Xinyu Liu

Xinyu Liu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in Nature Biomedical Engineering
Verified
Journal Article
Open access
PDF file
XLXinyu Liu
Xinyu Liu
LJLiqin Jiang
Liqin Jiang
MKMengyuan Ke
Mengyuan Ke
ISIan A. Sigal
Ian A. Sigal
JCJacqueline Chua
Jacqueline Chua
LSLeopold Schmetterer
Leopold Schmetterer
In myopic eyes, pathological remodelling of collagen in the posterior sclera has mostly been observed ex vivo. Here we report the development of triple-input polarization-sensitive optical coherence tomography (OCT) for measuring posterior scleral birefringence. In guinea pigs and humans, the technique offers superior imaging sensitivities and accuracies than dual-input polarization-sensitive OCT. In 8-week-long studies with young guinea pigs, scleral birefringence was positively correlated with spherical equivalent refractive errors and predicted the onset of myopia. In a cross-sectional study involving adult individuals, scleral birefringence was associated with myopia status and negatively correlated with refractive errors. Triple-input polarization-sensitive OCT may help establish posterior scleral birefringence as a non-invasive biomarker for assessing the progression of myopia.

19 November 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
KLKaicheng Liang
Kaicheng Liang
XLXinyu Liu
Xinyu Liu
SCSi Chen
Si Chen
JXJun Xie
Jun Xie
WLWei Qing Lee
Wei Qing Lee
HLHwee Kuan Lee
Hwee Kuan Lee
A resolution enhancement technique for optical coherence tomography (OCT), based on Generative Adversarial Networks (GANs), was developed and investigated. GANs have been previously used for resolution enhancement of photography and optical microscopy images. We have adapted and improved this technique for OCT image generation. Conditional GANs (cGANs) were trained on a novel set of ultrahigh resolution spectral domain OCT volumes, termed micro-OCT, as the high-resolution ground truth (∼1 μm isotropic resolution). The ground truth was paired with a low-resolution image obtained by synthetically degrading resolution 4x in one of (1-D) or both axial and lateral axes (2-D). Cross-sectional image (B-scan) volumes obtained from in vivo imaging of human labial (lip) tissue and mouse skin were used in separate feasibility experiments. Accuracy of resolution enhancement compared to ground truth was quantified with human perceptual accuracy tests performed by an OCT expert. The GAN loss in the optimization objective, noise injection in both the generator and discriminator models, and multi-scale discrimination were found to be important for achieving realistic speckle appearance in the generated OCT images. The utility of high-resolution speckle recovery was illustrated by an example of micro-OCT imaging of blood vessels in lip tissue. Qualitative examples applying the models to image data from outside of the training data distribution, namely human retina and mouse bladder, were also demonstrated, suggesting potential for cross-domain transferability. This preliminary study suggests that deep learning generative models trained on OCT images from high-performance prototype systems may have potential in enhancing lower resolution data from mainstream/commercial systems, thereby bringing cutting-edge technology to the masses at low cost.

4 May 2024 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
VBValentina Bellemo
Valentina Bellemo
ADAnkit Kumar Das
Ankit Kumar Das
SSSyna Sreng
Syna Sreng
JCJacqueline Chua
Jacqueline Chua
DWDamon Wong
Damon Wong
LSLeopold Schmetterer
Leopold Schmetterer
: Spectral-domain optical coherence tomography (SDOCT) is the gold standard of imaging the eye in clinics. Penetration depth with such devices is, however, limited and visualization of the choroid, which is essential for diagnosing chorioretinal disease, remains limited. Whereas swept-source OCT (SSOCT) devices allow for visualization of the choroid these instruments are expensive and availability in praxis is limited. We present an artificial intelligence (AI)-based solution to enhance the visualization of the choroid in OCT scans and allow for quantitative measurements of choroidal metrics using generative deep learning (DL). Synthetically enhanced SDOCT B-scans with improved choroidal visibility were generated, leveraging matching images to learn deep anatomical features during the training. Using a single-center tertiary eye care institution cohort comprising a total of 362 SDOCT-SSOCT paired subjects, we trained our model with 150,784 images from 410 healthy, 192 glaucoma, and 133 diabetic retinopathy eyes. An independent external test dataset of 37,376 images from 146 eyes was deployed to assess the authenticity and quality of the synthetically enhanced SDOCT images. Experts’ ability to differentiate real versus synthetic images was poor (47.5% accuracy). Measurements of choroidal thickness, area, volume, and vascularity index, from the reference SSOCT and synthetically enhanced SDOCT, showed high Pearson’s correlations of 0.97 [95% CI: 0.96–0.98], 0.97 [0.95–0.98], 0.95 [0.92–0.98], and 0.87 [0.83–0.91], with intra-class correlation values of 0.99 [0.98–0.99], 0.98 [0.98–0.99], and 0.95 [0.96–0.98], 0.93 [0.91–0.95], respectively. Thus, our DL generative model successfully generated realistic enhanced SDOCT data that is indistinguishable from SSOCT images providing improved visualization of the choroid. This technology enabled accurate measurements of choroidal metrics previously limited by the imaging depth constraints of SDOCT. The findings open new possibilities for utilizing affordable SDOCT devices in studying the choroid in both healthy and pathological conditions.

