Sang Hun Chung

Mr. Sang Hun Chung

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2020 in JCI Insight
Verified
Journal Article
Open access
PDF file
JGJennifer L Goralski
Jennifer L Goralski
SCSang Hun Chung
Sang Hun Chung
TGTyler M. Glass
Tyler M. Glass
ACAgathe S. Ceppe
Agathe S. Ceppe
EAEsther O. Akinnagbe-Zusterzeel
Esther O. Akinnagbe-Zusterzeel
YLYueh Z Lee
Yueh Z Lee
We hypothesized that dynamic perfluorinated gas MRI would sensitively detect mild cystic fibrosis (CF) lung disease. This cross-sectional study enrolled 20 healthy volunteers and 24 stable subjects with CF, including a subgroup of subjects with normal forced expiratory volume in the first second (FEV 1 ; >80% predicted, n = 9). Dynamic fluorine-19–enhanced MRI ( 19 F MRI) were acquired during sequential breath holds while breathing perfluoropropane (PFP) and during gas wash-out. Outcomes included the fraction of lung without significant ventilation (ventilation defect percent, VDP) and time constants that described PFP wash-in and wash-out kinetics. VDP values (mean ± SD) of healthy controls (3.87% ± 2.7%) were statistically different from moderate CF subjects (19.5% ± 15.5%, P = 0.001) but not from mild CF subjects (10.4% ± 9.9%, P = 0.24). In contrast, the fractional lung volume with slow gas wash-out was elevated both in subjects with mild (9.61% ± 4.87%; P = 0.0066) and moderate CF (16.01% ± 5.01%; P = 0.0002) when compared with healthy controls (3.84% ± 2.16%) and distinguished mild from moderate CF ( P = 0.006). 19 F MRI detected significant ventilation abnormalities in subjects with CF. The ability of gas wash-out kinetics to distinguish between healthy and mild CF lung disease subjects makes 19 F MRI a potentially valuable method for the characterization of early lung disease in CF. This study has been registered at ClinicalTrials.gov (NCT03489590).

8 August 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
AMAndrew McCallister
Andrew McCallister
SCSang Hun Chung
Sang Hun Chung
MAMichael Antonacci
Michael Antonacci
MPMargret Z. Powell
Margret Z. Powell
ACAgathe S. Ceppe
Agathe S. Ceppe
JGJennifer L Goralski
Jennifer L Goralski
Purpose: To quantitatively compare dynamic 19F and single breath hyperpolarized 129Xe MRI for the detection of ventilation abnormalities in subjects with mild cystic fibrosis (CF) lung disease.Methods: Ten participants with stable CF and a baseline FEV1 > 70% completed a single imaging session where dynamic 19F and single breath 129Xe lung ventilation images were acquired on a 3T MRI scanner. Ventilation defect percentages (VDP) values between 19F early‐breath, 19F maximum‐ventilation, 129Xe low‐resolution, and 129Xe high‐resolution images were compared. Dynamic 19F images were used to determine gas wash‐in/out rates in regions of ventilation congruency and mismatch between 129Xe and 19F.Results: VDP values from high‐resolution 129Xe images were greater than from low‐resolution images (P = .001), although these values were significantly correlated (r = 0.68, P = .03). Early‐breath 19F VDP and max‐vent 19F VDP also showed significant correlation (r = 0.75, P = .012), with early‐breath 19F VDP values being significantly greater (P < .001). No correlation in VDP values were detected between either 19F method or high‐res 129Xe images. In addition, the location and volume of ventilation defects were often different when comparing 129Xe and 19F images from the same subject. Areas of ventilation congruence displayed the expected ventilation kinetics, while areas of ventilation mismatch displayed abnormally slow gas wash‐in and wash‐out.Conclusion: In CF subjects, ventilation abnormalities are identified by both 19F and HP 129Xe imaging. However, these ventilation abnormalities are not entirely congruent. 19F and HP 129Xe imaging provide complementary information that enable differentiation of normally ventilated, slowly ventilated, and non‐ventilated regions in the lungs.

19 October 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JGJennifer L Goralski
Jennifer L Goralski
SCSang Hun Chung
Sang Hun Chung
ACAgathe S. Ceppe
Agathe S. Ceppe
MPMargret Zeda Powell
Margret Zeda Powell
MSMuthu Sakthivel
Muthu Sakthivel
SDScott H. Donaldson
Scott H. Donaldson
The availability of highly effective CFTR modulators is revolutionizing the treatment of cystic fibrosis (CF) and drastically improving outcomes. MRI-based imaging modalities are now emerging as highly sensitive endpoints, particularly in the setting of mild lung disease. Adult CF patients were recruited from a single center prior to starting treatment with E/T/I. The following studies were obtained before and after one month on treatment: spirometry, multiple breath nitrogen washout (MBW), 1H UTE MRI (structural images) and 19F MRI (ventilation images). Changes between visits were calculated, as were correlations between FEV1, lung clearance index (LCI), MRI structural scores, and MRI-based ventilation descriptors. Eight subjects had complete datasets for evaluation. Consistent with prior clinical trials, FEV1 and LCI improved after 28 days of E/T/I use. 1H UTE MRI detected improvements in bronchiectasis/airway wall thickening score and mucus plugging score after 28 days of therapy. 19F MRI demonstrated improvements in fractional lung volume with slow gas washout time (FLV↑tau2) and ventilation defect percentage (VDP). Improvements in FLV↑tau2 and VDP correlated with improvement in FEV1 (r = 0.81 and 0.86, respectively, p < 0.05). This observational study establishes the ability of 19F MRI and 1H UTE MRI to detect improvements in lung structure and function after E/T/I treatment. This study supports further development of 19F MRI and 1H UTE MRI as outcome measures for cystic fibrosis research and drug development.

