Liansheng Zhang

Dr. Liansheng Zhang

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2024 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
ZFZuxi Feng
Zuxi Feng
MLMinjing Liao
Minjing Liao
LZLiansheng Zhang
Liansheng Zhang
Sex is a fundamental biological variable that influences immune system function, with sex chromosomes (X and Y) playing a central role in these differences. Despite substantial evidence of disparities in immune responses between males and females, biomedical research has historically overlooked sex as a critical factor. This oversight has contributed to the observed disparities in susceptibility to autoimmune diseases, infectious diseases, and malignancies between the sexes. In this review, we address the phenomena and mechanisms through which aberrant expression of sex chromosome-linked genes contributes to sex-based differences in immune responses. We specifically focus on the implications of X chromosome inactivation (XCI) escape and loss of Y chromosome (LOY). Our review aims to elucidate the molecular mechanisms driving these sex-based differences, with particular emphasis on the interactions between sex chromosome genes and immune cells in both males and females. Additionally, we discuss the potential impact of these differences on disease susceptibility and identify prospective therapeutic targets. As personalized and precision medicine advances, it is crucial to integrate sex differences into immunological research and clinical trials. We advocate for an increased focus on sex-based considerations in fundamental, translational, and clinical research to promote personalized, sex-specific healthcare.

1 January 2022 in Environmental Health and Preventive Medicine
Verified
Journal Article
Open access
PDF file
JBJun Bai
Jun Bai
LLLijuan Li
Lijuan Li
YLYanhong Li
Yanhong Li
LZLiansheng Zhang
Liansheng Zhang
Background: Tibetans have lived at very high altitudes for thousands of years, and have a distinctive suite of physiological traits that enable them to tolerate environmental hypoxia. Expanding awareness and knowledge of the differences in hematology, hypoxia-associated genes, immune system of people living at different altitudes and from different ethnic groups may provide evidence for the prevention of mountain sickness.Method: Ninety-five Han people at mid-altitude, ninety-five Tibetan people at high-altitude and ninety-eight Han people at high-altitude were recruited. Red blood cell parameters, immune cells, the contents of cytokines, hypoxia-associated gene single nucleotide polymorphisms (SNPs) were measured.Results: The values of Hematocrit (HCT), Mean cell volume (MCV) and Mean cell hemoglobin (MCH) in red blood cell, immune cell CD19+ B cell number, the levels of cytokines Erb-B2 receptor tyrosine kinase 3 (ErbB3) and Tumor necrosis factor receptor II (TNF-RII) and the levels of hypoxia-associated factors Hypoxia inducible factor-1α (HIF-1α), Hypoxia inducible factor-2α (HIF-2α) and HIF prolyl 4-hydroxylase 2 (PHD2) were decreased, while the frequencies of SNPs in twenty-six Endothelial PAS domain protein 1 (EPAS1) and Egl-9 family hypoxia inducible factor 1 (EGLN1) were increased in Tibetan people at high-altitude compared with that of Han peoples at high-altitude. Furthermore, compared with mid-altitude individuals, high-altitude individuals showed lower blood cell parameters including Hemoglobin concentration (HGB), HCT, MCV and MCH, higher Mean cell hemoglobin concentration (MCHC), lower immune cells including CD19+ B cells, CD4+ T cells and CD4/CD8 ratio, higher immune cells containing CD8+ T cells and CD16/56NK cells, decreased Growth regulated oncogene alpha (GROa), Macrophage inflammatory protein 1 beta (MIP-1b), Interleukin-8 (IL-8), and increased Thrombomodulin, downregulated hypoxia-associated factors including HIF1α, HIF2α and PHD2, and higher frequency of EGLN1 rs2275279.Conclusions: These results indicated that biological adaption to hypoxia at high altitude might have been mediated by changes in immune cells, cytokines, and hypoxia-associated genes during the evolutionary history of Tibetan populations. Furthermore, different responses to high altitude were observed in different ethnic groups, which may provide a useful knowledge to improve the protection of high-altitude populations from mountain sickness.