17 September 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
QXQiaozhou Xiong
Qiaozhou Xiong
NWNanshuo Wang
Nanshuo Wang
XLXinyu Liu
Xinyu Liu
SCSi Chen
Si Chen
CBCilwyn S. Braganza
Cilwyn S. Braganza
MVMartin Villiger
Martin Villiger
We observed that the polarization state of light after round-trip propagation through a birefringent medium frequently aligns with the employed input polarization state ‘mirrored’ by the horizontal plane of the Poincaré sphere. We explored the predisposition for this mirror state and evidence that it constrains the evolution of polarization states as a function of the round-trip depth into weakly scattering birefringent samples, as measured with polarization-sensitive optical coherence tomography (PS-OCT). Combined with spectral variations in the polarization state transmitted through system components, we demonstrate how this constraint enables measurement of depth-resolved birefringence using only a single input polarization state, which offers a critical simplification compared to conventional PS-OCT employing two input states.

10 August 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
GJGeorgia L. Jones
Georgia L. Jones
QXQiaozhou Xiong
Qiaozhou Xiong
XLXinyu Liu
Xinyu Liu
BBBrett E. Bouma
Brett E. Bouma
MVMartin Villiger
Martin Villiger
Intravascular polarimetry with catheter-based polarization-sensitive optical coherence tomography (PS-OCT) complements the high-resolution structural tomograms of OCT with morphological contrast available through polarimetry. Its clinical translation has been complicated by the need for modification of conventional OCT hardware to enable polarimetric measurements. Here, we present a signal processing method to reconstruct the polarization properties of tissue from measurements with a single input polarization state, bypassing the need for modulation or multiplexing of input states. Our method relies on a polarization symmetry intrinsic to round-trip measurements and uses the residual spectral variation of the polarization states incident on the tissue to avoid measurement ambiguities. We demonstrate depth-resolved birefringence and optic axis orientation maps reconstructed from in-vivo data of human coronary arteries. We validate our method through comparison with conventional dual-input state measurements and find a mean cumulative retardance error of 13.2deg without observable bias. The 95% limit of agreement between depth-resolved birefringence is 2.80 · 10−4, which is less than the agreement between two repeat pullbacks of conventional PS-OCT (3.14 · 10−4), indicating that the two methods can be used interchangeably. The hardware simplification arising from using a single input state may be decisive in realizing the potential of polarimetric measurements for assessing coronary atherosclerosis in clinical practice.

10 December 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HTHongying Tang
Hongying Tang
XLXinyu Liu
Xinyu Liu
SCSi Chen
Si Chen
Xiaojun YuXiaojun Yu
Xiaojun Yu
YLYuemei Luo
Yuemei Luo
LLLinbo Liu
Linbo Liu
The refractive index of biological tissue is required for investigating the tissue's optical properties. Efforts have been made to characterize refractive indices of biological tissues at a single wavelength, but it is more convenient to know the Cauchy's coefficients, which provide refractive index over a wide range of wavelengths. We demonstrate a method to noninvasively provide the Cauchy's dispersion coefficients of biological tissues using micro-optical coherence tomography. Using short-frequency Fourier transforms, the relative optical thickness of the sample in the wavelength range of the broadband source was obtained from interferograms. The coefficients of Cauchy's equation were estimated based on the wavelength-dependent sample thickness. We validated the proposed method using distilled water and fresh rat cornea ex vivo, and the experimental results were consistent with the reference data.