Furqan Shah

Dr. Furqan Shah

Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, SE-405 30, Göteborg, Sweden

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Acta Biomaterialia
Verified
Journal Article
Open access
Furqan ShahFurqan Shah
Furqan Shah
Peter ThomsenPeter Thomsen
Peter Thomsen
APAnders Palmquist
Anders Palmquist
Complex physical and chemical interactions take place in the interface between the implant surface and bone. Various descriptions of the ultrastructural arrangement to various implant design features, ranging from solid and macroporous geometries to surface modifications on the micron-, submicron-, and nano- levels, have been put forward. Here, the current knowledge regarding structural organisation of the bone-implant interface is reviewed with a focus on solid devices, mainly metal (or alloy) intended for permanent anchorage in bone. Certain biomaterials that undergo surface and bulk degradation are also considered. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin. In the published literature, as many as eight distinct arrangements of the bone-implant interface ultrastructure have been described. The interpretation is influenced by the in vivo model and species-specific characteristics, healing time point(s), physico-chemical properties of the implant surface, implant geometry, sample preparation route(s) and associated artefacts, analytical technique(s) and their limitations, and non-compromised vs compromised local tissue conditions. The understanding of the ultrastructure of the interface under experimental conditions is rapidly evolving due to the introduction of novel techniques for sample preparation and analysis. Nevertheless, the current understanding of the interface zone in humans in relation to clinical implant performance is still hampered by the shortcomings of clinical methods for resolving the finer details of the bone-implant interface. STATEMENT OF SIGNIFICANCE: Being a hierarchical material by design, the overall strength of bone is governed by composition and structure. Understanding the structure of the bone-implant interface is essential in the development of novel bone repair materials and strategies, and their long-term success. Here, the current knowledge regarding the eventual structural organisation of the bone-implant interface is reviewed, with a focus on solid devices intended for permanent anchorage in bone, and certain biomaterials that undergo surface and bulk degradation. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin.

1 May 2016 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
Furqan ShahFurqan Shah
Furqan Shah
Margarita TrobosMargarita Trobos
Margarita Trobos
Peter ThomsenPeter Thomsen
Peter Thomsen
APAnders Palmquist
Anders Palmquist

1 January 2016 in Acta Biomaterialia
Verified
Journal Article
Closed access
Furqan ShahFurqan Shah
Furqan Shah
ASAnders Snis
Anders Snis
Aleksandar MatićAleksandar Matić
Aleksandar Matić
Peter ThomsenPeter Thomsen
Peter Thomsen
APAnders Palmquist
Anders Palmquist

1 May 2016 in Acta Biomaterialia
Verified
Journal Article
Closed access
Furqan ShahFurqan Shah
Furqan Shah
OOOmar Omar
Omar Omar
FSFelicia Suska
Felicia Suska
ASAnders Snis
Anders Snis
Aleksandar MatićAleksandar Matić
Aleksandar Matić
APAnders Palmquist
Anders Palmquist

22 May 2019 in Bone Research
Verified
Journal Article
Open access
PDF file
Furqan ShahFurqan Shah
Furqan Shah
KRKrisztina Ruscsák
Krisztina Ruscsák
APAnders Palmquist
Anders Palmquist
Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair. The scanning electron microscope (SEM) is among the most frequently used instruments for examining bone. It offers the key advantage of very high spatial resolution coupled with a large depth of field and wide field of view. Interactions between incident electrons and atoms on the sample surface generate backscattered electrons, secondary electrons, and various other signals including X-rays that relay compositional and topographical information. Through selective removal or preservation of specific tissue components (organic, inorganic, cellular, vascular), their individual contribution(s) to the overall functional competence can be elucidated. With few restrictions on sample geometry and a variety of applicable sample-processing routes, a given sample may be conveniently adapted for multiple analytical methods. While a conventional SEM operates at high vacuum conditions that demand clean, dry, and electrically conductive samples, non-conductive materials (e.g., bone) can be imaged without significant modification from the natural state using an environmental scanning electron microscope. This review highlights important insights gained into bone microstructure and pathophysiology, bone response to implanted biomaterials, elemental analysis, SEM in paleoarchaeology, 3D imaging using focused ion beam techniques, correlative microscopy and in situ experiments. The capacity to image seamlessly across multiple length scales within the meso-micro-nano-continuum, the SEM lends itself to many unique and diverse applications, which attest to the versatility and user-friendly nature of this instrument for studying bone. Significant technological developments are anticipated for analysing bone using the SEM.

14 June 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Furqan ShahFurqan Shah
Furqan Shah
MJMartin L Johansson
Martin L Johansson
OOOmar Omar
Omar Omar
HSHanna Simonsson
Hanna Simonsson
APAnders Palmquist
Anders Palmquist
Peter ThomsenPeter Thomsen
Peter Thomsen
Osseointegrated implants inserted in the temporal bone are a vital component of bone-anchored hearing systems (BAHS). Despite low implant failure levels, early loading protocols and simplified procedures necessitate the application of implants which promote bone formation, bone bonding and biomechanical stability. Here, screw-shaped, commercially pure titanium implants were selectively laser ablated within the thread valley using an Nd:YAG laser to produce a microtopography with a superimposed nanotexture and a thickened surface oxide layer. State-of-the-art machined implants served as controls. After eight weeks’ implantation in rabbit tibiae, resonance frequency analysis (RFA) values increased from insertion to retrieval for both implant types, while removal torque (RTQ) measurements showed 153% higher biomechanical anchorage of the laser-modified implants. Comparably high bone area (BA) and bone-implant contact (BIC) were recorded for both implant types but with distinctly different failure patterns following biomechanical testing. Fracture lines appeared within the bone ~30–50 μm from the laser-modified surface, while separation occurred at the bone-implant interface for the machined surface. Strong correlations were found between RTQ and BIC and between RFA at retrieval and BA. In the endosteal threads, where all the bone had formed de novo, the extracellular matrix composition, the mineralised bone area and osteocyte densities were comparable for the two types of implant. Using resin cast etching, osteocyte canaliculi were observed directly approaching the laser-modified implant surface. Transmission electron microscopy showed canaliculi in close proximity to the laser-modified surface, in addition to a highly ordered arrangement of collagen fibrils aligned parallel to the implant surface contour. It is concluded that the physico-chemical surface properties of laser-modified surfaces (thicker oxide, micro- and nanoscale texture) promote bone bonding which may be of benefit in situations where large demands are imposed on biomechanically stable interfaces, such as in early loading and in compromised conditions.