Yunbo Wei

Dr. Yunbo Wei

Liaoning University of Technology, Jinzhou, Liaoning, China
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2019 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
YWYunbo Wei
Yunbo Wei
Minjie WangMinjie Wang
Minjie Wang
DZDanyang Zhao
Danyang Zhao
HLHongxia Li
Hongxia Li
YJYifei Jin
Yifei Jin
How to improve stent mechanical properties is a key issue for designing biodegradable polymeric stents (BPSs). In this study, a new design method of BPS was proposed based on the force analysis of supporting rings and bridges during stent implantation, and a novel BPS called open C-shaped stent (OCS) with superior comprehensive mechanical properties was developed accordingly. The key mechanical properties including radial force, radial recoil, and axial foreshortening of the OCS have been comprehensively studied and compared with those of the Abbott BVS using finite element analysis (FEA). In addition, the effects of the stent geometries on these mechanical properties have also been discussed in detail. Besides, in vitro mechanical tests including stent expansion and planar compression experiments have been performed to verify the simulation results. Based on the FEA results, it is found that the radial force and radial recoil of the designed OCS are 30% higher and 24% lower than those of the BVS, respectively. Meanwhile, the OCS is not shortened during expansion. Radial force and radial recoil are mainly dependent on the supporting ring structure, and the utilization of designed unequal-height supporting ring (UHSR) can effectively improve these two properties. Axial foreshortening is mainly determined by the bridge geometry as well as the connecting position of the bridge with the adjacent supporting rings. It is feasible to improve the axial foreshortening by using the bridges with a curved structure and locating the connecting position in the middle of the straight section of the supporting elements. The rationality of the proposed OCS and the effectiveness of the finite element method have been verified by in vitro experiments.

17 January 2017 in Polymers
Verified
Journal Article
Open access
PDF file
HLHongxia Li
Hongxia Li
Xinyu WangXinyu Wang
Xinyu Wang
YWYunbo Wei
Yunbo Wei
TLTao Liu
Tao Liu
Junfeng GuJunfeng Gu
Junfeng Gu
YLYahua Liu
Yahua Liu
Biodegradable stents made of poly-l-lactic acid (PLLA) have a promising prospect thanks to high biocompatibility and a favorable biodegradation period. However, due to the low stiffness of PLLA, polymeric stents have a lower radial stiffness and larger foreshortening. Furthermore, a stent is a tiny meshed tube, hence, it is difficult to make a polymeric stent. In the present study, a finite element analysis-based optimization method combined with Kriging surrogate modeling is firstly proposed to optimize the stent structure and stent microinjection molding process, so as to improve the stent mechanical properties and microinjection molding quality, respectively. The Kriging surrogate models are constructed to formulate the approximate mathematical relationships between the design variables and design objectives. Expected improvement is employed to balance local and global search to find the global optimal design. As an example, the polymeric ART18Z stent was investigated. The mechanical properties of stent expansion in a stenotic artery and the molding quality were improved after optimization. Numerical results demonstrate the proposed optimization method can be used for the computationally measurable optimality of stent structure design and stent microinjection molding process.

8 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
YWYunbo Wei
Yunbo Wei
JBJiangeng Bai
Jiangeng Bai
HZHaitao Zhao
Haitao Zhao
RWRui Wang
Rui Wang
HLHongxia Li
Hongxia Li
Polylactic acid (PLA) has been widely used in the field of medical devices. However, few studies have been conducted on the extrusion molding of PLA micro tubes for the preparation of biodegradable vascular stents. In this paper, the extrusion die for PLA single-cavity micro tubes was designed and manufactured by micro-extrusion theory. Taking the outer diameter, wall thickness, wall thickness uniformity and ovality of micro tubes as the evaluation index, the influence of the main extrusion process parameters on the evaluation index was studied. The experimental results show that the outer diameter and wall thickness are significantly affected by screw speed, pulling speed and gas flow rate; extrusion process parameters have little influence on wall thickness uniformity and ovality within a certain range, which mainly depends on the processing accuracy and assembly accuracy of the extrusion die. However, excessively high screw speed and low gas flow rate have significant effects on ovality. Finally, according to the influence of extrusion process parameters on the evaluation index, a series of micro tubes that meet the design requirements are extruded and carved into vascular stent structures.

5 February 2025 in Polymers
Verified
Journal Article
Open access
PDF file
SLShiyong Li
Shiyong Li
YWYunbo Wei
Yunbo Wei
HLHongxia Li
Hongxia Li
Biodegradable polymer drug-loaded vascular stents are a typical and promising application in the field of invasive interventional therapy. The drug release process of drug-loaded vascular stents, as well as the drug concentration in the vascular wall and its change process, will affect the therapeutic effect of vascular stents on vascular stenosis. As a drug carrier, the degradation properties of the polymer will affect the drug release process. In this study, the drug release process from the biodegradable polymer stent and the drug delivery process in vascular lumens and intravascular walls were studied by using 3D finite element method, with the effect of the biodegradation behavior of polymer on the drug release process being considered. The effects of the initial drug concentration, stent geometry, and polymer degradation rate on the drug release and delivery process were investigated. The results showed that the initial drug concentration and the thickness of the polymer stent significantly affected the drug concentration in the middle layer of the vessel wall, but the initial drug concentration had no effect on the drug release duration. The degradation of the polymer causes its porosity to change with time, which affects the drug diffusion in polymer, and further affects the drug concentration in the vessel wall. The three-dimensional structure of the stent can affect the blood flow in the blood vessel, resulting in drug deposition near the struts, especially near the intersection of the support struts and the bridge struts.