of 3.2 × 10−4 m3/s corresponding to a Reynolds number of 1150 in the trachea. The model was validated by comparing velocity distributions with previous measurements and simulations in simplified airway geometries. Simulation results provided detailed maps of the axial and secondary flow patterns at different cross sections of the airway tree. The vortex core regions in the airways were visualized using absolute helicity values and suggested the presence of secondary flow vortices where two counter-rotating vortices were observed at the main bifurcation and in many other bifurcations. Both laminar and turbulent flows were considered. Results showed that axial and secondary flows were comparable in the laminar and turbulent cases. Turbulent kinetic energy (TKE) vanished in the more distal airways, which indicates that the flow in these airways approaches laminar flow conditions. The simulation results suggested viscous pressure drop values comparable to earlier studies. The monopodial asymmetric nature of airway branching in pigs resulted in airflow patterns that are different from the less asymmetric human airways. The major daughters of the pig airways tended to have high airflow ratios, which may lead to different particle distribution and sound generation patterns. These differences need to be taken into consideration when interpreting the results of animal studies involving pigs before generalizing these results to humans.
Introduction Minimally invasive intracranial pressure (ICP) screening has long been desired by neurosurgeons. A novel approach deriving ICP from tympanic membrane (TM) pulsation may offer the solution. The ICP waveform appears to be transmitted to the TM by the cochlear aqueduct. The resulting TM infrasonic pulsations can be measured by certain sensors. Elevated ICP alters brain compliance, which appears to yield slower rise times of the TM pulsation waveform. Measurement of this change may be useful in screening for elevated ICP. This paper investigates one such technique. Methods A stethoscope was modified for airtight external ear canal fit; the dome was exchanged for a magnetic reluctance pressure sensor, allowing measurement of TM pulsations. Analog TM pulsations were analyzed by measuring the pulsation's slope ratio between the waveform's downslope and upslope. Seventeen normal subjects (ages 18-32 years) underwent hyperventilation and tilt table testing to induce ICP changes. An algorithm processed this data and predicted the subject's ICP status. Results The slope ratio method showed consistent and stable changes with the expected alterations in ICP from the tilt test and hyperventilation maneuvers. The classification algorithm correctly identified subjects with elevated ICP in 60 of 60 independent recordings on 17 subjects. Conclusion This paper has four conclusions. First, the "brain stethoscope" can detect increased ICP from the TM pulsation waveform in healthy subjects. Second, analysis of the TM waveform using slope ratio calculations is capable of distinguishing normal versus elevated ICP. Third, the tilt and hyperventilation maneuvers showed the expected physiologic trends. Last, further studies are needed on patients with pathological ICP before the brain stethoscope can be implemented into clinical practice.