Ju Tang

Prof. Ju Tang

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2017 in Discover Nano
Verified
Journal Article
Open access
PDF file
XZXiaoxing Zhang
Xiaoxing Zhang
HCHao Cui
Hao Cui
YGYingang Gui
Yingang Gui
JTJu Tang
Ju Tang
Carbon nanotubes (CNTs) have aroused extensive attentions as a new category of gas sensor materials owing to their outstanding performance for detecting specific gas among a variety of ones through diverse gas responses. This review summarizes the adsorption mechanism of CNTs and their properties related to the detection of sulfur hexafluoride (SF6) decomposed gases that generated in gas insulation switchgear (GIS) of power system. Their performances as sensors of both experimental analysis and theoretical calculation for various kinds of decomposed gases are summarized, and the further research trend on CNTs in the detection of SF6 decomposition components is also put forward.

1 July 2017 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
JTJu Tang
Ju Tang
MJMiao Jin
Miao Jin
FZFuping Zeng
Fuping Zeng
XZXiaoxing Zhang
Xiaoxing Zhang
RHRui Huang
Rui Huang
Scientific partial discharge (PD) severity evaluation is highly important to the safe operation of gas‐insulated switchgear. However, describing PD severity with only a few statistical features such as discharge time and discharge amplitude is unreliable. Hence, a deep‐learning neural network model called stacked sparse auto‐encoder (SSAE) is proposed to realise feature extraction from the middle layer with a small number of nodes. The output feature that is almost similar to the input PD information is produced in the model. The features extracted from PD data are then fed into a soft‐max classifier to be classified into one of four defined PD severity states. In addition, unsupervised greedy layer‐wise pre‐training and supervised fine‐tuning are utilised to train the SSAE network during evaluation. Results of testing and simulation analysis show that the features extracted by the SSAE model effectively characterise PD severity. The performance of the SSAE model, which possesses an average assessment accuracy of up to 92.2%, is better than that of the support vector machine algorithm based on statistical features. According to the tested number of SSAE layers and features and the training sample size, the SSAE model possesses good expansibility and can be useful in practical applications.

1 December 2015 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
FZFuping Zeng
Fuping Zeng
YDYulin Dong
Yulin Dong
JTJu Tang
Ju Tang
Partial discharge (PD) is an early manifestation of insulation fault that occurs in electrical equipment, which holds rich feature information used to insulation assessment. In this study, step voltage method was applied to investigate the PD development process of typical protrusion defects in gas‐insulated switchgear. Nine features were extracted to represent the deterioration degree of internal insulation. Fuzzy C means clustering was applied to solve the state centres. PD severity was divided into four states based on the PD developing process, and the harmfulness of each state was illustrated. Finally, adaptive objective weight technology based on the theory of maximising deviation was adopted, and two‐level fuzzy comprehensive evaluation (TL‐FCE) model was established to address the problem of the weight allocation of different features on the evaluation result. The experimental test has been conducted to test the validity and effectiveness of the model. It is proved that TL‐FCE owns good performance to assess PD severity, and it is more suitable to handle fuzzy boundary problems than support vector machine.

7 June 2017 in IEEJ Transactions on Electrical and Electronic Engineering
Verified
Journal Article
Closed access
PDF file
JTJu Tang
Ju Tang
SMShouxiao Ma
Shouxiao Ma
MZMingjun Zhang
Mingjun Zhang
ZLZhiyuan Liu
Zhiyuan Liu
XLXingxing Li
Xingxing Li

12 January 2017 in Plasma Chemistry and Plasma Processing
Verified
Journal Article
Closed access
PDF file
JTJu Tang
Ju Tang
XRXiajin Rao
Xiajin Rao
Kexin ZhuKexin Zhu
Kexin Zhu
WCWei Cai
Wei Cai
LCLin Cheng
Lin Cheng
CZChaohai Zhang
Chaohai Zhang

5 May 2017 in Energies
Verified
Journal Article
Open access
PDF file
MLMin Liu
Min Liu
JTJu Tang
Ju Tang
XLXin Liu
Xin Liu
QYQiang Yao
Qiang Yao
YMYulong Miao
Yulong Miao
Pulses with different amplitudes occur when an inner partial discharge fault exists in SF6-gas-insulated DC high-voltage electrical equipment. SF6 decomposes following complex physical and chemical processes. Discussing and quantifying the mathematical relationship of pulse discharge quantities to SF6 decomposition component characteristics is helpful to evaluate and predict the insulation fault severity and development trends in SF6-insulated DC equipment. Numerous simulation experiments on SF6 decomposition under positive DC partial discharge were performed on a needle-plane model. The DC partial discharge quantities of pulses are obtained, and decomposition characteristics based on the mechanism of SF6 decomposition are analyzed. Results show that generation, effective generation rate and concentration ratio c(SO2F2 + SOF4)/c(SOF2 + SO2) of components increase with partial discharge severity, and the first two act in the following order: SOF4 > SOF2 > SO2F2 > SO2 > CF4 when the discharge quantity level is higher than 238,957 pC. Finally, a coefficient matrix illustrates the mathematical effects of pulses with different discharge quantities on different SF6 decomposition components. The pulses whose discharge quantity is higher than 50 pC have obvious promotion effects on the formation of decomposition components, whereas the pulses whose discharge quantity lower than 50 pC decrease the positive promotion effects that large discharge pulses have on decomposition components. The higher the effective generation rates are, the greater the partial discharge severity is, and their change laws provide a new method to evaluate and predict insulation fault severity and development trends in DC SF6-insulated equipment with high reliability and detection stability.