Various "scarless" approaches have been described for thyroid and parathyroid surgery. The objective of the current study was to investigate patients' perception of neck scar cosmesis, its impact on quality of life (QoL) and evaluate patient preference with regards to scar location. 120 patients undergoing thyroid or parathyroid surgery were followed-up over a 5-year period (2008-2013). Validated tools were used to assess scar perception and its impact on QoL. These were evaluated against sex, age, ethnicity, operation type, histopathology, time following surgery and scar length. Mean follow-up was 2.6 ± 3.8 years. One of the most common post-operative problems was scar-related (n = 18). Caucasian patients and those with benign histology expressed a lower impact on QoL (p < 0.001, p = 0.038). Sex and scar length did not significantly affect patients' perception for scar cosmesis (p > 0.05). Clinicians tended to score scar cosmesis higher than patients (p = 0.02). Most participants (75%) expressed a clear preference for an extracervical "scar-less in the neck" approach. Scar-related issues are frequently reported following thyroid and parathyroid surgery. The negative impact, often underestimated by clinicians, is more apparent amongst Asian and Afro-Caribbean patients and can significantly impact on their QoL. This, combined with the lack of correlation between scar length and patient satisfaction, indicates the need to divert research from miniaturising neck scars to concealing them in extracervical sites. Patients prefer a scar-less in the neck approach when given the option. A prospective comparative study is required to compare the cervical and extracervical approaches.
Cochlear implants restore hearing in patients with severe to profound deafness by delivering electrical stimuli inside the cochlea. Understanding stimulus current spread, and how it correlates to patient-dependent factors, is hampered by the poor accessibility of the inner ear and by the lack of clinically-relevant in vitro, in vivo or in silico models. Here, we present 3D printing-neural network co-modelling for interpreting electric field imaging profiles of cochlear implant patients. With tuneable electro-anatomy, the 3D printed cochleae can replicate clinical scenarios of electric field imaging profiles at the off-stimuli positions. The co-modelling framework demonstrated autonomous and robust predictions of patient profiles or cochlear geometry, unfolded the electro-anatomical factors causing current spread, assisted on-demand printing for implant testing, and inferred patients’ in vivo cochlear tissue resistivity (estimated mean = 6.6 kΩcm). We anticipate our framework will facilitate physical modelling and digital twin innovations for neuromodulation implants.
1 February 2014 in International Journal of Surgery
1. To investigate the feasibility of performing case-specific surgical rehearsal using a virtual reality temporal bone simulator. 2. To identify potential clinical applications in temporal bone surgery. Prospective assessment study. St Mary's Hospital, Imperial College NHS Trust, London UK. Sixteen participants consisting of a trainer and trainee group. Twenty-four cadaver temporal bones were CT-scanned and uploaded onto the Voxelman simulator. Sixteen participants performed a 90-min temporal bone dissection on the generic simulation model followed by 3 dissection tasks on the case simulation and cadaver models. Case rehearsal was assessed for feasibility. Clinical applications and usefulness were evaluated using a 5-point Likert-type scale. The upload process required a semi-automated system. Average time for upload was 20 min. Suboptimal reconstruction occurred in 21% of cases arising when the mastoid process and ossicular chain were not captured (n = 2) or when artefact was generated (n = 3). Case rehearsal rated highly (Likert score >4) for confidence (75%), facilitating planning (75%) and training (94%). Potential clinical applications for case rehearsal include ossicular chain surgery, cochlear implantation and congenital anomalies. Case rehearsal of cholesteatoma surgery is not possible on the current platform due to suboptimal soft tissue representation. The process of uploading CT data onto a virtual reality temporal bone simulator to perform surgical rehearsal is feasible using a semi-automated system. Further clinical evaluation is warranted to assess the benefit of performing patient-specific surgical rehearsal in selected procedures.
Objectives: The primary aim was to measure the volume of the scala tympani (ST) and the length of the straight portion of the cochlear basal turn from micro-computed tomography (μCT) images. The secondary aim was to estimate the electrode insertion force based on cochlear size and insertion speed. Both of these objectives have a direct clinical relevance in robotic assisted cochlear implant (CI) surgery.Methods: The ST was segmented in thirty μCT datasets to create a three-dimensional (3D) model and calculate the ST volume. The diameter (A-value), the width (B-value), and the straight portion of the cochlear basal turn (S-value) were measured from the oblique coronal plane. Electrode insertion force was measured in ST models of two different sizes, by inserting FLEX24 (24 mm) and FLEX28 (28 mm) electrode arrays at five different speeds (0.1, 0.5, 1, 2, and 4 mm/s).Results: The mean A-, B-, and S-values measured from the 30 μCT datasets were 9.0 ± 0.5, 6.7 ± 0.4, and 6.9 mm ± 0.5, respectively. The mean ST volume was 34.2 μl ± 7 (range 23–50 μl). The ST volume increased linearly with an increase in A- and B-values (Pearson's coefficient r = 0.55 and 0.56, respectively). The A-value exhibited linear positive correlation with the B-value and S-value (Pearson's coefficient r = 0.64 and r = 0.66, respectively). In the smaller of the two ST models, insertion forces were higher across the range of insertion speeds during both array insertions, when compared to the upscaled model. Before the maximum electrode insertion depths, a trend toward lower insertion force for lower insertion speed and vice-versa was observed.Conclusion: It is important to determine pre-operative cochlear size as this seems to have an effect upon electrode insertion forces. Higher insertion forces were seen in a smaller sized ST model across two electrode array lengths, as compared to an upscaled larger model. The ST volume, which cannot be visualized on clinical CT, correlates with clinical cochlear parameters. This enabled the creation of an equation capable of predicting ST volume utilizing A- and B-values, thus enabling pre-operative prediction of ST volume.
This study aimed to assess training of Senior House Officer-grade equivalent doctors in postgraduate surgical training or service (SHO-DIPST) in surgical specialties across the United Kingdom (UK), against nationally agreed Joint Committee on Surgical Training Quality Indicators (JCST QIs). Specific recommendations are made, with a view to improving quality of training, workforce retention and recruitment to Higher Surgical Training. Prospective, observational, multicentre study conducted by the Association of Surgeons in Training, using the UK National Research Collaborative model. Any centres in the UK providing acute surgical services were eligible. SHO-DIPST with a permanent contract, on out-of-hours 'on-call rota' were included across four, one-week data capture periods (September to October 2016, February to March 2017). Adherence to five quality indicators was reported using descriptive statistics. P-values were calculated using Student's t-test for continuous data, with a 5% level of significance. 2569 SHO-DIPST were included from all ten surgical specialties in 141 NHS trusts across all 16 Local Education and Training Boards in the UK. 960 SHO-DIPST were in registered 'training' posts (37.3%). The median number of SHO-DIPST per rota was 7.0 (IQR 5.0-9.0). Adherence to the five included JCST QIs ranged from 6.0 to 53.1%. Only four SHO-DIPST posts across the study population met all five JCST QIs (0.3%). The total number of training sessions was higher for those in registered training posts (p < 0.001), with significant specialty and regional variation. Only four early years postgraduate surgical training posts in the UK meet nationally approved minimum quality standards. Specific recommendations are made to improve training in this cohort and to bolster recruitment and retention into Higher Surgical Training.