Khairunisak Abdul Razak

Prof. Dr. Khairunisak Abdul Razak


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
NNNoorhashimah Mohamad Nor
Noorhashimah Mohamad Nor
NRNur Syafinaz Ridhuan
Nur Syafinaz Ridhuan
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
This review covers the progress of nanomaterial-modified electrodes for enzymatic and non-enzymatic glucose biosensors. Fundamental insights into glucose biosensor components and the crucial factors controlling the electrochemical performance of glucose biosensors are discussed in detail. The metal, metal oxide, and hybrid/composite nanomaterial fabrication strategies for the modification of electrodes, mechanism of detection, and significance of the nanomaterials toward the electrochemical performance of enzymatic and non-enzymatic glucose biosensors are compared and comprehensively reviewed. This review aims to provide readers with an overview and underlying concept of producing a reliable, stable, cost-effective, and excellent electrochemical performance of a glucose biosensor.

13 September 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NRNur Syafinaz Ridhuan
Nur Syafinaz Ridhuan
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
ZLZainovia Lockman
Zainovia Lockman
Highly oriented ZnO nanorod (NR) arrays were fabricated on a seeded substrate through a hydrothermal route. The prepared ZnO nanorods were used as an amperometric enzyme electrode, in which glucose oxidase (GOx) was immobilised through physical adsorption. The modified electrode was designated as Nafion/GOx/ZnO NRs/ITO. The morphology and structural properties of the fabricated ZnO nanorods were analysed using field-emission scanning electron microscope and X-ray diffractometer. The electrochemical properties of the fabricated biosensor were studied by cyclic voltammetry and amperometry. Electrolyte pH, electrolyte temperature and enzyme concentration used for immobilisation were the examined parameters influencing enzyme activity and biosensor performance. The immobilised enzyme electrode showed good GOx retention activity. The amount of electroactive GOx was 7.82 × 10−8mol/cm2, which was relatively higher than previously reported values. The Nafion/GOx/ZnO NRs/ITO electrode also displayed a linear response to glucose ranging from 0.05 mM to 1 mM, with a sensitivity of 48.75 µA/mM and a low Michaelis–Menten constant of 0.34 mM. Thus, the modified electrode can be used as a highly sensitive third-generation glucose biosensor with high resistance against interfering species, such as ascorbic acid, uric acid andL-cysteine. The applicability of the modified electrode was tested using human blood samples. Results were comparable with those obtained using a standard glucometer, indicating the excellent performance of the modified electrode.

26 November 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NRNur Syafinaz Ridhuan
Nur Syafinaz Ridhuan
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
ZLZAINOVIA LOCKMAN
ZAINOVIA LOCKMAN
Azlan Abdul AzizAzlan Abdul Aziz
Azlan Abdul Aziz
In this study, zinc oxide (ZnO) nanorod arrays were synthesized using a simple hydrothermal reaction on ZnO seeds/n-silicon substrate. Several parameters were studied, including the heat-treatment temperature to produce ZnO seeds, zinc nitrate concentration, pH of hydrothermal reaction solution, and hydrothermal reaction time. The optimum heat-treatment temperature to produce uniform nanosized ZnO seeds was 400°C. The nanorod dimensions depended on the hydrothermal reaction parameters. The optimum hydrothermal reaction parameters to produce blunt tip-like nanorods (770 nm long and 80 nm in top diameter) were 0.1 M zinc nitrate, pH 7, and 4 h of growth duration. Phase analysis studies showed that all ZnO nanorods exhibited a strong (002) peak. Thus, the ZnO nanorods grew in a c-axis preferred orientation. A strong ultraviolet (UV) emission peak was observed for ZnO nanorods grown under optimized parameters with a low, deep-level emission peak, which indicated high optical property and crystallinity of the nanorods. The produced ZnO nanorods were also tested for their UV-sensing properties. All samples responded to UV light but with different sensing characteristics. Such different responses could be attributed to the high surface-to-volume ratio of the nanorods that correlated with the final ZnO nanorods morphology formed at different synthesis parameters. The sample grown using optimum synthesis parameters showed the highest responsivity of 0.024 A/W for UV light at 375 nm under a 3 V bias.

