Fabian Lickert

Mr. Fabian Lickert

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
FLFabian Lickert
Fabian Lickert
MOMathias Ohlin
Mathias Ohlin
Henrik BruusHenrik Bruus
Henrik Bruus
POPelle Ohlsson
Pelle Ohlsson
A finite-element model is presented for numerical simulation in three dimensions of acoustophoresis of suspended microparticles in a microchannel embedded in a polymer chip and driven by an attached piezoelectric transducer at MHz frequencies. In accordance with the recently introduced principle of whole-system ultrasound resonances, an optimal resonance mode is identified that is related to an acoustic resonance of the combined transducer-chip-channel system and not to the conventional pressure half-wave resonance of the microchannel. The acoustophoretic action in the microchannel is of comparable quality and strength to conventional silicon-glass or pure glass devices. The numerical predictions are validated by acoustic focusing experiments on 5-μm-diameter polystyrene particles suspended inside a microchannel, which was milled into a polymethylmethacrylate chip. The system was driven anti-symmetrically by a piezoelectric transducer, driven by a 30-V peak-to-peak alternating voltage in the range from 0.5 to 2.5 MHz, leading to acoustic energy densities of 13 J/m3 and particle focusing times of 6.6 s.

1 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
FLFabian Lickert
Fabian Lickert
Henrik BruusHenrik Bruus
Henrik Bruus
Massimiliano RossiMassimiliano Rossi
Massimiliano Rossi
Supplying a piezoelectric transducer with constant voltage or constant power during a frequency sweep can lead to different results in the determination of the acoustofluidic resonance frequencies, which are observed when studying the acoustophoretic displacements and velocities of particles suspended in a liquid-filled microchannel. In this work, three cases are considered: (1) Constant input voltage into the power amplifier, (2) constant voltage across the piezoelectric transducer, and (3) constant average power dissipation in the transducer. For each case, the measured and the simulated responses are compared, and good agreement is obtained. It is shown that Case 1, the simplest and most frequently used approach, is largely affected by the impedance of the used amplifier and wiring, so it is therefore not suitable for a reproducible characterization of the intrinsic properties of the acoustofluidic device. Case 2 strongly favors resonances at frequencies yielding the lowest impedance of the piezoelectric transducer, so small details in the acoustic response at frequencies far from the transducer resonance can easily be missed. Case 3 provides the most reliable approach, revealing both the resonant frequency, where the power-efficiency is the highest, as well as other secondary resonances across the spectrum.

26 December 2022 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
WBWilliam Naundrup Bodé
William Naundrup Bodé
FLFabian Lickert
Fabian Lickert
PAPer Augustsson
Per Augustsson
Henrik BruusHenrik Bruus
Henrik Bruus
A method is presented for the determination of complex-valued compression and shear elastic moduli of polymers for ultrasound applications. The resulting values, which are scarcely reported in the literature, are found with uncertainties typically around 1% (real part) and 6% (imaginary part). The method involves a setup consisting of a cm-radius, mm-thick polymer ring glued concentrically to a disk-shaped piezoelectric transducer. The ultrasound electrical-impedance spectrum of the transducer is computed numerically and fitted to measured values as an inverse problem in a wide frequency range, typically from 500 Hz to 5 MHz, both on and off resonance. The method is validated experimentally by ultrasonic through transmission around 1.9 MHz. The method is low cost, not limited to specific geometries and crystal symmetries, and, given the developed software, easy to execute. The method has no obvious frequency limitations before severe attenuation sets in above 100 MHz.

Verified
Journal Article
Open access
PDF file
Komeil SaeedabadiKomeil Saeedabadi
Komeil Saeedabadi
FLFabian Lickert
Fabian Lickert
Henrik BruusHenrik Bruus
Henrik Bruus
GUIDO TOSELLOGUIDO TOSELLO
GUIDO TOSELLO
MCMatteo Calaon
Matteo Calaon
Understanding the relationship between injection molding parameters and the acoustic properties of polymers is crucial for optimizing the design and performance of acoustic-based polymer devices. In this work, the impact of injection molding parameters, such as the injection velocity and packing pressure, on the acoustic parameters of polymers, namely the elastic moduli, is studied. The measurements lead to calculating material parameters, such as the Young’s modulus and Poisson’s ratio, that can be swiftly measured and determined thanks to this method. Polymethyl methacrylate (PMMA) was used as the molding material, and using PMMA LG IG 840, the parts were simulated and injection molded, applying a ‘design of experiment’ (DOE) statistical method. The results indicated a correlation between the injection molding process parameters and the acoustic characteristics, such as the elastic moduli, and a specifically decreasing trend with increase in the injection velocity. Notably, a relative decrease in the Young’s modulus by 1% was observed when increasing the packing pressure from 90MPa to 120MPa. Similarly, a decrease in the Poisson’s ratio of 2.9% was observed when the injection velocity was increased from 16mm/s to 40mm/s. This method can be used to fine-tune the material properties according to the needs of a given application and to facilitate the characterization of different polymer acoustic properties essential for acoustic-based polymer devices.

30 July 2025 in Manufacturing Letters
Verified
Journal Article
Open access
SMSalman Murad
Salman Murad
MHMarvin Heyer
Marvin Heyer
FLFabian Lickert
Fabian Lickert
JSJudith Schlanderer
Judith Schlanderer
DKDaniel Kainz
Daniel Kainz
PJPeter Juelg
Peter Juelg

13 October 2022 in arXiv
Verified
Preprint
Open access
PDF file
WBWilliam Naundrup Bodé
William Naundrup Bodé
FLFabian Lickert
Fabian Lickert
PAPer Augustsson
Per Augustsson
Henrik BruusHenrik Bruus
Henrik Bruus
A method is presented for the determination of complex-valued compression and shear elastic moduli of polymers for ultrasound applications. The resulting values, which are scarcely reported in the literature, are found with uncertainties typically around 1 % (real part) and 6 % (imaginary part). The method involves a setup consisting of a cm-radius, mm-thick polymer ring glued concentrically to a disk-shaped piezoelectric transducer. The ultrasound electrical impedance spectrum of the transducer is computed numerically and fitted to measured values as an inverse problem in a wide frequency range, typically from 500 Hz to 5 MHz, both on and off resonance. The method was validated experimentally by ultrasonic through-transmission around 1.9 MHz. Experimentally, the method is arguably simple and low cost, and it is not limited to specific geometries and crystal symmetries. Moreover, by involving off-resonance frequencies, it allows for determining the imaginary parts of the elastic moduli, equivalent to attenuation coefficients. Finally, the method has no obvious frequency limitations before severe attenuation sets in above 100 MHz.