13 March 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
SCSang Hun Chung
Sang Hun Chung
KHKhoi Minh Huynh
Khoi Minh Huynh
JGJennifer L. Goralski
Jennifer L. Goralski
YCYong Chen
Yong Chen
PYPew‐Thian Yap
Pew‐Thian Yap
YLYueh Z Lee
Yueh Z Lee

9 November 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SCSang Hun Chung
Sang Hun Chung
ZWZihan Wang
Zihan Wang
TZTianrui Zhao
Tianrui Zhao
ZLZhitao Li
Zhitao Li
CKChase S. Krumpelman
Chase S. Krumpelman
LYLirong Yan
Lirong Yan
Purpose: To propose a spatio‐temporal U‐Net based network (4DST) that exploits both spatial and dynamic information while avoiding memory‐intensive 4D convolutional layers for ASL‐based non‐contrast enhanced 4‐dimensional MR angiography (4D MRA) vessel segmentation. Methods: Pulsed ASL‐based 4D MRA data were collected on 35 healthy volunteers and 5 arteriovenous malformation patients. Spatial only (2D, 3D) and spatio‐temporal U‐Net variations (including the proposed 4DST) were tested. Two recently developed methods, including feature‐based isolation forest and BRAVE‐Net, were used for comparison. Dice‐Sørensen coefficient (DSC), center‐line Dice (clDice), Hausdorff distance (HD), precision, accuracy, specificity, and sensitivity were calculated. Sensitivity was analyzed relative to SNR and arterial transit time (ATT) to explore detectability. From graph analysis, total vessel length, number of branches, and number of endpoints were reported. Results: 4DST achieved the best DSC, clDice, and HD (0.876 ± 0.03, 0.865 ± 0.02, 6.241 ± 0.95, respectively). 4DST outperformed all other models across the SNR range of 1 to 10 and arterial transit time range of 500 to 800 ms in sensitivity. Last, the 4DST segmentations yielded total lengths and the number of branch splits that more closely matched the ground truths compared to the other models. Conclusion: The proposed 4DST network architecture offers an overall improvement in 4D MRA vessel segmentation performance over the compared methods and provides the framework for an end‐to‐end trainable model for spatio‐temporal datasets. Additionally, 4DST requires minimal pre/post‐processing steps, rendering it an attractive solution for pulsed ASL‐based 4D MRA vessel segmentation.

22 October 2026 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
TZTianrui Zhao
Tianrui Zhao
SCSang Hun Chung
Sang Hun Chung
YHYining He
Yining He
ZHZiyi Huang
Ziyi Huang
JTJianing Tang
Jianing Tang
LYLirong Yan
Lirong Yan
Time‐resolved arterial spin labeling (ASL)‐based noncontrast 4D MRA enables visualization of cerebral arterial flow dynamic patterns and holds great potential for evaluating cerebrovascular disease. However, conventional ASL 4D MRA implementations using look‐locker acquisitions are susceptible to progressive RF saturation during extended readouts, leading to substantial ASL signal attenuation and loss of vessel delineation in distal arteries. These limitations potentially hinder a wider clinical translation of 4D MRA, especially when assessment of whole‐brain vascular anatomy and flow dynamics is needed. This study introduces a practical and reliable ASL 4D MRA technique for whole‐brain or large volumetric imaging by integrating pulsed ASL with undersampled multiple overlapping thin‐slab stack‐of‐stars (SOS) golden‐angle radial acquisition. The proposed method was evaluated against conventional single‐slab 4D MRA, 3D time‐of‐flight magnetic resonance angiography (TOF‐MRA), and pseudocontinuous ASL (pCASL)‐based 4D MRA in terms of vessel delineation, blood flow dynamics, and image quality. Compared to the other methods, the proposed method substantially reduced RF saturation effects and preserved signal intensities in distal small arteries, resulting in significantly improved vessel continuity and contrast throughout the cerebral vasculature, as well as reliably capturing complete inflow‐to‐outflow arterial flow dynamics with good scan efficiency and image quality. The proposed technique enables high‐quality, time‐resolved whole‐brain angiography, offering a promising noncontrast imaging tool for comprehensive assessment of cerebral arterial hemodynamics in clinical and research applications.