Julia Balog

Dr. Julia Balog

Waters Research Center, Budapest, Hungary
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2017 in Breast Cancer Research
Verified
Journal Article
Open access
PDF file
EJEdward R. St John
Edward R. St John
JBJulia Balog
Julia Balog
JMJames S. McKenzie
James S. McKenzie
MRMerja Rossi
Merja Rossi
ACApril Covington
April Covington
Daniel LeffDaniel Leff
Daniel Leff
Re-operation for positive resection margins following breast-conserving surgery occurs frequently (average = 20–25%), is cost-inefficient, and leads to physical and psychological morbidity. Current margin assessment techniques are slow and labour intensive. Rapid evaporative ionisation mass spectrometry (REIMS) rapidly identifies dissected tissues by determination of tissue structural lipid profiles through on-line chemical analysis of electrosurgical aerosol toward real-time margin assessment. Electrosurgical aerosol produced from ex-vivo and in-vivo breast samples was aspirated into a mass spectrometer (MS) using a monopolar hand-piece. Tissue identification results obtained by multivariate statistical analysis of MS data were validated by histopathology. Ex-vivo classification models were constructed from a mass spectral database of normal and tumour breast samples. Univariate and tandem MS analysis of significant peaks was conducted to identify biochemical differences between normal and cancerous tissues. An ex-vivo classification model was used in combination with bespoke recognition software, as an intelligent knife (iKnife), to predict the diagnosis for an ex-vivo validation set. Intraoperative REIMS data were acquired during breast surgery and time-synchronized to operative videos. A classification model using histologically validated spectral data acquired from 932 sampling points in normal tissue and 226 in tumour tissue provided 93.4% sensitivity and 94.9% specificity. Tandem MS identified 63 phospholipids and 6 triglyceride species responsible for 24 spectral differences between tissue types. iKnife recognition accuracy with 260 newly acquired fresh and frozen breast tissue specimens (normal n = 161, tumour n = 99) provided sensitivity of 90.9% and specificity of 98.8%. The ex-vivo and intra-operative method produced visually comparable high intensity spectra. iKnife interpretation of intra-operative electrosurgical vapours, including data acquisition and analysis was possible within a mean of 1.80 seconds (SD ±0.40). The REIMS method has been optimised for real-time iKnife analysis of heterogeneous breast tissues based on subtle changes in lipid metabolism, and the results suggest spectral analysis is both accurate and rapid. Proof-of-concept data demonstrate the iKnife method is capable of online intraoperative data collection and analysis. Further validation studies are required to determine the accuracy of intra-operative REIMS for oncological margin assessment.

29 November 2022 in Cancers
Verified
Journal Article
Open access
PDF file
Diana MarcusDiana Marcus
Diana Marcus
DCDavid Constable-Phelps
David Constable-Phelps
ASAdele Savage
Adele Savage
JBJulia Balog
Julia Balog
HKHiromi Kudo
Hiromi Kudo
SGSadaf Ghaem-Maghami
Sadaf Ghaem-Maghami
Introduction: Delays in the diagnosis and treatment of endometrial cancer negatively impact patient survival. The aim of this study was to establish whether rapid evaporative ionisation mass spectrometry using the iKnife can accurately distinguish between normal and malignant endometrial biopsy tissue samples in real time, enabling point-of-care (POC) diagnoses. Methods: Pipelle biopsy samples were obtained from consecutive women needing biopsies for clinical reasons. A Waters G2-XS Xevo Q-Tof mass spectrometer was used in conjunction with a modified handheld diathermy (collectively called the ‘iKnife’). Each tissue sample was processed with diathermy, and the resultant surgical aerosol containing ionic lipid species was then analysed, producing spectra. Principal component analyses and linear discriminant analyses were performed to determine variance in spectral signatures. Leave-one-patient-out cross-validation was used to test the diagnostic accuracy. Results: One hundred and fifty patients provided Pipelle biopsy samples (85 normal, 59 malignant, 4 hyperplasia and 2 insufficient), yielding 453 spectra. The iKnife differentiated between normal and malignant endometrial tissues on the basis of differential phospholipid spectra. Cross-validation revealed a diagnostic accuracy of 89% with sensitivity, specificity, positive predictive value and negative predictive value of 85%, 93%, 94% and 85%, respectively. Conclusions: This study is the first to use the iKnife to identify cancer in endometrial Pipelle biopsy samples. These results are highly encouraging and suggest that the iKnife could be used in the clinic to provide a POC diagnosis.

18 September 2024 in British Journal of Cancer
Verified
Journal Article
Open access
PDF file
MKMartin Kaufmann
Martin Kaufmann
PVPierre-Maxence Vaysse
Pierre-Maxence Vaysse
ASAdele Savage
Adele Savage
LKLoes F. S. Kooreman
Loes F. S. Kooreman
NJNatasja Janssen
Natasja Janssen
JBJulia Balog
Julia Balog
Background: While REIMS technology has successfully been demonstrated for the histological identification of ex-vivo breast tumor tissues, questions regarding the robustness of the approach and the possibility of tumor molecular diagnostics still remain unanswered. In the current study, we set out to determine whether it is possible to acquire cross-comparable REIMS datasets at multiple sites for the identification of breast tumors and subtypes. Methods: A consortium of four sites with three of them having access to fresh surgical tissue samples performed tissue analysis using identical REIMS setups and protocols. Overall, 21 breast cancer specimens containing pathology-validated tumor and adipose tissues were analyzed and results were compared using uni- and multivariate statistics on normal, WT and PIK3CA mutant ductal carcinomas. Results: Statistical analysis of data from standards showed significant differences between sites and individual users. However, the multivariate classification models created from breast cancer data elicited 97.1% and 98.6% correct classification for leave-one-site-out and leave-one-patient-out cross validation. Molecular subtypes represented by PIK3CA mutation gave consistent results across sites. Conclusions: The results clearly demonstrate the feasibility of creating and using global classification models for a REIMS-based margin assessment tool, supporting the clinical translatability of the approach.