1 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RLRui-Jun Li
Rui-Jun Li
YLYing-Jun Lei
Ying-Jun Lei
ZCZhen-Xin Chang
Zhen-Xin Chang
LZLiansheng Zhang
Liansheng Zhang
Kuang-Chao FanKuang-Chao Fan
Kuang-Chao Fan
Low-frequency vibration is a harmful factor that affects the accuracy of micro/nano-measuring machines. Low-frequency vibration cannot be completely eliminated by passive control methods, such as the use of air-floating platforms. Therefore, low-frequency vibrations must be measured before being actively suppressed. In this study, the design of a low-cost high-sensitivity optical accelerometer is proposed. This optical accelerometer mainly comprises three components: a seismic mass, a leaf spring, and a sensing component based on a four-quadrant photodetector (QPD). When a vibration is detected, the seismic mass moves up and down due to the effect of inertia, and the leaf spring exhibits a corresponding elastic deformation, which is amplified by using an optical lever and measured by the QPD. Then, the acceleration can be calculated. The resonant frequencies and elastic coefficients of various seismic structures are simulated to attain the optimal detection of low-frequency, low-amplitude vibration. The accelerometer is calibrated using a homemade vibration calibration system, and the calibration experimental results demonstrate that the sensitivity of the optical accelerometer is 1.74 V (m·s−2)−1, the measurement range of the accelerometer is 0.003–7.29 m·s−2, and the operating frequencies range of 0.4–12 Hz. The standard deviation from ten measurements is under 7.9 × 10−4 m·s−2. The efficacy of the optical accelerometer in measuring low-frequency, low-amplitude dynamic responses is verified.

14 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYing-Jun Lei
Ying-Jun Lei
RLRui-Jun Li
Rui-Jun Li
LZLiansheng Zhang
Liansheng Zhang
HPHu Penghao
Hu Penghao
QHQiangxian Huang
Qiangxian Huang
Optical accelerometers are high-precision inertial sensors that use optical measurement technology to achieve high-precision and electromagnetic interference-resistant acceleration measurements. With the intensive research and development of optical accelerometers in recent years, their applications in inertial navigation, structural health monitoring, precision vibration isolation systems, wind turbine fault monitoring, earthquake monitoring, and other low-frequency vibration detection have flourished. Optical accelerometers have various schemes; however, their characteristics vary considerably due to different optical modulation schemes. This study aims to address the lack of systematic evaluation of currently available low-frequency optical accelerometers. Optical accelerometers can be classified into four categories in accordance with their optical modulation schemes: optical path-, optical intensity-, optical phase-, and optical wave-length-modulated accelerometers. The typical performance, advantages and disadvantages, and possible application scenarios of various optical accelerometers are summarized. This study also presents the current status and trends of low-frequency optical accelerometers in consideration of the growing demand for high-precision, low-frequency acceleration measurements.

1 September 2013 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
LZLiansheng Zhang
Liansheng Zhang
YLYong Bin Liu
Yong Bin Liu
CPCheng Liang Pan
Cheng Liang Pan
ZFZhi Hua Feng
Zhi Hua Feng

15 February 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
RLRui-Jun Li
Rui-Jun Li
YLYing-Jun Lei
Ying-Jun Lei
LZLiansheng Zhang
Liansheng Zhang
ZCZhen-Xin Chang
Zhen-Xin Chang
KFKuang-Chao Fan
Kuang-Chao Fan
HPHu Penghao
Hu Penghao
Low-frequency vibration is one of the harmful factors that affect the accuracy of micro-/nano-measuring machines because its amplitude is significantly small and it is very difficult to avoid. In this paper, a low-cost and high-precision vibration generator was developed to calibrate an optical accelerometer, which is self-designed to detect low-frequency vibration. A piezoelectric actuator is used as vibration exciter, a leaf spring made of beryllium copper is used as an elastic component, and a high-resolution, low-thermal-drift eddy current sensor is applied to investigate the vibrator’s performance. Experimental results demonstrate that the vibration generator can achieve steady output displacement with frequency range from 0.6 Hz to 50 Hz, an analytical displacement resolution of 3.1 nm and an acceleration range from 3.72 mm s −2 to 1935.41 mm s −2 with a relative standard deviation less than 1.79%. The effectiveness of the high-precision and low-cost vibration generator was verified by calibrating our optical accelerometer.