27 August 2021 in ACS Omega
Verified
Journal Article
Open access
NZNOR DYANA ZAKARIA
NOR DYANA ZAKARIA
MOMuhamad Huzaifah Omar
Muhamad Huzaifah Omar
NKNajahtul Najihah Ahmad Kamal
Najahtul Najihah Ahmad Kamal
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
TSTurgut Sönmez
Turgut Sönmez
HHHairul Hisham Hamzah
Hairul Hisham Hamzah
Electrodeposition is an electrochemical method employed to deposit stable and robust gold nanoparticles (AuNPs) on electrode surfaces for creating chemically modified electrodes (CMEs). The use of several electrodeposition techniques with different experimental parameters allow in obtaining various surface morphologies of AuNPs deposited on the electrode surface. By considering the electrodeposition of AuNPs in various background electrolytes could play an important strategy in finding the most suitable formation of the electrodeposited AuNP films on the electrode surface. This is because different electrode roughnesses can have different effects on the electrochemical activities of the modified electrodes. Thus, in this study, the electrodeposition of AuNPs onto the glassy carbon (GC) electrode surfaces in various aqueous neutral and acidic electrolytes was achieved by using the cyclic voltammetry (CV) technique with no adjustable CV parameters. Then, surface morphologies and electrochemical activities of the electrodeposited AuNPs were investigated using scanning electron microscopy (SEM), atomic force microscopy (AFM), CV, and electrochemical impedance spectroscopy (EIS). The obtained SEM and 3D-AFM images show that AuNPs deposited at the GC electrode prepared in NaNO3 solution form a significantly better, uniform, and homogeneous electrodeposited AuNP film on the GC electrode surface with nanoparticle sizes ranging from ∼36 to 60 nm. Meanwhile, from the electrochemical performances of the AuNP-modified GC electrodes, characterized by using a mixture of ferricyanide and ferrocyanide ions [Fe(CN6)3–/4–], there is no significant difference observed in the case of charge-transfer resistances (Rct) and heterogeneous electron-transfer rate constants (ko), although there are differences in the surface morphologies of the electrodeposited AuNP films. Remarkably, the Rct values of the AuNP-modified GC electrodes are lower than those of the bare GC electrode by 18-fold, as the Rct values were found to be ∼6 Ω (p > 0.001, n = 3). This has resulted in obtaining ko values of AuNP-modified GC electrodes between the magnitude of 10–2 and 10–3 cm s–1, giving a faster electron-transfer rate than that of the bare GC electrode (10–4 cm s–1). This study confirms that using an appropriate supporting background electrolyte plays a critical role in preparing electrodeposited AuNP films. This approach could lead to nanostructures with a more densely, uniformly, and homogeneously electrodeposited AuNP film on the electrode surfaces, albeit utilizing an easy and simple preparation method.

25 September 2021 in Critical Reviews in Analytical Chemistry
Verified
Journal Article
Closed access
NNNoorhashimah Mohamad Nor
Noorhashimah Mohamad Nor
NRNurul Hidayah Ramli
Nurul Hidayah Ramli
HPHemalatha Poobalan
Hemalatha Poobalan
KTKai Qi Tan
Kai Qi Tan
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
Heavy metal pollution has gained global attention due to its high toxicity and non-biodegradability, even at a low level of exposure. Therefore, the development of a disposable electrode that is sensitive, simple, portable, rapid, and cost-effective as the sensor platform in electrochemical heavy metal detection is vital. Disposable electrodes have been modified with nanomaterials so that excellent electrochemical properties can be obtained. This review highlights the recent progress in the development of numerous types of disposable electrodes modified with nanomaterials for electrochemical heavy metal detection. The disposable electrodes made from carbon-based, glass-based, and paper-based electrodes are reviewed. In particular, the analytical performance, fabrication technique, and integration design of disposable electrodes modified with metal (such as gold, tin and bismuth), carbon (such as carbon nanotube and graphene), and metal oxide (such as iron oxide and zinc oxide) nanomaterials are summarized. In addition, the role of the nanomaterials in improving the electrochemical performance of the modified disposable electrodes is discussed. Finally, the current challenges and future prospect of the disposable electrode modified with nanomaterials are summarized.

19 January 2022 in ACS Omega
Verified
Journal Article
Open access
NNNoorhashimah Mohamad Nor
Noorhashimah Mohamad Nor
SASarasijah Arivalakan
Sarasijah Arivalakan
NZNor Dyana Zakaria
Nor Dyana Zakaria
NNNithiyaa Nilamani
Nithiyaa Nilamani
ZLZAINOVIA LOCKMAN
ZAINOVIA LOCKMAN
KRKhairunisak Abdul Razak
Khairunisak Abdul Razak
Carboxyl (−COOH)-stabilized iron oxide nanoparticles (IONPs) synthesized through co-precipitation were used to modify an indium tin oxide (ITO) electrode, which was chemically functionalized with 3-aminopropyltriethoxysilane (APTES) for heavy metal detection. The effect of soaking time (30, 60, 90, and 120 min) of IONP-COOH self-assembled on an APTES-ITO electrode was studied. Cyclic voltammetry and scanning electron microscopy were applied to analyze the electrochemical properties and morphologies of IONP-COOH/APTES-ITO modified electrode. The modified electrodes were then employed for the simultaneous detection of Cd(II) and Pb(II) by using square wave anodic stripping voltammetry. At 90 min of soaking time, excellent electrochemical performance and larger effective surface area (Ae) were obtained. The linear range for the simultaneous detection of Cd(II) and Pb(II) ions using the modified electrode was 10–100 ppb with limits of detection of 0.90 and 0.60 ppb, respectively. The interference study revealed a low interference effect from Cr(III), Hg(II), Zn(II), Cu(II), Mg(II), Na(I), and K(I) toward the simultaneous detection of Cd(II) and Pb(II). Finally, the IONP-COOH/APTES-ITO-modified electrode was applied to analyze seawater samples and was able to simultaneously detect Cd(II) and Pb(II) ions.