Gan G Redhi

Prof. Gan G Redhi


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 March 2019 in Heliyon
Verified
Journal Article
Open access
RCRajasekhar Chokkareddy
Rajasekhar Chokkareddy
GRGan G Redhi
Gan G Redhi
KTKarthick Thangavel
Karthick Thangavel
In this study, an innovative nanocomposite of multiwalled carbon nanotubes (MWCNTs), copper oxide nanoparticles (CuONPs) and lignin (LGN) polymer were successfully synthesized and used to modify the glassy carbon electrode for the determination of chlorogenic acid (CGA). Cyclic voltammetry (CV) emphasised a quasi-reversible, adsorption controlled and pH dependent electrode procedure. In cyclic voltammetry a pair of well distinct redox peaks of CGA were observed at the LGN-MWCNTs-CuONPs-GCE in 0.1 M phosphate buffer solution (PBS), at pH 2. The synthesized nanoparticles and nanocomposites were characterized by Fourier transformation infrared spectroscopy (FTIR), transmission electron microscopy (TEM) and x-ray diffraction (XRD) analyses. Differential pulse voltammetry (DPV) was applied to the anodic peak and used for the quantitative detection of CGA. Under optimal conditions, the proposed sensor showed linear responses from 5 μM to 50 μM, the linear regression equation Ipa (μA) = 2.6074 C-5.1027 (R2 = 0.995), whilst the limit of detection (LOD) and limit of quantifications (LOQ) were found to be 0.0125 μM and 0.2631 μM respectively. The LGN-MWCNTs-CuONPs-GCE were applied to detect the CGA in real coffee samples with the recovery ranging from 97 to 106 %. The developed sensor was successfully applied for the analysis of CGA content in the coffee samples. In addition, electrophilic, nucleophilic reactions and chlorogenic acid docking studies were carried out to better understand the redox mechanisms and were supported by density functional theory calculations.

1 October 2017 in International Journal of Electrochemical Science
Verified
Journal Article
Open access
RCRajasekhar Chokkareddy
Rajasekhar Chokkareddy
NBNatesh Kumar Bhajanthri
Natesh Kumar Bhajanthri
GRGan G Redhi
Gan G Redhi

1 October 2016 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
NBN.K. Bhajanthri
N.K. Bhajanthri
VAV.K. Arumugam
V.K. Arumugam
RCRajasekhar Chokkareddy
Rajasekhar Chokkareddy
GRGan G Redhi
Gan G Redhi

5 June 2017 in Biosensors
Verified
Journal Article
Open access
PDF file
RCRajasekhar Chokkareddy
Rajasekhar Chokkareddy
NBNatesh Kumar Bhajanthri
Natesh Kumar Bhajanthri
GRGan G Redhi
Gan G Redhi
In this present work, a glassy carbon electrode (GCE) was modified primarily with multiwalled carbon nanotubes (MWCNTs) and a composite of MWCNTs and titanium oxide nanoparticles (TiO2NPs). The enzyme horseradish peroxidase (HRP) was immobilized to enhance the sensing ability of GCE. The proposed biosensor was used for the sensitive determination of isoniazid (INZ) in various pharmaceutical samples. The electrochemical behaviour of the developed MWCNT-TiO2NPs-HRP-GCE biosensor was studied by using cyclic voltammetry (CV) and differential pulse voltammetric (DPV) techniques. Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), thermogravimetry (TGA) and transmission electron microscopy (TEM) techniques were used to characterize the developed sensor. Phosphate buffer solution (PBS) with pH 7 was used as supporting electrolyte in the present investigation. The cyclic voltammetric results revealed that the increment of anodic peak currents for the enzyme-induced sensor was almost 8-fold greater than that of a bare GCE. The DPV technique exhibited good limit of detection and limit of quantification values, viz., 0.0335 μM and 0.1118 μM, respectively. Moreover, the developed sensor showed long-lasting stability and repeatability without any interferents. This strongly indicates that the fabricated sensor shows outstanding electrochemical performance towards INZ, with excellent selectivity and sensitivity. The developed sensor was successfully applied to pharmaceutical samples and gave good percentages of recoveries.

6 November 2019 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
RCRajasekhar Chokkareddy
Rajasekhar Chokkareddy
NTNiranjan Thondavada
Niranjan Thondavada
NBNatesh Kumar Bhajanthri
Natesh Kumar Bhajanthri
GRGan G Redhi
Gan G Redhi
Schematic illustration of the steps involved in the preparation of an IL–NH2-Fe3O4NP–MWCNT-GCE for the electrochemical determination of AMP.