Jihoon Hong

Dr. Jihoon Hong


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2022 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
EKE. Kim
E. Kim
HCHyun-Hae Cho
Hyun-Hae Cho
SCS.H. Cho
S.H. Cho
BPByunggeon Park
Byunggeon Park
JHJihoon Hong
Jihoon Hong
SLSo Mi Lee
So Mi Lee
BACKGROUND AND PURPOSE: Synthetic MR imaging is a time-efficient technique. However, its rather long scan time can be challenging for children. This study aimed to evaluate the clinical feasibility of accelerated synthetic MR imaging with deep learning–based reconstruction in pediatric neuroimaging and to investigate the impact of deep learning–based reconstruction on image quality and quantitative values in synthetic MR imaging. MATERIALS AND METHODS: This study included 47 children 2.3–14.7 years of age who underwent both standard and accelerated synthetic MR imaging at 3T. The accelerated synthetic MR imaging was reconstructed using a deep learning pipeline. The image quality, lesion detectability, tissue values, and brain volumetry were compared among accelerated deep learning and accelerated and standard synthetic data sets. RESULTS: The use of deep learning–based reconstruction in the accelerated synthetic scans significantly improved image quality for all contrast weightings (P < .001), resulting in image quality comparable with or superior to that of standard scans. There was no significant difference in lesion detectability between the accelerated deep learning and standard scans (P > .05). The tissue values and brain tissue volumes obtained with accelerated deep learning and the other 2 scans showed excellent agreement and a strong linear relationship (all, R2 > 0.9). The difference in quantitative values of accelerated scans versus accelerated deep learning scans was very small (tissue values, <0.5%; volumetry, −1.46%–0.83%). CONCLUSIONS: The use of deep learning–based reconstruction in synthetic MR imaging can reduce scan time by 42% while maintaining image quality and lesion detectability and providing consistent quantitative values. The accelerated deep learning synthetic MR imaging can replace standard synthetic MR imaging in both contrast-weighted and quantitative imaging.

9 January 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
BPByunggeon Park
Byunggeon Park
JLJae-Kwang Lim
Jae-Kwang Lim
KSKyung Min Shin
Kyung Min Shin
JHJihoon Hong
Jihoon Hong
JCJung Guen Cha
Jung Guen Cha
JPJongmin Park
Jongmin Park
Purpose: This study aimed to investigate the impact of FDG PET/CT timing for biopsy site selection in patients with stage IV lung cancer regarding complications and diagnostic yield. Methods: This retrospective analysis was performed on 1297 patients (924 men and 373 women with a mean age of 71.4 ± 10.2 years) who underwent percutaneous needle biopsy (PNB) for stage IV lung cancer diagnosis in two hospitals. Data collected included the patient’s characteristics, order date of the biopsy and PET/CT exams, biopsy target site (lung or non-lung), guidance modality, complications, sample adequacy, and diagnostic success. Based on the order date of the PNB and PET/CT exams, patients were categorized into upfront and delayed PET/CT groups. Results: PNB for non-lung targets resulted in significantly lower rates of minor (8.1% vs. 16.2%), major (0.2% vs. 3.4%), and overall complications (8.3% vs. 19.6%) compared to PNB for lung targets (p < 0.001 for all types of complications). Compared to the delayed PET/CT group, the upfront PET/CT group exhibited a lower probability of lung target selection of PNB (53.9% vs. 67.1%, p < 0.001), including a reduced incidence of major complications (1.0% vs. 2.9%, p = 0.031). Moreover, there was no significant difference in the occurrence of minor and total complications between the two groups. Upfront PET/CT and delayed PET/CT groups showed no significant difference regarding sample adequacy and diagnostic success. Conclusions: Upfront PET/CT may have an impact on the selection of the biopsy site for patients with advanced lung cancer, which could result in a lower rate of major complications with no change in the diagnostic yield. Upfront PET/CT demonstrates potential clinical implications for enhancing the safety of lung cancer diagnosis in clinical practice.

30 December 2022 in Vascular Specialist International
Verified
Journal Article
Open access
PDF file
BYByunghyuk Yu
Byunghyuk Yu
JHJihoon Hong
Jihoon Hong
Byunghyuk Yu and Jihoon Hong. Vasc Specialist Int 2022;38:. https://doi.org/10.5758/vsi.220054

13 June 2024 in Diagnostic and Interventional Radiology
Verified
Journal Article
Open access
JCJung Guen Cha
Jung Guen Cha
JPJongmin Park
Jongmin Park
BPByunggeon Park
Byunggeon Park
SPSeo Young Park
Seo Young Park
SLSo Mi Lee
So Mi Lee
JHJihoon Hong
Jihoon Hong
Single-center 10-year retrospective analysis of Amplatzer Vascular Plug 4 embolization for pulmonary arteriovenous malformations with feeding arteries of <6 mm - Diagnostic and Interventional Radiology

11 July 2022 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
JHJihoon Hong
Jihoon Hong
SLSang Yub Lee
Sang Yub Lee
JLJae-Kwang Lim
Jae-Kwang Lim
JLJongmin Lee
Jongmin Lee
JPJongmin Park
Jongmin Park
DKDonghyeon Kim
Donghyeon Kim
Hong J, et al. Korean J Radiol. 2022 Aug;23(8):794-802. https://doi.org/10.3348/kjr.2022.0140

31 January 2021 in Journal of Yeungnam Medical Science
Verified
Journal Article
Open access
PDF file
JCJung Guen Cha
Jung Guen Cha
SLSang Yub Lee
Sang Yub Lee
JHJihoon Hong
Jihoon Hong
HRHun Kyu Ryeom
Hun Kyu Ryeom
GKGab Chul Kim
Gab Chul Kim
YDYoung Woo Do
Young Woo Do
Lymphorrhea is a rare but potentially severe complication that occurs after various surgical procedures. Untreated lymphorrhea may lead to wound dehiscence, infection, and prolonged hospital stay. Currently, there is no standard effective treatment. Early management usually includes leg elevation, drainage, and pressure dressing. However, these methods are associated with prolonged recovery and high recurrence rates. We report a case of lymphorrhea from a calf wound after endoscopic great saphenous vein (GSV) harvesting for coronary artery bypass grafting (CABG). The patient presented with intractable oozing from the postoperative wound on the right calf. Lymphorrhea perGsisted for 6 weeks despite negative-pressure wound therapy with a long-acting somatostatin. We performed unilateral pedal lymphangiography that confirmed wound lymphorrhea, followed by glue embolization. No recurrence was observed after 8 months of follow-up. This case report demonstrates the successful use of lymphangiography with glue embolization in the control of lymphorrhea after GSV harvesting for CABG.