Verified
Journal Article
Open access
PDF file
AMAdrienn Molnár
Adrienn Molnár
GHGabriel Stefan Horkovics-Kovats
Gabriel Stefan Horkovics-Kovats
NKNóra Kucsma
Nóra Kucsma
ZSZsuzsanna Szegő
Zsuzsanna Szegő
BTBoglárka Tauber
Boglárka Tauber
JBJulia Balog
Julia Balog
Breast cancer, a complex disease with a significant prevalence to form metastases, necessitates novel therapeutic strategies to improve treatment outcomes. Here, we present the results of a comparative molecular study of primary breast tumours, their metastases, and the corresponding primary cell lines using Desorption Electrospray Ionisation (DESI) and Laser-Assisted Rapid Evaporative Ionisation Mass Spectrometry (LA-REIMS) imaging. Our results show that ambient ionisation mass spectrometry technology is suitable for rapid characterisation of samples, providing a lipid- and metabolite-rich spectrum within seconds. Our study demonstrates that the lipidomic fingerprint of the primary tumour is not significantly distinguishable from that of its metastasis, in parallel with the similarity observed between their respective primary cell lines. While significant differences were observed between tumours and the corresponding cell lines, distinct lipidomic signatures and several phospholipids such as PA(36:2), PE(36:1), and PE(P-38:4)/PE(O-38:5) for LA-REIMS imaging and PE(P-38:4)/PE(O-38:5), PS(36:1), and PI(38:4) for DESI-MSI were identified in both tumours and cells. We show that the tumours’ characteristics can be found in the corresponding primary cell lines, offering a promising avenue for assessing tumour responsiveness to therapeutic interventions. A comparative analysis by DESI-MSI and LA-REIMS imaging revealed complementary information, demonstrating the utility of LA-REIMS in the molecular imaging of cancer.

6 August 2025 in Analytical Chemistry
Verified
Journal Article
Open access
DSDaniel Simon
Daniel Simon
GHGabriel Stefan Horkovics-Kováts
Gabriel Stefan Horkovics-Kováts
YXYuchen Xiang
Yuchen Xiang
RBRonan A. Battle
Ronan A. Battle
YWYu Wang
Yu Wang
ZTZoltan Takats
Zoltan Takats
This work demonstrates the combination of ambient laser ablation (LA) with in-source surface-induced declustering, originally developed for rapid evaporative ionization mass spectrometry (REIMS). This combination, termed laser ablation REIMS (LA-REIMS), provides sensitivity, spatial resolution, and chemical coverage comparable to matrix-assisted laser desoprtion ionization (MALDI) but without the requirement for matrix deposition. The atmospheric pressure interface setup was subjected to detailed characterization with regard to geometric and thermal parameters augmented by in-silico flow modeling. The resulting platform was tested using aerosol formed by the infrared laser ablation of tissues. Three different laser systems were successfully employed for ambient mass spectrometric imaging: a carbon dioxide laser (λ = 10.6 μm, τL = ∼100 μs), an optical parametric oscillator (OPO; λ = 2.94 μm, τL = 8 ns), and an optical parametric amplifier (OPA; λ = 3.0 μm, τL = ∼30 ps). Single-cell imaging was achieved using the high-resolving capabilities of the OPA systems, and metabolites and lipids ranging from amino acids through carbohydrates and nuclear bases to complex glycolipids were successfully detected. The technique was also tested as a platform for MS-guided surgery, raising the possibility of using a single technique for generating histological and in vivo data.

17 November 2022 in Metabolites
Verified
Journal Article
Open access
PDF file
MKMartin Kaufmann
Martin Kaufmann
PVPierre-Maxence Vaysse
Pierre-Maxence Vaysse
ASAdele Savage
Adele Savage
AAAla Amgheib
Ala Amgheib
AMAndrás Marton
András Marton
TSTiffany Siegel
Tiffany Siegel
Rapid evaporative ionization mass spectrometry (REIMS) is a direct tissue metabolic profiling technique used to accurately classify tissues using pre-built mass spectral databases. The reproducibility of the analytical equipment, methodology and tissue classification algorithms has yet to be evaluated over multiple sites, which is an essential step for developing this technique for future clinical applications. In this study, we harmonized REIMS methodology using single-source reference material across four sites with identical equipment: Imperial College London (UK); Waters Research Centre (Hungary); Maastricht University (The Netherlands); and Queen’s University (Canada). We observed that method harmonization resulted in reduced spectral variability across sites. Each site then analyzed four different types of locally-sourced food-grade animal tissue. Tissue recognition models were created at each site using multivariate statistical analysis based on the different metabolic profiles observed in the m/z range of 600–1000, and these models were tested against data obtained at the other sites. Cross-validation by site resulted in 100% correct classification of two reference tissues and 69–100% correct classification for food-grade meat samples. While we were able to successfully minimize between-site variability in REIMS signals, differences in animal tissue from local sources led to significant variability in the accuracy of an individual site’s model. Our results inform future multi-site REIMS studies applied to clinical samples and emphasize the importance of carefully-annotated samples that encompass sufficient population diversity.