Linshuai Zhang

Prof. Dr. Linshuai Zhang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
LZLinshuai Zhang
Linshuai Zhang
SGShuoxin Gu
Shuoxin Gu
SGShuoxin Gu
Shuoxin Gu
TTTakashi Tamiya
Takashi Tamiya
A teleoperated robotic catheter operating system is a solution to avoid occupational hazards caused by repeated exposure radiation of the surgeon to X-ray during the endovascular procedures. However, inadequate force feedback and collision detection while teleoperating surgical tools elevate the risk of endovascular procedures. Moreover, surgeons cannot control the force of the catheter/guidewire within a proper range, and thus the risk of blood vessel damage will increase. In this paper, a magnetorheological fluid (MR)-based robot-assisted catheter/guidewire surgery system has been developed, which uses the surgeon’s natural manipulation skills acquired through experience and uses haptic cues to generate collision detection to ensure surgical safety. We present tests for the performance evaluation regarding the teleoperation, the force measurement, and the collision detection with haptic cues. Results show that the system can track the desired position of the surgical tool and detect the relevant force event at the catheter. In addition, this method can more readily enable surgeons to distinguish whether the proximal force exceeds or meets the safety threshold of blood vessels.

26 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LZLinshuai Zhang
Linshuai Zhang
XTXin Tian
Xin Tian
YFYaqi Fan
Yaqi Fan
TJTao Jiang
Tao Jiang
SGShuoxin Gu
Shuoxin Gu
LXlin Xu
lin Xu
In this study, we propose a rehabilitation training system that incorporates active and passive rehabilitation modes to enhance the convenience, efficacy, and safety of rehabilitation training for patients with upper limb hemiplegia. This system facilitates elbow flexion and extension as well as wrist and palm flexion and extension. The experimental results demonstrate that the exoskeleton robot on the affected limb exhibits a rapid response and maintains a highly synchronized movement with the unaffected upper limb equipped with an angle sensor, preserving stability and coordination throughout the movement process without significant delay affecting the overall motion. When the movement of the unaffected upper limb exceeds the predetermined angle threshold, the affected limb promptly initiates a protective mechanism to maintain its current posture. Upon equalization of the angles between the two limbs, the affected limb resumes synchronized movement, thereby ensuring the safety of the rehabilitation training. This research provides some insights into the functional improvements of safe and reliable upper limb exoskeleton rehabilitation training systems.

7 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LZLinshuai Zhang
Linshuai Zhang
SHSiyu Huang
Siyu Huang
JZJinshan Zuo
Jinshan Zuo
SGShuoxin Gu
Shuoxin Gu
LXlin Xu
lin Xu
TJTao Jiang
Tao Jiang
Inadequate force feedback and collision warnings in teleoperated surgical instruments elevate risks during intravascular cannulation. This study introduces an innovative master haptic interface that utilizes magnetorheological (MR) fluid to enhance surgeons’ operational perception during robot-assisted intervention surgery. The system delivers real-time haptic feedback to enhance surgical operational safety and automatically amplifies the feedback force when the contact force on the slave side surpasses the predefined threshold, enabling timely collision alerts. A series of preliminary experiments has been carried out to validate the efficacy of this particular type of haptic interface. The experimental results clearly indicate that the master haptic interface based on MR fluid and carefully designed can effectively enhance the operator’s haptic perception and provide collision alarms in a timely manner with haptic clues, improving the safety and operability of robot intravascular intervention. This research provides some insights into the functional improvements of safe and reliable robot-assisted catheter systems.