Qian Cao

Qian Cao


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2024 in International Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
YGYing Gao
Ying Gao
RLRong-Xin Lu
Rong-Xin Lu
YTYun Tang
Yun Tang
XYXin-Yi Yang
Xin-Yi Yang
HMHu Meng
Hu Meng
QCQian Cao
Qian Cao
AIM: To investigate systemic immune-inflammation index (SII), neutrophil-to-lymphocyte ratio (NLR), and platelet-to-lymphocyte ratio (PLR) levels in patients with type 2 diabetes at different stages of diabetic retinopathy (DR). METHODS: This retrospective study included 141 patients with type 2 diabetes mellitus (DM): 45 without diabetic retinopathy (NDR), 47 with non-proliferative diabetic retinopathy (NPDR), and 49 with proliferative diabetic retinopathy (PDR). Complete blood counts were obtained, and NLR, PLR, and SII were calculated. The study analysed the ability of inflammatory markers to predict DR using receiver operating characteristic (ROC) curves. The relationships between DR stages and SII, PLR, and NLP were assessed using multivariate logistic regression. RESULTS: The average NLR, PLR, and SII were higher in the PDR group than in the NPDR group (P=0.011, 0.043, 0.009, respectively); higher in the NPDR group than in the NDR group (P<0.001 for all); and higher in the PDR group than in the NDR group (P<0.001 for all). In the ROC curve analysis, the NLR, PLR, and SII were significant predictors of DR (P<0.001 for all). The highest area under the curve (AUC) was for the PLR (0.929 for PLR, 0.925 for SII, and 0.821 for NLR). Multivariate regression analysis indicated that NLR, PLR, and SII were statistically significantly positive and independent predictors for the DR stages in patients with DM [odds ratio (OR)=1.122, 95% confidence interval (CI): 0.200–2.043, P<0.05; OR=0.038, 95%CI: 0.018–0.058, P<0.05; OR=0.007, 95%CI: 0.001–0.01, P<0.05, respectively). CONCLUSION: The NLR, PLR, and SII may be used as predictors of DR.

18 May 2023 in International Journal of Ophthalmology
Verified
Journal Article
Closed access
YCYueqin Chen
Yueqin Chen
JSJiawei Shen
Jiawei Shen
XZXiaoran Zhang
Xiaoran Zhang
WGWeiping Gao
Weiping Gao
QCQian Cao
Qian Cao
CXChunyan Xue
Chunyan Xue
AIM: To examine the protection of ferulic acid (FA) against ionizing radiation (IR)-induced lens injury in rats, as well as the underlying mechanisms. METHODS: FA (50 mg/kg) was administered to rats for 4 consecutive days before they were given 10 Gy γ-radiation, as well as for 3 consecutive days afterward. Two weeks after radiation, the eye tissues were collected. Histological alterations were evaluated by hematoxylin-eosin staining. Enzyme linked immunosorbent assay (ELISA) was utilized to assess the activities of glutathione reductase (GR) and superoxide dismutase (SOD), as well as the levels of glutathione (GSH) and malondialdehyde (MDA) in the lenses. The protein and mRNA levels of Bcl-2, caspase-3, Bax, heme oxygenase-1 (HO-1), and glutamate-cysteine ligase catalytic subunit (GCLC) were quantified using Western blot and quantitative reverse transcription polymerase chain reaction, respectively. With nuclear extracts, the nuclear factor erythroid-2 related factor (Nrf2) protein expressions in the nuclei were also measured. RESULTS: Rats exposed to IR showed lens histological alterations which could be alleviated by FA. FA treatment reversed apoptosis-related markers in IR-induced lens, as evidenced by lower levels of Bax and caspase-3 and higher level of Bcl-2. Furthermore, IR induced oxidative damage manifested by decreased GSH level, increased MDA level, and decreased SOD and GR activities. FA boosted nuclear translocation of Nrf2 and increased the expressions of HO-1 and GCLC to inhibit oxidative stress, as evidenced by an increase in GSH, a decrease in MDA, and an increase in GR and SOD activities. CONCLUSION: FA may work well in preventing and treating IR-induced cataract through promoting the Nrf2 signal pathway to attenuate oxidative damage and cell apoptosis.

