Background: Predicting beat-to-beat blood pressure has several clinical applications. While most machine learning models focus on accuracy, it is necessary to build models that explain the relationships of hemodynamical parameters with blood pressure without sacrificing accuracy, especially during exercise. Objective: The aim of this study is to use the RuleFit model to measure the importance, interactions, and relationships among several parameters extracted from photoplethysmography (PPG) and electrocardiography (ECG) signals during a dynamic weight-bearing test (WBT) and to assess the accuracy and interpretability of the model results. Methods: RuleFit was applied to hemodynamical ECG and PPG parameters during rest and WBT in six healthy young subjects. The WBT involves holding a 500 g weight in the left hand for 2 min. Blood pressure is taken in the opposite arm before and during exercise thereof. Results: The root mean square error of the model residuals was 4.72 and 2.68 mmHg for systolic blood pressure and diastolic blood pressure, respectively, during rest and 4.59 and 4.01 mmHg, respectively, during the WBT. Furthermore, the blood pressure measurements appeared to be nonlinear, and interaction effects were observed. Moreover, blood pressure predictions based on PPG parameters showed a strong correlation with individual characteristics and responses to exercise. Conclusion: The RuleFit model is an excellent tool to study interactions among variables for predicting blood pressure. Compared to other models, the RuleFit model showed superior performance. RuleFit can be used for predicting and interpreting relationships among predictors extracted from PPG and ECG signals.
Background and Objectives: To compare autonomic and vascular responses during reactive hyperemia (RH) between healthy individuals and patients with sickle cell anemia (SCA). Materials and Methods: Eighteen healthy subjects and 24 SCA patients were subjected to arterial occlusion for 3 min at the lower right limb level. The pulse rate variability (PRV) and pulse wave amplitude were measured through photoplethysmography using the Angiodin® PD 3000 device, which was placed on the first finger of the lower right limb 2 min before (Basal) and 2 min after the occlusion. Pulse peak intervals were analyzed using time–frequency (wavelet transform) methods for high-frequency (HF: 0.15–0.4) and low-frequency (LF: 0.04–0.15) bands, and the LF/HF ratio was calculated. Results: The pulse wave amplitude was higher in healthy subjects compared to SCA patients, at both baseline and post-occlusion (p < 0.05). Time–frequency analysis showed that the LF/HF peak in response to the post-occlusion RH test was reached earlier in healthy subjects compared to SCA patients. Conclusions: Vasodilatory function, as measured by PPG, was lower in SCA patients compared to healthy subjects. Moreover, a cardiovascular autonomic imbalance was present in SCA patients with high sympathetic and low parasympathetic activity in the basal state and a poor response of the sympathetic nervous system to RH. Early cardiovascular sympathetic activation (10 s) and vasodilatory function in response to RH were impaired in SCA patients.