Microplastics are particulate water contaminants that are raising concerns regarding their environmental and health impacts. Optical spectroscopy is the gold standard for their detection; however, it has severe limitations such as tens of hours of analysis time and spatial resolution of more than 10 μm, when targeting the production of a 2D map of the microparticle population. In this work, through a single spectrum acquisition, we aim at quickly getting information about the whole population of identical particles, their chemical nature, and their size in a range below 20 μm. To this end, we built a compact setup enabling both attenuated total reflection Fourier transform infrared (ATR-FTIR) and Raman spectroscopy measurement on the same sample for comparison purposes. We used monodisperse polystyrene and poly(methyl methacrylate) microplastic spheres of sizes ranging between 6 and 20 μm, also measured collectively using a bench-top FTIR spectrometer in ATR mode. The ATR-FTIR technique appears to be more sensitive for the smallest particles of 6 μm, while the opposite trend is observed using Raman spectroscopy. We use theoretical modeling to simulate and explain the ripples observed in the measured spectra at the shortest wavelength (higher wavenumber) region, which appears as an indicator of the microparticle dimension. The latter finding opens new perspectives for ATR-FTIR for the identification and classification of populations of nearly identical micro-scale bodies, such as bacteria and other micro-organisms, where the same measured spectrum embeds dual information about the chemical nature and the size.
Water condensation on a surface strongly affects its effective emissivity, especially in the atmospheric window, a wavelength range essential for outdoor applications related to energetically passive cooling and heating. The evolution of emissivity of a silicon surface during dropwise and filmwise water deposition is studied. The evolution of the spectral radiative properties shows that the increase in effective emissivity due to the growth of a droplet pattern is steeper than for a growing water film of equivalent thickness. The change of surface emissivity takes place in the first moments of condensation where droplets as small as 10 µm drastically impact the reflectance of the pristine surface. The upper limit of effective emissivity is reached for a droplet radius or film thickness of 50 µm. During dropwise condensation, effective emissivity is weighted by the drop surface coverage and then remains within an asymptotic maximum value of 0.8, while in case of filmwise condensation, it is shown to reach 0.9 corresponding to water emissivity. Micrometer‐scale spatially‐resolved infrared spectral images enable to correlate the spatial variation of spectral properties to the droplet size and localization. Such findings are of interest to the implementation of moisture‐controlled emissivity tuning and radiative sky‐coolers for dew harvesting.
Miniaturized Fourier transform infrared (FT-IR) spectrometers suffer from limited optical throughput due to their tiny aperture size. Therefore, coherent wideband sources with high brightness can provide an advantage over the wideband thermal radiation sources. However, the former ones are available based on pulsed operation. In this work, we present and study a miniaturized FT-IR spectrometer with pulsed light sources including chopped thermal source, semiconductor optical amplifier, Q-switched and femtosecond mode-locked laser sources. A system model for the FT-IR spectrometer system under a modulated input light source is presented. The model accounts for the relatively high scanning speed of the micro-electro-mechanical system (MEMS) interferometer. The signal-to-noise ratio of the spectrometer, due to the light source modulation, is calculated at different values of modulation repetition rate ranging from 20 Hz to 2 MHz, and duty cycle values ranging from 1% to 50%. An analytical expression for the worst-case repetition rate for the spectrometer system is derived. The model results are verified by experimental measurements showing good agreement with the theoretical expectations. Spectroscopic measurements for CO 2 gas with pressure ranging from 300 mbar to 700 mbar are also performed using a high-repetition rate source, and the measured spectra agree with the simulation results demonstrating the utility of the spectrometer.
In Raman analysis, the substrate material serves very often for signal enhancement, especially when metallic surfaces are involved; however, in other cases, the substrate has an opposite effect as it is the source of a parasitic signal preventing the observation of the sample material of interest. This is particularly true with the advent of microfluidic devices involving either silicon or polymer surfaces. On the other hand, in a vast majority of Raman experiments, the analysis is made on a horizontal support holding the sample of interest. In our paper, we report that a simple tilting of the supporting substrate, in this case, silicon, can drastically decrease and eventually inhibit the Raman signal of the substrate material, leading to an easier observation of the target analyte of the sample, in this case, microplastic particles. This effect is very pronounced especially when looking for tiny particles. Explanation of this trend is provided thanks to a supporting experiment and further numerical simulations that suggest that the lensing effect of the particles plays an important role. These findings may be useful for Raman analysis of other microscale particles having curved shapes, including biological cells.
In this work, we present an optical gyroscope based on hybrid semiconductor-fiber ring laser. The proposed optical gyroscope is a Ring Laser Gyroscope (RLG), in which the laser cavity is a fiber ring of standard single mode fiber where a semiconductor optical amplifier is used as the gain medium for the ring laser. Taking advantage of the bidirectional nature of the ring laser cavity, two counter-propagating waves are supported in the ring cavity. The two waves are identical in terms of their optical resonance frequency due to the reciprocity of the loop in the static position. A frequency shift is introduced between the two counter-propagating waves when the loop is subjected to an angular rotation, known as the Sagnac effect, and the magnitude of the shift is proportional to the rotation rate. Due to the multi-longitudinal mode nature of the constructed ring laser, the rotation sensor optical system parameters are optimized in a trade-off between the sensitivity and the dynamic range. Special signal processing algorithms are developed to enhance the RLG sensitivity. The performance of the RLG is evaluated using a rate table and the Allan variance of the sensor is extracted. The demonstrated RLG has an excellent linear scale factor with a dynamic range up to 40°/sec and a sensitivity down to 0.2°/sec. The RLG noise specifications as extracted from the Allan variance are a bias instability of 3°/h and an angular random walk of 0.5°/Vh.
Mid-infrared Fourier-transform infrared (FT-IR) spectroscopy of liquid biological samples is limited by the high absorption of water in this spectral range, which makes conventional transmission cuvettes unsuitable as their centimeter-scale length is already too big. The most common alternative relies on the use of attenuated total reflection (ATR) accessories, which provide a small interaction path length for light along the interface between the analyte and the expensive ATR crystals. In this work, we address this issue by proposing a disposable and low-cost micro-transmission cell. Its construction relies on a simple technique, which consists of dispersing plastic spherical microparticles in a liquid sample before dispensing it between two pieces of silicon assembled one onto the other and acting as windows for the cell. Consequently, the microparticles act as a spacer of very precise height in-between the two silicon windows. This technique allows easy construction of infrared absorption cells with near-optimum optical interaction path length just by selecting the most appropriate particle size. The concept is demonstrated by measuring the concentration of glucose in aqueous solutions using microspheres of diameter 20 μm then 40 μm and analyzing the corresponding glucose absorption peaks in the wavenumber range 950–1200 cm−1. The performance is compared to that of standard ATR spectroscopy of the same samples. This resulted in a root-mean-square error of cross-validation (RMSECV) of 58.8 mg dl−1 as obtained for transmission measurements by partial least squares (PLS) regression, which is comparable to the RMSECV of 53 mg dl−1 for single-reflection diamond ATR measurements.