Mg2SiO4 holds promise for its application in the microwave communication field due to its low dielectric constant and high Q×f value. However, its high negative τf and high sintering temperature limit its application in low-temperature co-fired ceramic (LTCC) devices. In this work, Li2TiO3 and CaTiO3 were introduced to improve the τf, and LiF was chosen to decrease the sintering temperature. According to XRD patterns and SEM micrographs, the ceramic systems displayed a complex-phase structure, and the microstructure was densified when CaTiO3 was added. All of the relative densities, dielectric constants, and Q×f values first increased and then decreased as the sintering temperature increased. The MLLC11.5 ceramics sintered at 800 °C could be obtained with the highest Q×f value of 54,581 GHz (at 8.06 GHz), εr of 14.13, and τf of + 5.81 ppm/°C. Furthermore, it was proven that the MLLC11.5 powders could be co-fired without any reaction with Ag powders at 800 °C, indicating its potential for LTCC application. The MLLC11.5 composition was used to prepare a GPS antenna and showed good prospects for its application in electronic communications.
Human cerebral oxygenation and hemodynamics can be estimated by cerebral oxygenation parameters. Functional near-infrared spectroscopy (fNIRS) can be used to measure the hemoglobin concentration index of brain tissue noninvasively and in real time. However, limited by cumbersome equipment, high price and uncomfortable wear, conventional fNIRS monitoring systems still cannot achieve continuous and long-term monitoring. In this work, a flexible and wearable long-term monitoring system is developed featured with cost efficiency, simple preparation and light weight (only 1.6 g), which consists of a pair of light-emitting diodes (LEDs) and a photodetector (PD). Triangular serpentine interconnectors are introduced to connect the functional elements, enabling the device to be stretched in multiple directions. The device can continuously work for 7 h and be subjected to 2000 cycles of bending loading, with less than 3% change in voltage value, 1.89% and 1.9% change in LED luminous power and 0.9% change in voltage value. Furthermore, the hand-gripping and breath-holding experiments show that the system can accurately measure the changes in hemoglobin concentration in accordance with the commercial device. The flexible fNIRS system presented here not only provides a simple preparation process but also offers new ideas for daily cerebral state monitoring and prolonged clinical monitoring.