10 May 2023 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
XZXiaoran Zhang
Xiaoran Zhang
JSJiawei Shen
Jiawei Shen
ZKZhen Kang
Zhen Kang
ACAndrew Chen
Andrew Chen
QCQian Cao
Qian Cao
CXChunyan Xue
Chunyan Xue
Purpose: To demonstrate the practicability of a portable instrument in assessing tear film breakup time (TFBUT): a lens attachment for smartphones (LAS). Methods: By applying LAS in combination with the iPhone 12 pro, and a recordable slit-lamp microscope, we obtained TFBUT videos from 58 volunteers. The comparison between the conventional slit-lamp microscope and LAS by an experienced ophthalmologist. Moreover, we also invited an ophthalmic postgraduate student and an undergraduate student with no clinical experience to assess TFBUT in those videos. The inter-observer reliability was assessed using intraclass correlation coefficients (ICC). Results: The TFBUT of 116 eyes in total was recorded. Reliability indexes were adequate. The Spearman’s correlation analysis and the intraclass correlation coefficient suggested a strong correlation between the 2 modalities (Right eye: Spearman’s r = 0.929, 95% confidence interval (CI) = 0.847–0.963, ICC = 0.978, p < 0.001; Left eye: Spearman’s r = 0.931, 95% CI = 0.866–0.964, ICC = 0.985, p < 0.001;). Between instruments, the majority of TFBUT measurements showed good agreement on Bland Altman plot. A high concordance was observed in TFBUT, when assessed by an ophthalmologist and an ophthalmic postgraduate student (Left eye: LAS ICC = 0.951, p < 0.001; Left eye: slit-lamp microscope ICC = 0.944, p < 0.001). Conclusions: Compared with the conventional slit-lamp microscope, the LAS has sufficient validity for evaluating TFBUT in clinics or at home.

15 December 2022 in Research Square
Verified
Preprint
Open access
PDF file
XZXiaoran Zhang
Xiaoran Zhang
JSJiawei Shen
Jiawei Shen
ZKZhen Kang
Zhen Kang
ACAndrew Chene
Andrew Chene
QCQian Cao
Qian Cao
CXChunyan Xue
Chunyan Xue
Purpose To demonstrate the practicability of a portable instrument in assessing tear film breakup time (TFBUT): a lens attachment for smartphones (LAS). Methods By applying LAS in combination with the iPhone 12 pro, and a recordable slit-lamp microscope, we obtained TFBUT videos from 58 volunteers. The comparison between the conventional slit-lamp microscope and LAS by an experienced ophthalmologist. Moreover, we also invited an ophthalmic postgraduate student and an undergraduate student with no clinical experience to assess TFBUT in those videos. The inter-observer reliability was assessed using intraclass correlation coefficients (ICC). Results The TFBUT of 116 eyes in total was recorded. Reliability indexes were adequate. The Spearman’s correlation analysis suggested a strong correlation between the 2 modalities (Spearman’s r = 0.941, 95% confidence interval [CI] = 0.906–0.963). The average intraclass correlation coefficient showed a substantial agreement among the 3 observers (LAS ICC = 0.911, p < 0.005; slit-lamp microscope ICC = 0.895, p < 0.005). A high concordance was observed in TFBUT, when assessed by an ophthalmologist and an ophthalmic postgraduate student (LAS ICC = 0.949, p < 0.005; slit-lamp microscope ICC = 0.940, p < 0.005). Conclusions Compared with the conventional slit-lamp microscope, the LAS has sufficient validity for evaluating TFBUT in clinics or at home.