Yang Zhixiong

Prof. Yang Zhixiong

Kunming Institute of Physics, Kunming, Yunnan, China
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
YZYang Zhixiong
Yang Zhixiong
BWBoyang Wang
Boyang Wang
MYMingyao Yuan
Mingyao Yuan
YZYang Zhixiong
Yang Zhixiong
CYChunchao Yu
Chunchao Yu
WZWeijian Zheng
Weijian Zheng
During industrial operations and in confined places, carbon monoxide (CO) may collect in harmful proportions if ventilation is insufficient or appliances are not properly maintained. When the concentration of CO is too high, it might result in suffocation, coma, or even death. The detection of tiny concentrations of CO plays an important role in safe production. Due to the selective absorption of specific wavelengths of light by gas molecules, lasers have a wide range of applications in the field of gas detection. In this paper, a tunable diode laser absorption spectroscopy (TDLAS) system for CO detection was constructed using an interband cascaded laser (ICL) with a central wavelength of 4.625 μm. The modulated signal generated by the FPGA module was output to the laser controller to modulate the laser. The signal received by the detector was input to the FPGA module. After lock-in amplification, the second harmonic signal of high frequency modulation was output. Several concentrations of CO that were dispersed via static gas distribution were identified. A CO detection system with an open optical path was constructed, and the detection distance was about 8 m. The minimum detectable concentration is around 10.32 ppmm. The concentration of CO in the open optical path was 510.6 ppmm, according to the calibration of the detected concentration. The remote detection system based on TDLAS using an ICL can be used to monitor CO in the open optical path.

15 January 2023 in Toxics
Verified
Journal Article
Open access
PDF file
KLKun Li
Kun Li
SDShaoli Duan
Shaoli Duan
LPLingling Pang
Lingling Pang
WLWeilai Li
Weilai Li
YZYang Zhixiong
Yang Zhixiong
CYChunchao Yu
Chunchao Yu
Environmental monitoring, public safety, safe production, and other areas all benefit greatly from the use of gas detection technologies. The infrared image of a gas could be used to determine its type from a long distance in gas detection. The infrared image can show the spatial distribution of the gas cloud and the background, allowing for long-distance and non-contact detection during safety production and hazardous chemical accident rescue. In this study, a gas detection system based on multispectral infrared imaging is devised, which can detect a variety of gases and determine the types of gas by separating the infrared radiation. It is made up of an imaging optical system, an uncooled focal plane detector, a filter controller, and a data gathering and processing system. The resolution of the infrared image is 640 × 512 and the working band of the system is 6.5~15 μm. The system can detect traces of pollutants in ambient air or gas clouds at higher concentrations. Ammonia, sulfur hexafluoride, methane, sulfur dioxide, and dimethyl methyl phosphonate were all successfully detected in real time. Ammonia clouds could be detected at a distance of 1124.5 m.

10 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YZYang Zhixiong
Yang Zhixiong
KLKun Li
Kun Li
CYChunchao Yu
Chunchao Yu
MYMingyao Yuan
Mingyao Yuan
BWBoyang Wang
Boyang Wang
JFJie Feng
Jie Feng
It is important to obtain information on an instantaneous target. A high-speed camera can capture a picture of an immediate scene, but spectral information about the object cannot be retrieved. Spectrographic analysis is a key tool for identifying chemicals. Detecting dangerous gas quickly can help ensure personal safety. In this paper, a temporally and spatially modulated long-wave infrared (LWIR)-imaging Fourier transform spectrometer was used to realize hyperspectral imaging. The spectral range was 700~1450 cm−1 (7~14.5 μm). The frame rate of infrared imaging was 200 Hz. The muzzle-flash area of guns with calibers of 5.56 mm, 7.62 mm, and 14.5 mm were detected. LWIR images of muzzle flash were obtained. Spectral information on muzzle flash was obtained using instantaneous interferograms. The main peak of the spectrum of the muzzle flash appeared at 970 cm−1 (10.31 μm). Two secondary peaks near 930 cm−1 (10.75 μm) and 1030 cm−1 (9.71 μm) were observed. Radiance and brightness temperature were also measured. The spatiotemporal modulation of the LWIR-imaging Fourier transform spectrometer provides a new method for rapid spectral detection. The high-speed identification of hazardous gas leakage can ensure personal safety.

18 December 2014
Verified
Conference Paper
Closed access
PDF file
YZYang Zhixiong
Yang Zhixiong
CYChunchao Yu
Chunchao Yu
WZWeijian Zheng
Weijian Zheng
ZLZhenggang Lei
Zhenggang Lei
MYMin Yan
Min Yan
PZPeizhong Zhang
Peizhong Zhang

7 November 2018
Verified
Conference Paper
Closed access
PDF file
WZWei-Jian Zheng
Wei-Jian Zheng
YZYang Zhixiong
Yang Zhixiong
FXFei Xia
Fei Xia
ZXZongze Xia
Zongze Xia
ZLZhenggang Lei
Zhenggang Lei
CYChunchao Yu
Chunchao Yu
Infrared radiomentric calibration is of critical importance for information quantification of remote sensing of environment at infrared spectrum. In the quantitative analysis, the calibration of the measured spectra is very important. LWIR Interferometric Hyperspectral Imager Spectrometer Prototype (CHIPED-1) is developed for studying Radiation Calibration. Two-point linear calibration method is carried out for the spectrometer by using blackbody respectively. Firstly, relative intensity is converted to the absolute radiation lightness of the object. Then, radiation intensity of the object is converted the brightness temperature spectrum by the method of brightness temperature. The result indicated that this method of Radiation Calibration calibration was very good. This calibration method is of significance to the further analysis of atmospheric transmission and the retrieval of the concentration of infrared chemical gas in atmosphere.