Tapas Mallick

Prof. Tapas Mallick

Environment and Sustainability Institute, University of Exeter, Penryn, Cornwall TR10 9FE, UK
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2021 in The Chemical Record
Verified
Journal Article
Open access
PDF file
SVSasireka Velusamy
Sasireka Velusamy
ANURAG ROYANURAG ROY
ANURAG ROY
Senthilarasu SundaramSenthilarasu Sundaram
Senthilarasu Sundaram
Tapas MallickTapas Mallick
Tapas Mallick
Textile wastewater heavy metal pollution has become a severe environmental problem worldwide. Metal ion inclusion in a dye molecule exhibits a bathochromic shift producing deeper but duller shades, which provides excellent colouration. The ejection of a massive volume of wastewater containing heavy metal ions such as Cr (VI), Pb (II), Cd (II) and Zn (II) and metal‐containing dyes are an unavoidable consequence because the textile industry consumes large quantities of water and all these chemicals cannot be combined entirely with fibres during the dyeing process. These high concentrations of chemicals in effluents interfere with the natural water resources, cause severe toxicological implications on the environment with a dramatic impact on human health. This article reviewed the various metal‐containing dye types and their heavy metal ions pollution from entryway to the wastewater, which then briefly explored the effects on human health and the environment. Graphene‐based absorbers, specially graphene oxide (GO) benefits from an ordered structured, high specific surface area, and flexible surface functionalization options, which are indispensable to realize a high performance of heavy metal ion removal. These exceptional adsorption properties of graphene‐based materials support a position of ubiquity in our everyday lives. The collective representation of the textile wastewater‘s effective remediation methods is discussed and focused on the GO‐based adsorption methods. Understanding the critical impact regarding the GO‐based materials established adsorption portfolio for heavy metal ions removal are also discussed. Various heavy‐metal ions and their pollutant effect, ways to remove such heavy metal ions and role of graphene‐based adsorbent including their demand, perspective, limitation, and relative scopes are discussed elaborately in the review.

1 February 2018 in Journal of Energy Storage
Verified
Journal Article
Closed access
KRK S Reddy
K S Reddy
VMVijay Mudgal
Vijay Mudgal
Tapas MallickTapas Mallick
Tapas Mallick

1 December 2017 in Applied Energy
Verified
Journal Article
Open access
SSS. Sharma
S. Sharma
LMLeonardo Micheli
Leonardo Micheli
WCWenlong Chang
Wenlong Chang
Asif TahirAsif Tahir
Asif Tahir
KRK S Reddy
K S Reddy
Tapas MallickTapas Mallick
Tapas Mallick
This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.Building-Integrated Concentrated Photovoltaics (BICPV) is based on Photovoltaic (PV) technology which experience a loss in their electrical efficiency with an increase in temperature that may also lead to their permanent degradation over time. With a global PV installed capacity of 303 GW, a nominal 10 °C decrease in their average temperature could theoretically lead to 15 GW increase in electricity production worldwide. Currently, there is a gap in the research knowledge concerning the effectiveness of the available passive thermal regulation techniques for BICPV, both individually and working in tandem. This paper presents a novel combined passive cooling solution for BICPV incorporating micro-fins, Phase Change Material (PCM) and Nanomaterial Enhanced PCM (n-PCM). This work was undertaken with the aim to assess the unreported to date benefits of introducing these solutions into BICPV systems and to quantify their individual as well as combined effectiveness. The thermal performance of an un-finned metallic plate was first compared to a micro-finned plate under naturally convective conditions and then compared with applied PCM and n-PCM. A designed and fabricated, scaled-down thermal system was attached to the electrical heaters to mimic the temperature profile of the BICPV. The results showed that the average temperature in the centre of the system was reduced by 10.7 °C using micro-fins with PCM and 12.5 °C using micro-fins with n-PCM as compared to using the micro-fins only. Similarly, the effect of using PCM and n-PCM with the un-finned surface demonstrated a temperature reduction of 9.6 °C and 11.2 °C respectively as compared to the case of natural convection. Further, the innovative 3-D printed PCM containment, with no joined or screwed parts, showed significant improvements in leakage control. The important thermophysical properties of the PCM and the n-PCM were analysed and compared using a Differential Scanning Calorimeter. This research can contribute to bridging the existing gaps in research and development of thermal regulation of BICPV and it is envisaged that the realised incremental improvement can be a potential solution to (a) their performance improvement and (b) longer life, thereby contributing to the environmental benefits

1 March 2019 in Renewable Energy
Verified
Journal Article
Open access
JDJoseph Day
Joseph Day
Senthilarasu SundaramSenthilarasu Sundaram
Senthilarasu Sundaram
Tapas MallickTapas Mallick
Tapas Mallick

1 May 2016 in Solar Energy Materials and Solar Cells
Verified
Journal Article
Open access
SSShivangi Sharma
Shivangi Sharma
Asif TahirAsif Tahir
Asif Tahir
KRK S Reddy
K S Reddy
Tapas MallickTapas Mallick
Tapas Mallick
Building-Integrated Concentrated Photovoltaic (BICPV) systems integrate easily into built environments, replacing building material, providing benefits of generating electricity at the point of use, allowing light efficacy within the building envelope and providing thermal management. This paper presents a novel experimental evaluation of phase change materials (PCM) to enhance performance of low-concentration BICPV system via thermal regulation. Previous studies have primarily focussed on temporal and spatial studies of PCM temperature within the BIPV systems but the current work also discusses the effect of PCM on electrical parameters of the BICPV systems. Due to the inadequacy of the earlier reported model, a new analytical model is proposed and implemented with the in-house controlled experiments. Paraffin wax based RT42 was used within an in-house designed and fabricated PCM containment. An indoor experiment was performed using highly collimated continuous light source at 1000Wm−2. Results show an increase in relative electrical efficiency by 7.7% with PCM incorporation. An average reduction in module centre temperature by 3.8°C was recorded in the BICPV–PCM integrated system as compared to the naturally ventilated system without PCM. Studies showed that PCM effectiveness varies with irradiance; an increase in relative electrical efficiency by 1.15% at 500Wm−2, 4.20% at 750Wm−2 and 6.80% at 1200Wm−2 was observed

1 August 2018 in International Journal of Thermal Sciences
Verified
Journal Article
Open access
SKSourav Khanna
Sourav Khanna
KRK S Reddy
K S Reddy
Tapas MallickTapas Mallick
Tapas Mallick