Anatoliy A. Gashev

Prof. Dr. Anatoliy A. Gashev

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2004 in Microcirculation
Verified
Journal Article
Closed access
PDF file
AGAnatoliy A. Gashev
Anatoliy A. Gashev
MDMichael J. Davis
Michael J. Davis
MDMichael Delp
Michael Delp
DZDavid C. Zawieja
David C. Zawieja
Objective: To evaluate lymphatic contractile activity in different regions of the lymphatic system in a single animal model (the rat thoracic duct, mesenteric, cervical, and femoral lymphatics) in response to changes in lymph pressure and flow.Methods: The systolic and diastolic diameters of isolated, cannulated, and pressurized lymphatic vessels were measured. Contraction frequency, ejection fraction, and fractional pump flow were determined. The influences of incrementally increased transmural pressure (from 1 to 9 cm H2O) and imposed flow (from 1 to 5 cm H2O transaxial pressure gradient) were investigated.Results: The authors determined regional differences in lymphatic contractility in response to pressure and imposed flow. They found the highest pumping (at the optimal pressure levels) in mesenteric lymphatics and lowest pumping in thoracic duct. All lymphatics had their optimal pumping conditions at low levels of transmural pressure. Different degrees of the flow‐induced inhibition of the pump were observed in the different types of lymphatics. During high flow, the active lymph pumps in thoracic duct and cervical lymphatics were almost completely abolished, whereas mesenteric and femoral lymphatics still exhibited significant active pumping.Conclusions: The active lymph pumps in different regions of the rat body express variable relative strengths and sensitivities that are predetermined by different hydrodynamic factors and regional outflow resistances in their respective locations.

6 September 2006 in The Journal of Physiology
Verified
Journal Article
Open access
OGOlga Yu. Gasheva
Olga Yu. Gasheva
DZDavid C. Zawieja
David C. Zawieja
AGAnatoliy A. Gashev
Anatoliy A. Gashev
The objectives of this study were to evaluate the physiological importance of the flow and shear generated by phasic contractions of lymphatic vessels and the mechanisms responsible for the influences of such shear on lymphatic pumping. Lymphatic segments of the rat thoracic duct were isolated, cannulated and pressurized. The diastolic diameters were measured in phasically non‐active segments. The diastolic and systolic diameters, half‐relaxation time (HRT), contraction frequency, ejection fraction and fractional pump flow were determined in phasically active segments. Since imposed flow was excluded, flow and shear occurred only as a result of the intrinsic contractions in phasically active segments whereas in phasically non‐active segments contraction‐generated flow and shear were absent. The influences of incrementally increased transmural pressure (from 1 to 5 cmH2O) were examined in control conditions and after NO synthase blockade (l‐NAME 10−4m) or cyclooxygenase blockade (indomethacin 10−5m). The spontaneous phasic contractions produced a flow‐dependent diastolic relaxation. This reduction of the lymphatic tone is a regulatory mechanism that maintains pumping in thoracic duct in an energy‐saving/efficient mode: it improves diastolic filling (enhanced lusitropy – lowering HRT), makes lymphatic contractions stronger (enhanced inotropy – higher contraction amplitude) and propels more fluid forward during each contraction (elevated ejection fraction) while decreasing contraction frequency (reduced chronotropy). The findings also demonstrated that the NO pathway, not the cyclooxygenase pathway is responsible for this reduction of lymphatic tone and is the prevailing pathway responsible for the self‐regulatory adjustment of thoracic duct pumping to changes in lymph flow pattern.

1 December 2002 in Annals of the New York Academy of Sciences
Verified
Journal Article
Closed access
PDF file
AGAnatoliy A. Gashev
Anatoliy A. Gashev

5 April 2011 in Microcirculation
Verified
Journal Article
Closed access
PDF file
TNTakashi Nagai
Takashi Nagai
EBEric A. Bridenbaugh
Eric A. Bridenbaugh
AGAnatoliy A. Gashev
Anatoliy A. Gashev

28 May 2008 in Annals of the New York Academy of Sciences
Verified
Journal Article
Closed access
PDF file
AGAnatoliy A. Gashev
Anatoliy A. Gashev

1 November 2011 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
TATony J. Akl
Tony J. Akl
TNTakashi Nagai
Takashi Nagai
GCGerard L. Coté
Gerard L. Coté
AGAnatoliy A. Gashev
Anatoliy A. Gashev
The objective of study was to evaluate the aging-associated changes, contractile characteristics of mesenteric lymphatic vessels (MLV), and lymph flow in vivo in male 9- and 24-mo-old Fischer-344 rats. Lymphatic diameter, contraction amplitude, contraction frequency, and fractional pump flow, lymph flow velocity, wall shear stress, and minute active wall shear stress load were determined in MLV in vivo before and after Nω-nitro-l-arginine methyl ester hydrochloride (l-NAME) application at 100 μM. The active pumping of the aged rat MLV in vivo was found to be severely depleted, predominantly through the aging-associated decrease in lymphatic contractile frequency. Such changes correlate with enlargement of aged MLV, which experienced much lower minute active shear stress load than adult vessels. At the same time, pumping in aged MLV in vivo may be rapidly increased back to levels of adult vessels predominantly through the increase in contraction frequency induced by nitric oxide (NO) elimination. Findings support the idea that in aged tissues surrounding the aged MLV, the additional source of some yet unlinked lymphatic contraction-stimulatory metabolites is counterbalanced or blocked by NO release. The comparative analysis of the control data obtained from experiments with both adult and aged MLV in vivo and from isolated vessel-based studies clearly demonstrated that ex vivo isolated lymphatic vessels exhibit identical contractile characteristics to lymphatic vessels in vivo.