Michael Craig Miller

Mr. Michael Craig Miller

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2018 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
MMMichael Craig Miller
Michael Craig Miller
PRPeggy S. Robinson
Peggy S. Robinson
CWChristopher Wagner
Christopher Wagner
DODaniel J. O'SHannessy
Daniel J. O'SHannessy
Cancer cells from solid tumors can enter the circulatory system and survive to subsequently form distant metastases. The CellSearch® system (Menarini‐Silicon Biosystems, Huntingdon Valley, PA) was the first, FDA‐cleared system that provided a reliable tool for the investigation of circulating tumor cells (CTCs), which have been shown to be strongly associated with poor survival and therapy failure. Since that time, a number of new technologies have been introduced to improve CTC detection and/or isolation for further characterization. The continued and growing interest in the “liquid biopsy” field has spurred the development of numerous different CTC technologies. However, selecting the most appropriate CTC platform for individual applications can be challenging. No consensus has yet been reached in the community regarding which liquid biopsy technology is optimal. Here, we introduce the Parsortix™ Cell Separation System (ANGLE North America, Inc., King of Prussia, PA), a microfluidic based technology that captures rare cells based on size and deformability, offers reproducibly high capture efficiency, and produces highly enriched, viable (viability dependent on preservative used) CTCs that are amenable to a multitude of downstream analyses, including the isolation and interrogation of single cells. © 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.

26 October 2022 in Cancers
Verified
Journal Article
Open access
PDF file
Evan N CohenEvan N Cohen
Evan N Cohen
GJGitanjali Jayachandran
Gitanjali Jayachandran
RMRichard George Moore
Richard George Moore
MCMassimo Cristofanilli
Massimo Cristofanilli
JLJulie E Lang
Julie E Lang
Naoto T UenoNaoto T Ueno
Naoto T Ueno
Circulating tumor cells (CTCs) captured from the blood of cancer patients may serve as a surrogate source of tumor material that can be obtained via a venipuncture (also known as a liquid biopsy) and used to better understand tumor characteristics. However, the only FDA-cleared CTC assay has been limited to the enumeration of surface marker–defined cells and not further characterization of the CTCs. In this study, we tested the ability of a semi-automated device capable of capturing and harvesting CTCs from peripheral blood based on cell size and deformability, agnostic of cell-surface markers (the Parsortix® PC1 System), to yield CTCs for evaluation by downstream techniques commonly available in clinical laboratories. The data generated from this study were used to support a De Novo request (DEN200062) for the classification of this device, which the FDA recently granted. As part of a multicenter clinical trial, peripheral blood samples from 216 patients with metastatic breast cancer (MBC) and 205 healthy volunteers were subjected to CTC enrichment. A board-certified pathologist enumerated the CTCs from each participant by cytologic evaluation of Wright-Giemsa-stained slides. As proof of principle, cells harvested from a concurrent parallel sample provided by each participant were evaluated using one of three additional evaluation techniques: molecular profiling by qRT-PCR, RNA sequencing, or cytogenetic analysis of HER2 amplification by FISH. The study demonstrated that the Parsortix® PC1 System can effectively capture and harvest CTCs from the peripheral blood of MBC patients and that the harvested cells can be evaluated using orthogonal methodologies such as gene expression and/or Fluorescence In Situ Hybridization (FISH).

7 August 2023 in Journal of Circulating Biomarkers
Verified
Journal Article
Open access
PDF file
ATAmy Templeman
Amy Templeman
MMMichael Craig Miller
Michael Craig Miller
MCMartin J. Cooke
Martin J. Cooke
DODaniel J. O'SHannessy
Daniel J. O'SHannessy
YGYuwaraj Gurung
Yuwaraj Gurung
APAnne-Sophie Pailhes-Jimenez
Anne-Sophie Pailhes-Jimenez
Introduction: The Parsortix® PC1 system, Food and Drug Administration (FDA) cleared for use in metastatic breast cancer (MBC) patients, is an epitope-independent microfluidic device for the capture and harvest of circulating tumor cells from whole blood based on cell size and deformability. This report details the analytical characterization of linearity, detection limit, precision, and reproducibility for this device. Methods: System performance was determined using K2-EDTA blood samples collected from self-declared healthy female volunteers (HVs) and MBC patients spiked with prelabeled cultured breast cancer cell lines (SKBR3, MCF7, or Hs578T). Samples were processed on Parsortix® PC1 systems and captured cells were harvested and enumerated. Results: The system captured and harvested live SKBR3, MCF7, and Hs578T cells and fixed SKBR3 cells linearly between 2 and ~100 cells, with average harvest rates of 69%, 73%, 79%, and 90%, respectively. To harvest ≥1 cell ≥95% of the time, the system required 3, 5 or 4 live SKBR3, MCF7 or Hs578T cells, respectively. Average harvest rates from precision studies using 5, 10, and ~50 live cells spiked into blood for each cell line ranged from 63.5% to 76.2%, with repeatability and reproducibility percent coefficient of variation (%CV) estimates ranging from 12.3% to 32.4% and 13.3% to 34.1%, respectively. Average harvest rates using ~20 fixed SKBR3 cells spiked into HV and MBC patient blood samples were 75.0% ± 16.1% (%CV = 22.3%) and 68.4% ± 14.3% (%CV = 21.1%), respectively. Conclusions: These evaluations demonstrate the Parsortix® PC1 system linearly and reproducibly harvests tumor cells from blood over a range of 1 to ~100 cells.

1 April 1995 in American Journal of Psychiatry
Verified
Journal Article
Closed access
MMMichael Craig Miller
Michael Craig Miller

1 January 2008
Verified
Reference Entry
Closed access
MMMichael Craig Miller
Michael Craig Miller

13 March 2026 in Clinical Journal of Obstetrics and Gynecology
Verified
Journal Article
Open access
PDF file
RMRichard George Moore
Richard George Moore
ESElaine Smith
Elaine Smith
YAYoungeun Armbuster
Youngeun Armbuster
MMMichael Craig Miller
Michael Craig Miller
GMGeralyn Messerlian
Geralyn Messerlian
ABAlexandra Blackman
Alexandra Blackman
Background: Currently, there are no accurate clinical biomarkers for the management of patients diagnosed with endometrial cancer. The biomarker HE4 is often overexpressed and found to be elevated in the serum of patients with endometrial cancers. Objective: The objective of this trial was to assess the utility of HE4 as a biomarker for monitoring patients with endometrial cancer.Methods: This was an IRB-approved trial utilizing residual serial serum samples from patients diagnosed with endometrial cancer. Clinical status was determined by a combination of physician assessment, physical exam, serum CA125 levels, and imaging. Two separate analyses were performed to assess changes in HE4 serum levels. The first method used a change of 25% over that of the previous serum HE4 value, and the second analysis employed a velocity of change calculation of serum HE4 levels over time.Results: A total of 92 patients providing 799 serum samples were identified for analysis. Using a ≥25.0% increase of serum HE4 levels as an indicator of disease recurrence or progression, HE4 had an accuracy of 81.9% and a negative predictive value of 91.4%. The velocity of change analysis an accuracy of 85.4% with a negative predictive value of 86.7%.Conclusion: HE4 is highly accurate for detecting disease recurrence or progression and is a valuable clinical tool for monitoring patients with endometrial cancer.